Skip to content

MENTOR MemoryShape Breast Implant 3341009Recalls & reported problems

Mentor Texas L.P. · Tall Height, Moderate Plus Profile Silicone Gel-Filled Breast Implant, 205cc |Textured|Contour|Silicone| · Class 3 · Implant

All models of MENTOR MemoryShape Breast Implant (65)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00081317005032), received between Apr 2, 2025 and Apr 2, 2025 — classified as 2 injuries.

The most frequently reported specific device problem is “Material Rupture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 2 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Material Rupture1

Patient problems

  • Capsular Contracture2
  • Pain1
  • Swollen Lymph Nodes/Glands1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 2, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT A PATIENT WHO UNDERWENT PRIMARY BREAST AUGMENTATION WITH 205CC MENTOR MEMORYSHAPE BREAST IMPLANTS EXPERIENCED RIGHT SIDED BAKER GRADE III CAPSULAR CONTRACTURE, LEFT SIDED RUPTURE, LEFT SIDED LYMPHADENOPATHY, AND LEFT SIDED PAIN POST PROCEDURE. SHE WAS HAVING NECK PAIN WITH SWOLLEN LYMPH NODES. AS A RESULT, EXPLANT WAS PERFORMED ON (B)(6) 2025.

    Patient problems: Capsular Contracture; Pain; Swollen Lymph Nodes/Glands

    MAUDE report 21753274 ↗
  • InjuryApr 2, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A PATIENT WHO UNDERWENT PRIMARY BREAST AUGMENTATION WITH 205CC MENTOR MEMORYSHAPE BREAST IMPLANTS EXPERIENCED RIGHT SIDED BAKER GRADE III CAPSULAR CONTRACTURE, LEFT SIDED RUPTURE, LEFT SIDED LYMPHADENOPATHY, AND LEFT SIDED PAIN POST PROCEDURE. SHE WAS HAVING NECK PAIN WITH SWOLLEN LYMPH NODES. AS A RESULT, EXPLANT WAS PERFORMED ON (B)(6) 2025.

    Patient problems: Capsular Contracture

    MAUDE report 21753272 ↗

Other Prosthesis, breast, noninflatable, internal, silicone gel-filled devices

All Prosthesis, breast, noninflatable, internal, silicone gel-filled devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page