Skip to content

Insignia 436-0354Recalls & reported problems

Alphatec Spine, Inc. · Insignia 3-Level ACP, 54mm · Class 2 · Implant

All models of Insignia (34)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00190376491226), received between Jun 7, 2024 and Jul 7, 2025 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 2 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Dislodged or Dislocated3

Patient problems

  • Failure of Implant1
  • No Clinical Signs, Symptoms or Conditions1
  • Pain1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 7, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated

    APPROXIMATELY 10 MONTHS POSTOPERATIVELY, RADIOGRAPHIC IMAGING REVEALED ONE OF THE INFERIOR SCREWS BACKING OUT OF THE PLATE AT THE C6 LEVEL. REVISION SURGERY WAS PERFORMED TO REMOVE BOTH OF THE INFERIOR SCREWS FROM THE PLATE.

    Patient problems: Failure of Implant

    MAUDE report 22420395 ↗
  • MalfunctionJun 18, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    A PATIENT UNDERWENT A 3-LEVEL ANTERIOR CERVICAL DISCECTOMY AND FUSION SPINAL PROCEDURE ON AN UNKNOWN DATE. IT WAS REPORTED THAT A SCREW BACKED OUT POSTOPERATIVELY. THERE IS NO REPORT OF PATIENT SYMPTOMS OR PLANS OF REVISION SURGERY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19563793 ↗
  • InjuryJun 7, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    A PATIENT UNDERWENT A 3-LEVEL ANTERIOR CERVICAL DISCECTOMY AND FUSION SPINAL PROCEDURE ON AN UNKNOWN DATE. POSTOPERATIVELY, THE PATIENT REPORTED PAIN. RADIOGRAPH IMAGES REVEALED ONE OF THE INFERIOR SCREWS IS BACKING OUT. REVISION SURGERY WAS PERFORMED TO REMOVE THE IMPLANTED HARDWARE.

    Patient problems: Pain

    MAUDE report 19482671 ↗

Other Appliance, fixation, spinal intervertebral body devices

All Appliance, fixation, spinal intervertebral body devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page