POLARMAP™ M004CRBS7210Recalls & reported problems
Boston Scientific Corporation · Circular Mapping Catheter · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00191506039769), received between Dec 26, 2023 and Jul 29, 2025 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Contamination” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Contamination1
- Material Integrity Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 29, 2025Material Integrity Problem; Material Integrity Problem
IT WAS REPORTED THAT THE CATHETER SHAFT WAS DAMAGED OR DEFECTIVE. DURING PREPARATION PRIOR TO A PROCEDURE FOR TREATING ATRIAL FIBRILLATION (AFIB), A POLARMAP CATHETER WAS SELECTED FOR USE. IT WAS OBSERVED THAT THE CATHETER BECAME STUCK IN THE TUOHY VALVE AND COULD NOT BE RETRACTED. UPON RELEASE, SLIGHT DAMAGE OR SHEARING OF THE CATHETER SHAFT NEAR THE ELECTRODES WAS NOTED. AN ATTEMPT WAS MADE TO LOOSEN THE TUOHY VALVE TO FREE THE CATHETER WITHOUT CAUSING FURTHER DAMAGE, BUT IT WAS UNSUCCESSFUL. THE PROCEDURE WAS COMPLETED USING A DIFFERENT DEVICE OF THE SAME MODEL. NO PATIENT COMPLICATIONS OCCURRED. THE DEVICE WAS DISPOSED OF BY THE FACILITY AND WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22645789 ↗MalfunctionDec 26, 2023Contamination; Contamination
IT WAS REPORTED THAT DURING THE PREPARATION OF A CRYOABLATION PROCEDURE TO TREAT AN ATRIAL FIBRILLATION (AF), A POLARMAP CATHETER WAS SELECTED FOR USE. DEVICE BECAME UNSTERILE AND IT WAS DECIDED TO REPLACE IT RATHER THAN PROCEED. PROCEDURE WAS ABLE TO BE COMPLETED SUCCESSFULLY WITHOUT ANY PATIENT COMPLICATIONS. DEVICE IS NOT EXPECTED TO BE RETURNED AS IT WAS DISPOSED. IT WAS FURTHER REPORTED THAT THE CATHETER WAS LOOPED ON THE PATIENT FIELD. IT BECAME UNSTERILE WHEN UNWRAPPED AND IT HIT THE SCRUB NURSE IN THE HEAD.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18393473 ↗
Other CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices
- Advisor™ HD Grid, Sensor Enabled™ D-AVHD-DF16St. Jude Medical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths358 reports
- IntellaMap Orion™ M004RC64S0Boston Scientific Corporation · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths356 reports
- ACHIEVE™ 990063-020Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING7 deaths129 reports
- Inquiry™ IBI-81104Irvine Biomedical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 recall2 deaths64 reports
- DECANAV R7F282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING4 deaths108 reports
- LASSO NAV D134301Biosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING2 deaths82 reports
- DECANAV R7D282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 death75 reports
- ACHIEVE ADVANCE™ 2ACH20Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING3 deaths69 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.