SafeOp AIX11901Recalls & reported problems
Alphatec Spine, Inc. · SafeOp 1.5 Head Unit · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 00190376330723), received between May 21, 2022 and Feb 20, 2026 — classified as 3 injuries, 6 malfunctions.
The most frequently reported specific device problem is “Device Provides Uninformative Message” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Device Provides Uninformative Message3
- Adverse Event Without Identified Device or Use Problem2
- Incorrect, Inadequate or Imprecise Result or Readings2
- Device Sensing Problem1
- Low Readings1
- Use of Device Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions7
- Muscle Weakness/Atrophy1
- Twitching1
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 20, 2026Device Provides Uninformative Message
DURING A SPINAL PROCEDURE USING INTRAOPERATIVE NEUROMONITORING, IT WAS REPORTED THAT THE SYSTEM DISPLAYED AN ERROR MESSAGE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24406032 ↗MalfunctionJan 13, 2026Incorrect, Inadequate or Imprecise Result or Readings; Device Provides Uninformative Message
DURING A SPINAL PROCEDURE USING INTRAOPERATIVE NEUROMONITORING, IT WAS REPORTED THAT THE SYSTEM DISPLAYED AN ERROR MESSAGE AND EXPERIENCED A FAILED TRIGGERED EMG. THE SCREW TESTING COULD NOT BE COMPLETED, BUT THERE WAS NO PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24059635 ↗InjuryJan 6, 2026Incorrect, Inadequate or Imprecise Result or Readings
DURING A SPINAL PROCEDURE USING INTRAOPERATIVE NEUROMONITORING, MULTIPLE ELECTRODE CHECKS WOULD NOT PASS THE IMPEDANCE TEST. THE HARNESS AND INDIVIDUAL ELECTRODES WERE REPLACED WITH NO RESOLUTION. THE PATIENT WAS ALREADY UNDER ANESTHESIA. THE SURGEON ELECTED TO ABORT THE CASE PRIOR TO INCISION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23978131 ↗InjuryDec 15, 2025Device Provides Uninformative Message; Device Provides Uninformative Message
THE SYSTEM DISPLAYED AN ERROR MESSAGE AFTER PATIENT POSITIONING AND SKIN MARKING, BUT PRIOR TO SKIN INCISION. BASELINE RECORDINGS HAD ALREADY BEEN SUCCESSFULLY OBTAINED PRIOR TO THE ALERT. TROUBLESHOOTING WAS ATTEMPTED BUT DID NOT RESOLVE THE ISSUE. THE SURGEON ELECTED TO CANCEL THE PROCEDURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23810981 ↗MalfunctionJan 13, 2024Device Sensing Problem; Device Sensing Problem
IT WAS REPORTED DURING A CASE, THE STANDARD NEEDLE SET UP WAS COMPLETED. WHEN THE LEADS WERE PLUGGED INTO THE UNIT, THE GROUND ELECTRODE WAS NOT REGISTERING IN THE ELECTRODE TEST. THE NEEDLE AND HARNESS WERE REPLACED WITH NO CHANGE. ANOTHER UNIT WAS USED TO COMPLETE THE CASE. THIS RESULTED IN A DELAY IN SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18509535 ↗MalfunctionMar 18, 2023Use of Device Problem; Use of Device Problem
IT WAS REPORTED DURING SURGERY, THE UNIT GAVE A "CHECK PROBE" ERROR MESSAGE SEVERAL TIMES. MULTIPLE ATTEMPTS WERE MADE TO RESOLVE THE ERROR MESSAGE. THIS RESULTED IN A DELAY IN SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16569447 ↗MalfunctionNov 23, 2022Low Readings; Low Readings
IT WAS REPORTED DURING A CASE INVOLVING A SAFEOP UNIT LOW TEMG THRESHOLDS OCCURRED ACROSS MULTIPLE SURGICAL LEVELS. THE SURGEON ABORTED THE CASE. IT IS UNKNOWN IF THE LOW VALUES WERE ARTIFACT. THE SALES REP IS CONFIDENT THE BOVIE PAD WASN'T NEAR LEADS AND THAT STIM RETURN AS WELL AS GROUND WERE IN CORRECT LOCATIONS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15852591 ↗MalfunctionNov 16, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED A PATIENT UNDERWENT A SINGLE LEVEL L4-L5 LIF PROCEDURE WHICH INVOLVED A SAFEOP UNIT. AFTER THE EMG ELECTRODES WERE CONNECTED THERE WAS SPONTANEOUS STIMULATING TO THE PATIENT WITHOUT ANY TRIGGERED EMG BEING ACTIVATED. THE HEADBOX TO THE UNIT WAS TURNED ON AND OFF MULTIPLE TIMES. THERE WAS A RHYTHMIC TWITCH IN THE PATIENT'S FOOT WHEN THE MACHINE WAS ON, BUT WITHOUT THE INPUT OF ANY TRIGGERED EMG OR SSEP STIMULUS. THIS SAME TWITCH WAS NOT PRESENT WHEN THE HEADBOX POWER WAS TURNED OFF. THE SURGEON ABORTED THE CASE DUE TO THIS INCIDENT.
Patient problems: Twitching
MAUDE report 15810419 ↗InjuryMay 21, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ON (B)(6) 2022, A PATIENT HAD A POSTOPERATIVE DEFICIT AFTER UNDERGOING A SPINAL PROCEDURE WHERE A SAFEOP UNIT WAS USED. IT WAS REPORTED THE PATIENT HAD QUADRICEPS WEAKNESS ON THE OPERATIVE SIDE. THERE WAS NO ALLEGATION OF PRODUCT MALFUNCTION.
Patient problems: Muscle Weakness/Atrophy
MAUDE report 14465333 ↗
Other STIMULATOR, NERVE devices
- NIM Vital NIM4CM01Medtronic Xomed, Inc. · STIMULATOR, NERVE2 recalls260 reports
- NIM TriVantage® 8229707Medtronic Xomed, Inc. · STIMULATOR, NERVE2 recalls176 reports
- NIM® 8229306Medtronic Xomed, Inc. · STIMULATOR, NERVE1 recall1 death167 reports
- NIM Vital™ NIM4CPB1Medtronic Xomed, Inc. · STIMULATOR, NERVE3 recalls45 reports
- NIM Trivantage® 8229707Medtronic Xomed, Inc. · STIMULATOR, NERVE1 recall142 reports
- NIM® 8229307Medtronic Xomed, Inc. · STIMULATOR, NERVE1 recall138 reports
- NIM TriVantage® 8229706Medtronic Xomed, Inc. · STIMULATOR, NERVE2 recalls78 reports
- NIM-Response® 8253002Medtronic Xomed, Inc. · STIMULATOR, NERVE171 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page