ENDOSKELETON® TC nanoLOCK® Surface Technology 5166-1407-NRecalls & reported problems
Medtronic Sofamor Danek, Inc. · Interbody Fusion Device 6 Degree Medium 7mm · Class 2 · Implant
All models of ENDOSKELETON TC nanoLOCK Surface Technology (6)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00191375013075), received between Oct 22, 2025 and Oct 22, 2025 — classified as 1 injury.
The most frequently reported specific device problem is “Loosening of Implant Not Related to Bone-Ingrowth” (1 report).
4 other recalls cover devices cleared under the same FDA submission (K141953, K183557, K192018); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Loosening of Implant Not Related to Bone-Ingrowth1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 22, 2025Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PRODUCT USED IN ANTERIOR CERVI CAL DISCECTOMY AND FUSION (ACDF) SPINAL PROCEDURE FOR HERNIATED DISC AT LEVELS HWK 4/5/6. IT WAS REPORTED THAT THE CAGES FILLED WITH GLASSBONE BIOACTIVE BONE SUBSTITUTE/INJECTABLE PUTTY, THE CAGES BECAME LOOSE AND SLIPPED, AND NO SOLID FUSION WAS ACHIEVED. ADDITIONAL SURGERY WAS PERFORMED, DURING WHICH THE CAGES WERE REMOVED AND REPLACED. THERE WERE NO FURTHER COMPLICATIONS OR SYMPTOMS AS A RESULT OF THE EVENT. ADDITIONAL INFORMATION WAS RECEIVED VIA MANUFACTURER REPRESENTATIVE THAT THE PATIENT HAD TO UNDERGO FURTHER SURGERY DUE TO SECONDARY BLEEDING AND THE RESULTING PARAPLEGIA. ACCORDING TO THE SURGEON, THIS WAS LOCATED IN THE C5/C6 SEGMENT. HE DETERMINED THAT THERE WAS NO CONNECTION TO THE VENTRALLY DISLOCATED CAGE IN THE C4/C5 SEGMENT. THE PATIENT UNFORTUNATELY DIED ON (B)(6) 2025, FROM MULTIPLE ORGAN FAILURE AND SEPSIS. HOWEVER, ACCORDING TO THE SURGEON, THIS WAS NOT RELATED WITH REPORTED PRODUCTS (CAGES).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23354888 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K141953, K183557, K192018. One submission often covers many models, so check the product and lot details in each record.
- Z-0086-2022 · Sep 2, 2021 · TerminatedEndoskeleton" TCS Interbody System with Titan nanoLOCK" Surface Technology, NanoLock, 6 Deg, Interbody, Medium, 10mm
- Z-0085-2022 · Sep 2, 2021 · TerminatedEndoskeleton" TAS Interbody System with Titan nanoLOCK" Surface Technology, Nanolock 12 Dg Interbody, Large, 12mm
- Z-1439-2021 · Mar 17, 2021 · TerminatedEndoskeleton TC Interbody System with Titan nanoLOCK Surface Technology, 6 Degree, Small, 8 mm, Product Number 5146-1208-N - Product Usage: indicated to be used with supplemental f
- Z-1440-2021 · Mar 17, 2021 · TerminatedEndoskeleton TC Interbody System with Titan nanoLOCK Surface Technology, 6 Degree, Large, 8 mm, Product Number 5146-1608-N - Product Usage: indicated to be used with supplemental f
Other Intervertebral fusion device with bone graft, cervical devices
- ROI-C MC1005TLDR Spine Usa, Inc. · Intervertebral Fusion Device With Bone Graft, Cervical54 reports
- EIT CIF cage CUI8070SEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall4 reports
- EIT CIF cage CUI8060LEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall1 report
- CONSTRUX - MINI Ti 37-7212SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-8015SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-7206SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-8007SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI PTC 37-4211SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page