Insignia 236-1-24018Recalls & reported problems

Alphatec Spine, Inc. · 4.0mm Variable Angle, Self-Drilling Screw, Single Lead 18mm · Class 2 · Implant

All models of Insignia (34)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00190376329796), received between Sep 22, 2022 and Apr 13, 2026 — classified as 3 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Fracture” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 2 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture4
  • Detachment of Device or Device Component1
  • Device Dislodged or Dislocated1
  • Material Protrusion/Extrusion1

Patient problems

  • Failure of Implant5
  • Post Operative Wound Infection1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 13, 2026Fracture

    A PATIENT UNDERWENT AN ANTERIOR CERVICAL DISCECTOMY AND FUSION PROCEDURE ON (B)(6), 2025. IT WAS REPORTED THAT A SCREW BROKE 1 YEAR POSTOPERATIVELY. REVISION SURGERY IS PLANNED FOR (B)(6), 2026 TO REMOVE THE BROKEN SCREW.

    Patient problems: Failure of Implant

    MAUDE report 24865369 ↗
  • MalfunctionMar 31, 2026Fracture

    A PATIENT UNDERWENT A 3-LEVEL ANTERIOR CERVICAL AND DISCECTOMY FUSION PROCEDURE ON (B)(6) 2025. ABOUT 6 MONTHS POSTOPERATIVELY, RADIOGRAPHIC IMAGES REVEALED THAT TWO SUPERIOR SCREWS HAD FRACTURED, AND 1 INFERIOR SCREW HAD BEGUN TO BACKOUT OF THE PLATE. THERE ARE NO PLANS FOR REVISION SURGERY. THIS IS REPORT 2 OF 3.

    Patient problems: Failure of Implant

    MAUDE report 24746098 ↗
  • MalfunctionMar 31, 2026Fracture

    A PATIENT UNDERWENT A 3-LEVEL ANTERIOR CERVICAL AND DISCECTOMY FUSION PROCEDURE ON (B)(6) 2025. ABOUT 6 MONTHS POSTOPERATIVELY, RADIOGRAPHIC IMAGES REVEALED THAT TWO SUPERIOR SCREWS HAD FRACTURED, AND 1 INFERIOR SCREW HAD BEGUN TO BACKOUT OF THE PLATE. THERE ARE NO PLANS FOR REVISION SURGERY. THIS IS REPORT 1 OF 3.

    Patient problems: Failure of Implant

    MAUDE report 24746054 ↗
  • InjuryJun 19, 2023Detachment of Device or Device Component; Detachment of Device or Device Component

    ON (B)(6) 2023, A PATIENT UNDERWENT A 2-LEVEL ANTERIOR CERVICAL DISCECTOMY AND FUSION AT C5-C7. ON (B)(6) 2023, DUE TO AN INFECTION AT THE SURGICAL SITE, THE PATIENT UNDERWENT AN INCISION AND DRAINAGE (I&D). DURING THE I&D PROCEDURE, THE SURGEON FOUND THE LEFT C7 SCREW BACKING OUT AND THE OVERLYING PORTION OF THE BLOCKER BENT, BUT STILL COVERING THE SCREW. THE BENT PORTION OF THE BLOCKER WAS BUMPED DURING SUCTION, CAUSING IT TO BREAK FREE FROM THE PLATE/BLOCKER ASSEMBLY. THE BROKEN PORTION WAS REMOVED FROM THE PATIENT. THE REMAINING PORTION OF THE BLOCKER, COVERING THE RIGHT-SIDE SCREW, ALONG WITH THE CENTRAL ATTACHMENT POINT OF THE BLOCKER TO THE PLATE REMAINED INTACT. THE LEFT C7 SCREW WAS REMOVED, THE WASH OUT WAS COMPLETED, AND THE SURGEON CLOSED THE WOUND.

    Patient problems: Post Operative Wound Infection

    MAUDE report 17159687 ↗
  • InjurySep 24, 2022Fracture; Fracture

    AT THE 6-WEEK POSTOPERATIVE VISIT, A RADIOGRAPH REVEALED A SCREW FRACTURE. REVISION SURGERY WAS PERFORMED TO REMOVE AND REPLACE THE HARDWARE.

    Patient problems: Failure of Implant

    MAUDE report 15478529 ↗
  • MalfunctionSep 22, 2022Device Dislodged or Dislocated; Material Protrusion/Extrusion; Device Dislodged or Dislocated; Material Protrusion/Extrusion

    AT THE 3-MONTH POSTOPERATIVE VISIT, A RADIOGRAPH REVEALED A SCREW BACKOUT AT C6.

    Patient problems: Failure of Implant

    MAUDE report 15464996 ↗

Other Appliance, fixation, spinal intervertebral body devices

All Appliance, fixation, spinal intervertebral body devices →