ENDOSKELETON® TO 3114-2614Recalls & reported problems
Medtronic Sofamor Danek, Inc. · Interbody Fusion Device 4 Degree PLIF 14mm · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00191375004769), received between Feb 24, 2017 and Feb 24, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Device Dislodged or Dislocated1
Patient problems
- No Code Available1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 24, 2017Device Dislodged or Dislocated
AN L4/5 TLIF PROCEDURE OCCURRED ON (B)(6) 2016 IMPLANTING AN ENDOSKELETON® TO 0 DEG LORDOTIC, IMPLANT, 26X14MM, PLIF. APPROXIMATELY TWO WEEK LATER, THE PATIENT DESCRIBES HEARING A "POP" IN HER BACK. PATIENT HAD L5 VERTEBRAL FRACTURE. PATIENT WAS SCHEDULED FOR REVISION SURGERY, CAGE WAS REMOVED, PATIENT WAS RE-INSTRUMENTED WITH PEDICLE SCREWS. THERE WAS NO ADVERSE EFFECTS OR INJURY TO THE PATIENT AS A RESULT. THE EXPLANTED DEVICE WAS KEPT AT (B)(6). PATIENT IS A FEMALE, (B)(6), NON-SMOKER. PATIENT DID NOT FALL. PATIENT DOES NOT HAVE PRIOR FUSIONS AT LEVELS THAT WERE BEING TREATED. PATIENT WAS GIVEN POST-OPERATIVE INSTRUCTIONS.
Patient problems: No Code Available
MAUDE report 6358584 ↗
Other Intervertebral fusion device with bone graft, lumbar devices
- T-PAL 03.812.003Synthes GmbH · Intervertebral fusion device with bone graft, lumbar152 reports
- T-PAL 03.812.004Synthes GmbH · Intervertebral fusion device with bone graft, lumbar120 reports
- Catalyft PL Expandable Interbody System 6068073Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall66 reports
- Catalyft PL Expandable Interbody System 6069076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall51 reports
- Catalyft PL Expandable Interbody System 6068076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall46 reports
- EIT TLIF Inserter TFT30101EIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Lumbar88 reports
- T-PAL 03.812.001Synthes GmbH · Intervertebral fusion device with bone graft, lumbar76 reports
- Catalyft PL Expandable Interbody System 6069096Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page