Skip to content

Vicks VIH200WMRecalls & reported problems

Kaz USA, Inc. · VICKS STEAM INHALER - EXTRA SCENT PADS WALMART · Class 1

All models of Vicks (12)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00328785005820), received between May 2, 2024 and May 2, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information1
  • Unexpected Therapeutic Results1

Patient problems

  • Blister1
  • Erythema1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 2, 2024Unexpected Therapeutic Results; Insufficient Device Problem Information; Unexpected Therapeutic Results; Insufficient Device Problem Information

    THE REPORTER CALLED REGARDING VICKS SINUS NASAL INHALER HUMIDIFIER. THE REPORTER MENTIONED THAT HER NIECE WAS USING THE DEVICE ON HER BABY AS THE BABY WAS SUFFERING FROM CHEST CONGESTION. THE HUMIDIFIER CAUSED THE BABY'S CHEST BURN WITH REDNESS AND BLISTERS AND THE MOTHER GOT SCALD ON HER CHEST. THIS INFORMATION WAS RELAYED TO KAZ USA, INC. THROUGH MEDWATCH FORM #MW5153521; THE CONSUMER HAD NEVER PREVIOUSLY CONTACTED OUR COMPANY. WE REACHED OUT TO THE CONSUMER'S RELATIVE WHO WAS UNSURE OF THE EXTENT OF ANY INJURIES, AND UNSURE EXACTLY HOW THE PRODUCT WAS BEING USED WHEN THE ALLEGED INCIDENT OCCURRED. THE PATIENTS INVOLVED WERE THE INITIAL REPORTER'S NIECE, AND THE NIECE'S INFANT CHILD. KAZ USA, INC HAS REQUESTED THAT THE PRODUCT BE RETURNED TO OUR COMPANY FOR TESTING.

    Patient problems: Blister; Erythema

    MAUDE report 19229928 ↗

Other Humidifier, Non-Direct Patient Interface (Home-Use) devices

All Humidifier, Non-Direct Patient Interface (Home-Use) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page