Trapper™ H74939739130Recalls & reported problems

Boston Scientific Corporation · Exchange Device · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00191506048938), received between Mar 20, 2025 and Sep 10, 2026 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Material Rupture” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 2 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Rupture6
  • Adverse Event Without Identified Device or Use Problem1
  • Difficult to Advance1
  • Fluid/Blood Leak1
  • Inflation Problem1
  • Material Deformation1
  • Mechanical Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 10, 2026Fluid/Blood Leak; Inflation Problem; Material Rupture

    It was reported that a balloon rupture occurred.A Trapper Exchange Device was selected for use. At the course of the procedure, the device was advanced into the guide catheter to facilitate a microcatheter removal. However, it was noted that the balloon appeared to have a small hole that prevented adequate inflation. As the pressure in the inflation device was increased, the pressure gauge kept falling back down as the balloon lost pressure. Upon removing the device from the guide, the physician inspected it closely and saw a pinhole in the balloon which caused it to leak contrast during inflation. The procedure was completed with another of the same device. There were no patient complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50716782 ↗
  • MalfunctionSep 18, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT BALLOON RUPTURE OCCURRED. THE TARGET LESION WAS LOCATED IN THE HEART. A TRAPPER EXCHANGE DEVICE WAS SELECTED FOR USE. DURING THE PROCEDURE, BALLOON WAS INFLATED ONCE AND RUPTURED RIGHT AT 6 ATMOSPHERES. THE BALLOON WAS REMOVED FROM THE PATIENT BODY, AND THE PROCEDURE WAS COMPLETED WITH AN ALTERNATE DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23091554 ↗
  • MalfunctionSep 17, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT A BALLOON RUPTURE OCCURRED. DURING THE PROCEDURE, THE TRAPPER BALLOON WAS INFLATED TO 16 ATM BEFORE RUPTURING. THE PROCEDURE WAS COMPLETED WITH ANOTHER TRAPPER BALLOON. THERE WERE NO PATIENT COMPLICATIONS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23071309 ↗
  • MalfunctionAug 20, 2025Material Rupture; Adverse Event Without Identified Device or Use Problem; Material Rupture; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A BALLOON RUPTURE OCCURRED. A TRAPPER EXCHANGE DEVICE WAS SELECTED FOR USE. DURING THE PROCEDURE, THE BALLOON BURST. THE DEVICE WAS REMOVED FROM THE PATIENT BODY, AND THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. NO COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22856688 ↗
  • MalfunctionApr 1, 2025Material Rupture; Material Rupture

    IT WAS NOTED THAT A BALLOON RUPTURE OCCURRED. THE PATIENT PRESENTED WITH CORONARY ARTERY DISEASE AND UNDERWENT PERCUTANEOUS CORONARY INTERVENTION. THE TARGET LESION WAS LOCATED IN THE CORONARY ARTERY. A TRAPPER EXCHANGE BALLOON WAS SELECTED FOR USE. DURING PREPARATION, IT WAS NOTED THAT THE BALLOON COULD NOT HOLD PRESSURE AS THE AIR BUBBLES WOULD NOT STOP COMING FROM THE CATHETER INTO THE SYRINGE DUE TO PINHOLE IN THE BALLOON. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF SAME DEVICE. NO PATIENT COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21740630 ↗
  • MalfunctionMar 20, 2025Mechanical Problem; Material Rupture; Difficult to Advance; Material Deformation; Mechanical Problem; Material Rupture; Difficult to Advance; Material Deformation

    IT WAS REPORTED THAT THE TRAPPER GOT A PINHOLE IN THE BALLOON. A TRAPPER EXCHANGE DEVICE WAS SELECTED FOR CHRONIC TOTAL OCCLUSION. DURING THE PROCEDURE, THE TRAPPER BENT GOING INTO THE COLLAR OF THE GUIDE EXTENSION. IT WOULD NOT ADVANCE PAST THE COLLAR OF THE GUIDEZILLA. THEN NOMINAL PRESSURE WAS APPLIED. THE TRAPPER POSSIBLY GOT A PINHOLE IN THE BALLOON WHILE TRYING TO GET PAST THE GUIDEZILLA AND CAUSING THE BALLOON TO NO LONGER HOLD THE WIRE. THE PROCEDURE WAS COMPLETED WITH A DIFFERENT DEVICE. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21658373 ↗

Other Catheter, percutaneous devices

All Catheter, percutaneous devices →