MENTOR MemoryGel Breast Implant 3544001Recalls & reported problems

Mentor Texas L.P. · SILTEX Round Moderate Plus Profile Gel-Filled Breast Implant, 400cc |Textured|Round|Silicone| · Class 3 · Implant

All models of MENTOR MemoryGel Breast Implants (368) · MENTOR MemoryGel Breast Implant (211)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Mentor MemoryGel breast implant is a silicone gel-filled implant. Most of the 126 reports describe implants rupturing, and many describe capsular contracture, where scar tissue tightens around the implant, along with deformity. The reports include no deaths and 126 injuries. Reports fell to 5 in the last 12 months from 9 in the previous 12. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
126
Deaths reported
0
Injuries reported
126
Recalls naming it
0

Summary

The FDA's MAUDE database contains 126 adverse event reports that list this exact device (DI 00081317000907), received between May 4, 2018 and Sep 6, 2026 — classified as 126 injuries.

The most frequently reported specific device problem is “Material Rupture” (72 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 3 reportsDec 2023: 4 reportsJan 2024: 0 reportsFeb 2024: 2 reportsMar 2024: 2 reportsApr 2024: 3 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 4 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 2 reportsJun 2025: 2 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 4 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Rupture72
  • Adverse Event Without Identified Device or Use Problem62
  • Appropriate Device Problem Term/Code Not Available3
  • Migration3
  • Defective Device2
  • No Apparent Adverse Event2
  • Use of Device Problem1

Patient problems

  • Capsular Contracture56
  • Deformity/ Disfigurement38
  • No Code Available30
  • Granuloma10
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available8
  • Pain7
  • Seroma7
  • Breast Discomfort/Pain5

Recent adverse event reports

The 25 most recent of 126 reports, in the reporter's own words as published by the FDA.

  • InjurySep 6, 2026Material Rupture

    Patient problems: Deformity/ Disfigurement

    MAUDE report 50641445 ↗
  • InjuryDec 29, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT IMPLANTED WITH TWO 400CC MENTOR MEMORYGEL BREAST IMPLANT EXPERIENCED BILATERAL RUPTURES AND GRANULOMA POST-OPERATIVELY. AS A RESULT, THE PATIENT UNDERWENT EXPLANTATION ON (B)(6) 2026.

    Patient problems: Granuloma

    MAUDE report 23911275 ↗
  • InjuryDec 29, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT IMPLANTED WITH TWO 400CC MENTOR MEMORYGEL BREAST IMPLANT EXPERIENCED BILATERAL RUPTURES AND GRANULOMA POST-OPERATIVELY. AS A RESULT, THE PATIENT UNDERWENT EXPLANTATION ON (B)(6) 2026.

    Patient problems: Capsular Contracture; Granuloma

    MAUDE report 23911274 ↗
  • InjuryDec 9, 2025Material Rupture; Adverse Event Without Identified Device or Use Problem; Material Rupture; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A PATIENT UNDERWENT BREAST AUGMENTATION REVISION WITH TWO 400CC MENTOR MEMORYGEL BREAST IMPLANTS. POST-OPERATIVELY, THE PATIENT DEVELOPED BILATERAL BREAST CAPSULAR CONTRACTURES (BAKER GRADES I-II), RIGHT BREAST IMPLANT RUPTURE, LUMP IN ARMPIT, FATIGUE, AND BREAST IMPLANT ILLNESS. AT THE TIME OF THIS REPORT, MENTOR HAS RECEIVED NO INFORMATION REGARDING EXPLANTATION OR AN EXPECTED EXPLANTATION DATE. THIS MEDWATCH FORM IS FOR THE LEFT BREAST PROSTHESIS.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Capsular Contracture

    MAUDE report 23763719 ↗
  • InjuryDec 9, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT UNDERWENT BREAST AUGMENTATION REVISION WITH TWO 400CC MENTOR MEMORYGEL BREAST IMPLANTS. POST-OPERATIVELY, THE PATIENT DEVELOPED BILATERAL BREAST CAPSULAR CONTRACTURES (BAKER GRADES I-II), RIGHT BREAST IMPLANT RUPTURE, LUMP IN ARMPIT, FATIGUE, AND BREAST IMPLANT ILLNESS. AT THE TIME OF THIS REPORT, MENTOR HAS RECEIVED NO INFORMATION REGARDING EXPLANTATION OR AN EXPECTED EXPLANTATION DATE. THIS MEDWATCH FORM IS FOR THE RIGHT BREAST PROSTHESIS.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Capsular Contracture

    MAUDE report 23763715 ↗
  • InjuryJul 1, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A PATIENT WHO UNDERWENT A BREAST AUGMENTATION REVISION PROCEDURE WITH A MENTOR MEMORYGEL BREAST IMPLANT 400CC GEL BREAST PROSTHESIS DEVELOPED BAKER GRADE IV CAPSULAR CONTRACTURE IN HER LEFT BREAST POST IMPLANTATION. AS A RESULT, THE PATIENT IS SCHEDULED TO UNDERGO EXPLANTATION ON (B)(6) 2025.

    Patient problems: Capsular Contracture

    MAUDE report 22378367 ↗
  • InjuryJun 10, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT UNDERWENT PRIMARY BREAST AUGMENTATION WITH TWO 400CC MENTOR MEMORYGEL BREAST IMPLANTS. POST-OPERATIVELY, THE PATIENT SUFFERED BILATERAL BREAST IMPLANT RUPTURES AFTER UNDERGOING A MAMMOGRAM. AT THE TIME OF THIS REPORT, MENTOR HAS RECEIVED NO INFORMATION REGARDING EXPLANTATION OR AN EXPECTED EXPLANTATION DATE. THIS MEDWATCH FORM IS FOR THE RIGHT BREAST PROSTHESIS.

    Patient problems: Deformity/ Disfigurement

    MAUDE report 22173547 ↗
  • InjuryJun 10, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT UNDERWENT PRIMARY BREAST AUGMENTATION WITH TWO 400CC MENTOR MEMORYGEL BREAST IMPLANTS. POST-OPERATIVELY, THE PATIENT SUFFERED BILATERAL BREAST IMPLANT RUPTURES AFTER UNDERGOING A MAMMOGRAM. AT THE TIME OF THIS REPORT, MENTOR HAS RECEIVED NO INFORMATION REGARDING EXPLANTATION OR AN EXPECTED EXPLANTATION DATE. THIS MEDWATCH FORM IS FOR THE LEFT BREAST PROSTHESIS.

    Patient problems: Deformity/ Disfigurement

    MAUDE report 22173542 ↗
  • InjuryMay 22, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT UNDERWENT BREAST AUGMENTATION REVISION WITH TWO 400CC MENTOR MEMORYGEL BREAST IMPLANTS. POST-OPERATIVELY, THE PATIENT SUFFERED BILATERAL BREAST IMPLANT RUPTURES. AT THE TIME OF THIS REPORT, MENTOR HAS RECEIVED NO INFORMATION REGARDING EXPLANTATION OR AN EXPECTED EXPLANTATION DATE. THIS MEDWATCH FORM IS FOR THE LEFT BREAST PROSTHESIS.

    Patient problems: Breast Mass; Deformity/ Disfigurement; Pain

    MAUDE report 22073667 ↗
  • InjuryMay 22, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT UNDERWENT BREAST AUGMENTATION REVISION WITH TWO 400CC MENTOR MEMORYGEL BREAST IMPLANTS. POST-OPERATIVELY, THE PATIENT SUFFERED BILATERAL BREAST IMPLANT RUPTURES. AT THE TIME OF THIS REPORT, MENTOR HAS RECEIVED NO INFORMATION REGARDING EXPLANTATION OR AN EXPECTED EXPLANTATION DATE. THIS MEDWATCH FORM IS FOR THE RIGHT BREAST PROSTHESIS.

    Patient problems: Deformity/ Disfigurement

    MAUDE report 22073665 ↗
  • InjuryFeb 11, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT UNDERWENT A PRIMARY BREAST AUGMENTATION SURGERY WITH IMPLANTATION OF A 400CC MENTOR MEMORYGEL BREAST IMPLANT PROSTHESIS. POST-OPERATIVELY, THE PATIENT WAS DIAGNOSED WITH BILATERALLY RUPTURED BREAST IMPLANTS DURING A PHYSICAL EXAM WITH A MEDICAL PROFESSIONAL. AS A RESULT, THE PATIENT UNDERWENT BILATERAL REMOVAL AND REPLACEMENT WITH 400CC MENTOR MEMORYGEL XTRA BREAST IMPLANTS ON (B)(6) 2025.

    Patient problems: Deformity/ Disfigurement

    MAUDE report 21356584 ↗
  • InjuryFeb 11, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT UNDERWENT A PRIMARY BREAST AUGMENTATION SURGERY WITH IMPLANTATION OF A 400CC MENTOR MEMORYGEL BREAST IMPLANT PROSTHESIS. POST-OPERATIVELY, THE PATIENT WAS DIAGNOSED WITH BILATERALLY RUPTURED BREAST IMPLANTS DURING A PHYSICAL EXAM WITH A MEDICAL PROFESSIONAL. AS A RESULT, THE PATIENT UNDERWENT BILATERAL REMOVAL AND REPLACEMENT WITH 400CC MENTOR MEMORYGEL XTRA BREAST IMPLANTS ON (B)(6) 2025.

    Patient problems: Deformity/ Disfigurement

    MAUDE report 21356582 ↗
  • InjuryFeb 4, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT WHO UNDERWENT PRIMARY BREAST AUGMENTATION WITH 400CC MENTOR MEMORYGEL BREAST IMPLANTS EXPERIENCED BILATERAL CAPSULAR CONTRACTURE AND RIGHT SIDED RUPTURE POST PROCEDURE. THIS WAS ACCOMPANIED BY PAIN AND ASYMMETRY. FUTURE EXPLANT IS INDICATED, HOWEVER, AT THE TIME OF THIS REPORT, MENTOR HAS RECEIVED NO INFORMATION REGARDING AN EXPECTED EXPLANTATION DATE.

    Patient problems: Capsular Contracture

    MAUDE report 21307268 ↗
  • InjuryFeb 4, 2025Material Rupture; Adverse Event Without Identified Device or Use Problem; Material Rupture; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A PATIENT WHO UNDERWENT PRIMARY BREAST AUGMENTATION WITH 400CC MENTOR MEMORYGEL BREAST IMPLANTS EXPERIENCED BILATERAL CAPSULAR CONTRACTURE AND RIGHT SIDED RUPTURE POST PROCEDURE. THIS WAS ACCOMPANIED BY PAIN AND ASYMMETRY. FUTURE EXPLANT IS INDICATED, HOWEVER, AT THE TIME OF THIS REPORT, MENTOR HAS RECEIVED NO INFORMATION REGARDING AN EXPECTED EXPLANTATION DATE.

    Patient problems: Capsular Contracture

    MAUDE report 21307263 ↗
  • InjuryOct 14, 2024Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT UNDERWENT A PRIMARY BREAST AUGMENTATION SURGERY WITH IMPLANTATION OF A 400CC MENTOR MEMORYGEL BREAST IMPLANT PROSTHESIS. POST-OPERATIVELY, THE PATIENT UNDERWENT BILATERAL REMOVAL AND REPLACEMENT WITH 190CC (LEFT-SIDED) AND 275CC (RIGHT-SIDED) MENTOR MEMORYGEL BREAST IMPLANTS ON (B)(6) 2024. HOWEVER, DURING THE REVISION SURGERY, BILATERALLY RUPTURED BREAST IMPLANT WERE DISCOVERED. THERE WAS NO REPORTED PROCEDURAL DELAY OR PATIENT CONSEQUENCES DUE TO THE DISCOVERY. THIS REPORT IS FOR THE LEFT BREAST PROSTHESIS.

    Patient problems: Deformity/ Disfigurement

    MAUDE report 20446730 ↗
  • InjuryJun 18, 2024Use of Device Problem; Migration; Use of Device Problem; Migration

    IT WAS REPORTED THAT A CAUCASIAN FEMALE PATIENT UNDERWENT A BREAST SURGERY WITH A 400CC MENTOR MEMORYGEL BREAST IMPLANT AND EXPERIENCED DEVICE MIGRATION ON THE LEFT SIDE POST-OPERATIVELY, WHICH WAS DIAGNOSED IN THE PATIENT'S PREOPERATIVE DIAGNOSIS. AS A RESULT, THE PATIENT UNDERWENT SURGICAL INTERVENTION (CAPSULORRHAPHY AND REPOSITION OF THE IMPLANT AND EXCISION OF EXCESS STRATTICE CAUDALLY AND SKIN CAUDALLY) ON (B)(6), 2024. IT WAS REPORTED THAT THE BREAST PROSTHESIS WAS RE-IMPLANTED INTO THE PATIENT. CODE A23 HAS BEEN ADDED TO SECTION H6-MEDICAL DEVICE PROBLEM CODE AS THIS IS CONSIDERED USER ERROR.

    Patient problems: Deformity/ Disfigurement

    MAUDE report 19564037 ↗
  • InjuryApr 25, 2024Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT WHO UNDERWENT PRIMARY BREAST AUGMENTATION WITH A 400CC MENTOR MEMORYGEL BREAST IMPLANT EXPERIENCED LEFT SIDED RUPTURE POST PROCEDURE. THE RUPTURE WAS DIAGNOSED THROUGH MAGNETIC RESONANCE IMAGING. AS A RESULT, EXPLANT WAS PERFORMED ON (B)(6) 2024.

    Patient problems: Deformity/ Disfigurement

    MAUDE report 19183221 ↗
  • InjuryApr 22, 2024Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT UNDERWENT PRIMARY BREAST AUGMENTATION WITH A 400CC MENTOR MEMORYGEL BREAST IMPLANT ON THE RIGHT BREAST. POST-OPERATIVELY, THE PATIENT SUFFERED RIGHT BREAST IMPLANT RUPTURE. AS A RESULT, THE PATIENT UNDERWENT BILATERAL BREAST IMPLANT REMOVAL AND REPLACEMENT SURGERY ON (B)(6) 2024. THE REPLACEMENT DEVICES WERE: (RIGHT) 475CC MENTOR MEMORYGEL BREAST IMPLANT CATALOG: 3504754BC LOT: 9935602 SN: (B)(6), AND (LEFT) 475CC MENTOR MEMORYGEL BREAST IMPLANT CATALOG: 3504754BC LOT: 9935602 SN: (B)(6).

    Patient problems: Deformity/ Disfigurement

    MAUDE report 19159552 ↗
  • InjuryApr 12, 2024Adverse Event Without Identified Device or Use Problem; Appropriate Device Problem Term/Code Not Available; Adverse Event Without Identified Device or Use Problem; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED VIA MW5152198 THAT A PATIENT IMPLANTED WITH TWO 400CC MENTOR MEMORYGEL BREAST IMPLANT EXPERIENCED SYMPTOMS INCLUDING BREAST IMPLANT ILLNESS, DEBILITATING HEALTH ISSUES, VISION ISSUES, FATIGUE, BRAIN FOG, HIGH PROLACTIN, LOW THYROID FUNCTION, LOW HORMONES, HIGH RHEUMATOID FACTOR POST-OPERATIVELY. AS A RESULT, THE PATIENT UNDERWENT EXPLANTATION ON (B)(6) 2024. THIS REPORT IS FOR THE FIRST OF TWO DEVICES.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Capsular Contracture

    MAUDE report 19098079 ↗
  • InjuryMar 19, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A FEMALE PATIENT WHO UNDERWENT A BREAST AUGMENTATION PRIMARY WITH AN UNKNOWN MENTOR SILICONE BREAST IMPLANT EXPERIENCED RIGHT-SIDED CAPSULAR CONTRACTURE GRADE III POSTOPERATIVE. THE ISSUE WAS DIAGNOSED THROUGH IN OFFICE EXAMINATION. AS A RESULT, PATIENT UNDERWENT REPLACEMENT WITH UNSPECIFIED IMPLANTS ON (B)(6) 2024.

    Patient problems: Capsular Contracture

    MAUDE report 18937694 ↗
  • InjuryMar 7, 2024Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT UNDERWENT A BREAST AUGMENTATION REVISION SURGERY WITH A 400CC MENTOR MEMORYGEL BREAST IMPLANT. POST-OPERATIVELY, THE PATIENT EXPERIENCED A RUPTURE OF HER LEFT PROSTHESIS, WHICH WAS CONFIRMED VIA ULTRASOUND. IT WAS ALSO REPORTED THAT THE PATIENT EXPERIENCED PAIN IN HER LEFT BREAST. AS A RESULT, THE PATIENT IS SCHEDULED FOR BILATERAL REMOVAL SURGERY ON (B)(6) 2024.

    Patient problems: Breast Discomfort/Pain

    MAUDE report 18859435 ↗
  • InjuryFeb 2, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A 33-YEAR-OLD CAUCASIAN FEMALE PATIENT UNDERWENT A PRIMARY BREAST AUGMENTATION WITH TWO 400CC MENTOR MEMORYGEL BREAST IMPLANTS AND EXPERIENCED BILATERAL CAPSULAR CONTRACTURE (BAKER GRADE UNKNOWN) POST-OPERATIVELY. IT WAS ALSO REPORTED THAT THE PATIENT EXPERIENCED GENERALIZED ILLNESS SYMPTOMS INCLUDING AMNONIA, UNSPECIFIED AUTOIMMUNE DISEASE, AND ANISOMASTIA. AT THE TIME OF THIS REPORT, MENTOR HAS RECEIVED NO INFORMATION REGARDING EXPLANTATION OR AN EXPECTED EXPLANTATION DATE. THIS REPORT IS FOR THE RIGHT SIDE DEVICE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Capsular Contracture

    MAUDE report 18634303 ↗
  • InjuryFeb 2, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A 33-YEAR-OLD CAUCASIAN FEMALE PATIENT UNDERWENT A PRIMARY BREAST AUGMENTATION WITH TWO 400CC MENTOR MEMORYGEL BREAST IMPLANTS AND EXPERIENCED BILATERAL CAPSULAR CONTRACTURE (BAKER GRADE UNKNOWN) POST-OPERATIVELY. IT WAS ALSO REPORTED THAT THE PATIENT EXPERIENCED GENERALIZED ILLNESS SYMPTOMS INCLUDING AMNONIA, UNSPECIFIED AUTOIMMUNE DISEASE, AND ANISOMASTIA. AT THE TIME OF THIS REPORT, MENTOR HAS RECEIVED NO INFORMATION REGARDING EXPLANTATION OR AN EXPECTED EXPLANTATION DATE. THIS REPORT IS FOR THE LEFT SIDE DEVICE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Capsular Contracture

    MAUDE report 18632749 ↗
  • InjuryDec 28, 2023Material Rupture; Adverse Event Without Identified Device or Use Problem; Material Rupture; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A 51-YEAR-OLD CAUCASIAN FEMALE PATIENT UNDERWENT A BREAST AUGMENTATION REVISION WITH TWO 400CC MENTOR MEMORYGEL BREAST IMPLANTS AND EXPERIENCED BILATERAL CAPSULAR CONTRACTURE (BAKER GRADE 3 ON THE RIGHT AND BAKER GRADE 2 ON THE LEFT) POST-OPERATIVELY. THE PATIENT MENTIONED THAT THE RIGHT SIDE ¿BUBBLED UP¿ AND LOOKED REALLY HIGH. THE PATIENT REPORTED SORENESS ON THE ARMPITS AND THE BODY BEING EXTREMELY SORE. AS A RESULT, THE PATIENT IS TO UNDERGO DEVICE EXPLANTATION ON (B)(6) 2024. THIS REPORT IS FOR THE LEFT SIDE DEVICE.

    Patient problems: Capsular Contracture

    MAUDE report 18411534 ↗
  • InjuryDec 28, 2023Material Rupture; Adverse Event Without Identified Device or Use Problem; Material Rupture; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A 51-YEAR-OLD CAUCASIAN FEMALE PATIENT UNDERWENT A BREAST AUGMENTATION REVISION WITH TWO 400CC MENTOR MEMORYGEL BREAST IMPLANTS AND EXPERIENCED BILATERAL CAPSULAR CONTRACTURE (BAKER GRADE 3 ON THE RIGHT AND BAKER GRADE 2 ON THE LEFT) POST-OPERATIVELY. THE PATIENT MENTIONED THAT THE RIGHT SIDE ¿BUBBLED UP¿ AND LOOKED REALLY HIGH. THE PATIENT REPORTED SORENESS ON THE ARMPITS AND THE BODY BEING EXTREMELY SORE. AS A RESULT, THE PATIENT IS TO UNDERGO DEVICE EXPLANTATION ON (B)(6) 2024. THIS REPORT IS FOR THE RIGHT SIDE DEVICE.

    Patient problems: Capsular Contracture

    MAUDE report 18411510 ↗

Other Prosthesis, breast, noninflatable, internal, silicone gel-filled devices

All Prosthesis, breast, noninflatable, internal, silicone gel-filled devices →