CORGRIP* Nasogastric/Nasointestinal Feeding Tube Retention System 120008151Recalls & reported problems
Avanos Medical, Inc. · Corpgrip NG/NI tube retention system · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00350770005997), received between Jun 9, 2026 and Jun 9, 2026 — classified as 2 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Pressure Sore/Ulcer2
- Device Embedded In Tissue or Plaque1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJun 9, 2026Adverse Event Without Identified Device or Use Problem
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED DIFFERENT INCIDENTS, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING DIFFERENT PATIENTS. THIS IS THE SECOND OF TWO REPORTS. REFER TO 3011270181-2026-00084 FOR THE FIRST REPORT. THE CUSTOMER REPORTED A PRESSURE INJURY ASSOCIATED WITH USE OF A TUBE RETENTION SYSTEM. ADDITIONAL INFORMATION RECEIVED ON MAY 20, 2026, REPORTED THAT THE RETENTION TETHER BECAME EMBEDDED IN THE PATIENT'S SKIN, WITH SKIN REPORTEDLY GROWING OVER THE TETHER. THE CONDITION WAS IDENTIFIED DURING REMOVAL OF THE FEEDING TUBE AND RETENTION SYSTEM ON (B)(6) 2026. THE DEVICE HAD REPORTEDLY BEEN PLACED AT ANOTHER FACILITY ON (B)(6) 2026. NO PATIENT DEMOGRAPHIC INFORMATION, MEDICAL INTERVENTION DETAILS, OR PATIENT OUTCOME INFORMATION WERE PROVIDED.
Patient problems: Device Embedded In Tissue or Plaque; Pressure Sore/Ulcer
MAUDE report 25448993 ↗InjuryJun 9, 2026Adverse Event Without Identified Device or Use Problem
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED DIFFERENT INCIDENTS, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING DIFFERENT PATIENTS. THIS IS THE FIRST OF TWO REPORTS. REFER TO 3011270181-2026-00085 FOR THE SECOND REPORT. THE CUSTOMER REPORTED A PRESSURE INJURY ASSOCIATED WITH USE OF A TUBE RETENTION SYSTEM. ADDITIONAL INFORMATION RECEIVED ON MAY 20, 2026, REPORTED THAT THE PRESSURE INJURY EXTENDED TO BONE AND WAS DESCRIBED AS SMALL IN AREA BUT DEEP. NO PATIENT DEMOGRAPHIC INFORMATION, MEDICAL INTERVENTION DETAILS, OR PATIENT OUTCOME INFORMATION WERE PROVIDED DESPITE FOLLOW-UP REQUESTS.
Patient problems: Pressure Sore/Ulcer
MAUDE report 25448992 ↗
Other Tubes, gastrointestinal (and accessories) devices
- Bard® DigniShield® Stool Management System SMS002C. R. Bard, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)2 deaths525 reports
- CORTRAK* 2 ENTERAL ACCESS SYSTEM 20-0950Avanos Medical, Inc. · Tubes, gastrointestinal (and accessories)1 recall22 deaths134 reports
- Bard Tri-Funnel Replacement Gastrostomy Tube 000720Bard Access Systems, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)1 death170 reports
- EndoVive Safety PEG Kit M00566470Boston Scientific Corporation · TUBES, GASTROINTESTINAL (AND ACCESSORIES)1 recall1 death111 reports
- Kangaroo 8884711253Cardinal Health, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)152 reports
- NutraGlide Nasal Feeding Tube ENFT-06090-IApplied Medical Technology, Inc. · Tubes, Gastrointestinal (And Accessories)2 recalls0 reports
- NutraGlide Nasal Feeding Tube ENFT-05090-IApplied Medical Technology, Inc. · Tubes, Gastrointestinal (And Accessories)2 recalls0 reports
- Kangaroo 8884711253ECardinal Health, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)100 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.