- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00190446311614), received between Oct 7, 2020 and Jul 1, 2025 — classified as 4 injuries.
5 other recalls cover devices cleared under the same FDA submission (K190057); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem4
Patient problems
- Joint Dislocation2
- Joint Laxity2
- Fall1
- Unspecified Infection1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryJul 1, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
REVISION SURGERY - DUE TO INSTABILITY AND DISLOCATION.
Patient problems: Joint Dislocation; Joint Laxity
MAUDE report 22378974 ↗InjuryFeb 21, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
InjuryJan 24, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
InjuryOct 7, 2020Adverse Event Without Identified Device or Use Problem
REVISION SURGERY - PATIENT SUFFERED A FALL AND DAMAGE TO THE CLOSING WOUND, IT BECAME INFECTED SO THE SURGEON DECIDED TO PULL ALL IMPLANTS AND LET INFECTION HEAL BEFORE REVISING AT A LATER DATE.
Patient problems: Fall; Unspecified Infection
MAUDE report 10641879 ↗
FDA clearance and classification
Cleared through 510(k) K190057 on Jun 7, 2019 (decision: Substantially Equivalent). Submitted by Encore Medical L.P. as “DJO Acetabular System”. The FDA review took 147 days. FDA record ↗
The FDA regulates product code OQG (hip prosthesis, semi-constrained, cemented, metal/polymer, + additive, porous, uncemented) under 21 CFR 888.3358 as a Class II device. 21 CFR 888.3358 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K190057. One submission often covers many models, so check the product and lot details in each record.
- Z-1234-2026 · Jan 5, 2026 · Open, ClassifiedEMPOWR Acetabular System: Liner, 10 degree Hooded, HXe+, 36H, REF: 942-01-36H; Liner, 10 degree Hooded, HXe+, 36J, REF: 942-01-36J; Liner, 10 degree Hooded, HXe+, 40G, REF: 942-01
- Z-0103-2024 · Aug 22, 2023 · Open, ClassifiedEMPOWR Acetabular System, Liner, 10 Hooded, HXe+, 40H, REF: 942-01-40H
- Z-0125-2023 · Aug 12, 2022 · Open, ClassifiedEMPOWR Acetabular System, Liner, 10 deg Hooded, HXe+ 40H, REF: 942-01-40H. Orthopedic implant component.
- Z-0135-2021 · Sep 9, 2020 · Open, ClassifiedEMPOWR Acetabular System *** EMPOWR Acetabular Cup, Cluster Hole, 54G *** Size 54G 54 mm Dia./Cluster Hole Alpha Code G Liner P2 Porous Coated REF 940-02-54G - Product Usage: are
- Z-1929-2020 · Oct 22, 2019 · Open, ClassifiedEMPOWR Acetabular System, Non-Sterile, Model Numbers 803-15-023 803-15-026 803-15-027 803-15-028 803-15-029 803-15-030 Product Usage: The EMPOWR Acetabular Impactor Balls is int
Common questions about the DJO SURGICAL 940-02-62I
Has the DJO SURGICAL 940-02-62I been recalled?
No FDA recall record in our data names this exact device identifier (DI 00190446311614), based on the FDA recall file dated Nov 27, 2026. However, 5 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.
What problems have been reported with the DJO SURGICAL 940-02-62I?
The FDA's MAUDE database lists 4 adverse event reports for this device, received between Oct 7, 2020 and Jul 1, 2025. In those reports, the most common patient problems are “Joint Dislocation” (2), “Joint Laxity” (2) and “Fall” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the DJO SURGICAL 940-02-62I?
None of the reports are classified as deaths, 4 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the DJO SURGICAL 940-02-62I FDA approved?
It was cleared through 510(k) K190057 on Jun 7, 2019. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the DJO SURGICAL 940-02-62I MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the DJO SURGICAL 940-02-62I, and is it still sold?
The FDA's device database lists Encore Medical, L.P. as the company responsible for it (brand DJO SURGICAL, model 940-02-62I). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Hip Prosthesis, semi-constrained, cemented, metal/polymer, + additive, porous, uncemented devices
- DJO SURGICAL 942-01-40HEncore Medical, L.P. · Hip Prosthesis, semi-constrained, cemented, metal/polymer, + additive, porous, uncemented2 recalls23 reports
- Vivacit-E® 110031012Zimmer, Inc. · Hip Prosthesis, semi-constrained, cemented, metal/polymer, + additive, porous, uncemented1 recall32 reports
- G7® Dual Mobility Acetabular System 110024462Biomet Orthopedics, LLC · Hip Prosthesis, semi-constrained, cemented, metal/polymer, + additive, porous, uncemented1 recall22 reports
- DJO SURGICAL 942-01-36HEncore Medical, L.P. · Hip Prosthesis, semi-constrained, cemented, metal/polymer, + additive, porous, uncemented1 recall5 reports
- DJO SURGICAL 942-01-32CEncore Medical, L.P. · Hip Prosthesis, semi-constrained, cemented, metal/polymer, + additive, porous, uncemented1 recall0 reports
- DJO SURGICAL 942-01-36JEncore Medical, L.P. · Hip Prosthesis, semi-constrained, cemented, metal/polymer, + additive, porous, uncemented1 recall0 reports
- TAPERLOC COMPLETE XR 123 MICRO FEMORAL 51-145150Biomet Orthopedics, LLC · Hip Prosthesis, semi-constrained, cemented, metal/polymer, + additive, porous, uncemented42 reports
- TAPERLOC COMPLETE MICRO PRIMARY FEMORAL 51-106160Biomet Orthopedics, LLC · Hip Prosthesis, semi-constrained, cemented, metal/polymer, + additive, porous, uncemented35 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page