Skip to content

DJO SURGICAL 940-01-48DRecalls & reported problems

Encore Medical, L.P. · EMPOWR Acetabular System, Cup, Hemispherical, Solid Back, 48 · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00190446311393), received between Mar 18, 2026 and Jun 3, 2026 — classified as 2 injuries.

The most frequently reported specific device problem is “Loosening of Implant Not Related to Bone-Ingrowth” (1 report).

5 other recalls cover devices cleared under the same FDA submission (K190057); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Loosening of Implant Not Related to Bone-Ingrowth1

Patient problems

  • Joint Laxity2
  • Metal Related Pathology1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 3, 2026Loosening of Implant Not Related to Bone-Ingrowth

    REVISION SURGERY - DUE TO FLUID CONSISTENCY WITH ALTR W POSITIVE DEBRIS METAL ION COBALT LEVEL ELEVATED CONVERSION REVISION SURGERY. LOOSE CUP UPON EVALUATION. DR. (B)(6) REPORTS: 1. REVISION SURGERY OF A FEMALE PATIENT WHO RECEIVED AN EMPOWR 48MM CUP WITH A DUAL MOBILITY BEARING, 3-4 YEARS POST-OP. 2. PRESENCE OF METALLOSIS AND DAMAGED BONE IN THE PELVIS THAT ALMOST CREATED A DISCONTINUITY. 3. LINER WAS INSTALLED PERFECTLY (PROPERLY ALIGNED AND NOT CANTED). 4. PREOP FOR COBALT WAS VERY HIGH AND MRI SHOWED ALTR. PREOP ASPIRATION HAD WHITE FLUID WITH MINIMAL CELLS COUNTED MANUALLY.

    Patient problems: Joint Laxity; Metal Related Pathology

    MAUDE report 25369527 ↗
  • InjuryMar 18, 2026Adverse Event Without Identified Device or Use Problem

    LOOSE CUP.

    Patient problems: Joint Laxity

    MAUDE report 24635008 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K190057. One submission often covers many models, so check the product and lot details in each record.

  • Z-1234-2026 · Jan 5, 2026 · Open, Classified
    EMPOWR Acetabular System: Liner, 10 degree Hooded, HXe+, 36H, REF: 942-01-36H; Liner, 10 degree Hooded, HXe+, 36J, REF: 942-01-36J; Liner, 10 degree Hooded, HXe+, 40G, REF: 942-01
  • Z-0103-2024 · Aug 22, 2023 · Open, Classified
    EMPOWR Acetabular System, Liner, 10 Hooded, HXe+, 40H, REF: 942-01-40H
  • Z-0125-2023 · Aug 12, 2022 · Open, Classified
    EMPOWR Acetabular System, Liner, 10 deg Hooded, HXe+ 40H, REF: 942-01-40H. Orthopedic implant component.
  • Z-0135-2021 · Sep 9, 2020 · Open, Classified
    EMPOWR Acetabular System *** EMPOWR Acetabular Cup, Cluster Hole, 54G *** Size 54G 54 mm Dia./Cluster Hole Alpha Code G Liner P2 Porous Coated REF 940-02-54G - Product Usage: are
  • Z-1929-2020 · Oct 22, 2019 · Open, Classified
    EMPOWR Acetabular System, Non-Sterile, Model Numbers 803-15-023 803-15-026 803-15-027 803-15-028 803-15-029 803-15-030 Product Usage: The EMPOWR Acetabular Impactor Balls is int

Other PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED devices

All PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page