Skip to content

MENTOR MemoryGel Breast Implant 3505185BCRecalls & reported problems

Mentor Texas L.P. · Smooth Round Ultra High Profile Silicone Gel-Filled Breast Implant, 185cc |Smooth|Round|Silicone| · Class 3 · Implant

All models of MENTOR MemoryGel Breast Implants (368) · MENTOR MemoryGel Breast Implant (211)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00081317006862), received between May 10, 2023 and Aug 24, 2026 — classified as 3 injuries.

The most frequently reported specific device problem is “Material Rupture” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Rupture3
  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Capsular Contracture1
  • Deformity/ Disfigurement1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 24, 2026Material Rupture

    It was reported that a patient underwent a breast augmentation revision procedure with a MENTOR MemoryGel Breast Implant gel breast prosthesis that ruptured post implantation. Rupture of the patient¿s left breast prosthesis was reported. As a result, the patient underwent explantation and replacement with a MENTOR MemoryGel Breast Implant gel breast prosthesis.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50418777 ↗
  • InjuryFeb 5, 2024Material Rupture; Material Rupture

    IT WAS REPORTED THAT A 66-YEAR-OLD CAUCASIAN FEMALE PATIENT UNDERWENT BREAST RECONSTRUCTION SURGERY WITH 185CC MENTOR MEMORYGEL BREAST IMPLANT AND EXPERIENCED BREAST IMPLANT RUPTURE ON HER LEFT SIDE POSTOPERATIVELY. MRI CONFIRMED THE RUPTURE. THE PATIENT HAS CONSULTED WITH THE HEALTHCARE PROFESSIONAL. AS A RESULT, THE PATIENT UNDERWENT LEFT SIDE REPLACEMENT SURGERY WITH CATALOG NUMBER 3505185BC; SERIAL NUMBER (B)(6) ON (B)(6) 2024.

    Patient problems: Deformity/ Disfigurement

    MAUDE report 18641626 ↗
  • InjuryMay 10, 2023Material Rupture; Adverse Event Without Identified Device or Use Problem; Material Rupture; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A 25-YEAR OLD CAUCASIAN FEMALE PATIENT UNDERWENT PRIMARY BREAST AUGMENTATION WITH A 185CC MENTOR MEMORYGEL BREAST IMPLANT ON THE LEFT BREAST. POST-OPERATIVELY, THE PATIENT WAS DIAGNOSED, VIA PHYSICAL EXAMINATION, WITH LEFT BREAST CAPSULAR CONTRACTURE (BAKER GRADE III) AND POSSIBLE LEFT BREAST IMPLANT RUPTURE. AT THE TIME OF THIS REPORT, MENTOR HAS RECEIVED NO INFORMATION REGARDING EXPLANTATION OR AN EXPECTED EXPLANTATION DATE.

    Patient problems: Capsular Contracture

    MAUDE report 16902367 ↗

Other Prosthesis, breast, noninflatable, internal, silicone gel-filled devices

All Prosthesis, breast, noninflatable, internal, silicone gel-filled devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page