Skip to content

Triumph® 205-202Recalls & reported problems

Ortho Organizers, Inc. · Triumph® Weingart Pliers · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00190707081621), received between Oct 16, 2020 and Oct 16, 2020 — classified as 1 injury.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Break1

Patient problems

  • Abrasion1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 16, 2020Break; Break

    THE TIP OF THE TRIUMPH WEINGART PLIER BROKE OFF WHILE BEING USED IN THE MOUTH DURING ORTHODONTIC TREATMENT RESULTING IN INJURY TO THE INNER CHEEK. THE BROKEN PIECE WAS RETRIEVED WITHOUT FURTHER INCIDENT. PATIENT WAS PRESCRIBED PAINKILLERS AND ANTIBIOTICS TO TREAT THE INNER CHEEK INJURY.

    Patient problems: Abrasion

    MAUDE report 10693788 ↗

FDA clearance and classification

The FDA regulates product code JEX (plier, orthodontic) under 21 CFR 872.4565 as a Class I device. 21 CFR 872.4565 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Triumph® 205-202

Has the Triumph® 205-202 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00190707081621), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Triumph® 205-202?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Oct 16, 2020. That report lists device problem “Break” (1); patient problem “Abrasion” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Triumph® 205-202?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Triumph® 205-202 FDA approved?

Devices of this type (product code JEX) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Ortho Organizers, Inc.

Who makes the Triumph® 205-202, and is it still sold?

The FDA's device database lists Ortho Organizers, Inc. as the company responsible for it (brand Triumph®, model 205-202). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other PLIER, ORTHODONTIC devices

All PLIER, ORTHODONTIC devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page