AVANOS 44089Recalls & reported problems
Avanos Medical, Inc. · MIC-KEY* Gastric-Jejunal Feeding Tube Kit Extension Sets · Class 2 · Implant
Data updated Nov 27, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00350770440897), received between May 19, 2020 and May 7, 2021 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (3 reports).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Recalls naming this device
- May 31, 2024Class IIOpen, Classified
The IFU was missing some risk information requested by another country to be contained in the IFU pertaining to potential complications.
Z-2422-2024 · Root cause: Error in labeling · Recall details · FDA record ↗
Most reported problems
Device problems
- Fluid/Blood Leak3
- Material Split, Cut or Torn3
- Material Perforation1
Patient problems
- No Consequences Or Impact To Patient2
- No Known Impact Or Consequence To Patient1
- Vomiting1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 7, 2021Fluid/Blood Leak; Material Perforation; Fluid/Blood Leak; Material Perforation
IT WAS REPORTED THAT THE PATIENT RETURNED TO THE HOSPITAL TWO AND A HALF WEEKS AFTER REPLACEMENT OF THE TUBE DUE TO VOMITING WHICH OCCURRED WHEN THE JEJUNAL CONNECTOR WAS BEING USED FOR FEEDING. THE BALLOON WAS DEFLATED AND THE FEEDING TUBE WAS INSPECTED. A PERFORATION OF THE TUBING WAS FOUND JUST BELOW THE BALLOON, IN THE AREA BETWEEN THE STOMACH AND THE DUODENUM, RESULTING IN A POSSIBLE LEAK INTO THE STOMACH OF FEED INTENDED FOR THE JEJUNUM. A NEW FEEDING TUBE WAS PLACED. PER ADDITIONAL INFORMATION RECEIVED 19 APR 2021, AFTER THE CHANGING OUT OF THE FEEDING TUBE, "EVERYTHING IS OK."
Patient problems: Vomiting
MAUDE report 11790810 ↗MalfunctionAug 24, 2020Fluid/Blood Leak; Material Split, Cut or Torn; Fluid/Blood Leak; Material Split, Cut or Torn
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS. THIS IS THE SECOND OF TWO REPORTS. REFER TO 9611594-2020-00163 FOR THE FIRST REPORT. IT WAS REPORTED THAT THE DEVICE WAS PLACED (B)(6) 2020 AND REMOVED (B)(6) 2020 DUE TO "ASPIRATING FROM G [GASTROSTOMY TUBE], RUPTURED." NO PATIENT INJURY WAS REPORTED. ADDITIONAL INFORMATION RECEIVED FROM THE AVANOS REPRESENTATIVE ON (B)(6) 2020 INDICATED THERE IS A CLEAR SPLIT IN THE JUNCTION BETWEEN THE JEJUNAL AND GASTRIC LINES OF THE FEEDING TUBE. ADDITIONAL INFORMATION HAS BEEN REQUESTED BUT NOT YET RECEIVED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10445880 ↗MalfunctionAug 24, 2020Fluid/Blood Leak; Material Split, Cut or Torn; Fluid/Blood Leak; Material Split, Cut or Torn
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS. THIS IS THE FIRST OF TWO REPORTS. REFER TO 9611594-2020-00164 FOR THE SECOND REPORT. IT WAS REPORTED THAT THE FEEDING TUBE WAS PLACED (B)(6) 2020 AND REMOVED (B)(6) 2020 DUE TO "GJ [GASTROJEJUNAL TUBE ASPIRATING MILK BACK FROM GASTRIC PORT WHEN JEJ [JEJUNAL] FED. REMOVED AND TESTED AND WHEN FLUSHED THROUGH JEJ PORT, FEED COMES OUT OF GASTRIC TUBE. REMOVED AND FLUSHED WATER THROUGH JEJ PORT AND CLEARLY ABLE TO SEE IT COME OUT OF GASTRIC HOLE." TUBE REMOVED AND REPLACED WITH LOW PROFILE BUTTON. NO PATIENT INJURY WAS REPORTED. THE AVANOS REPRESENTATIVE STATED "I ATTACHED EXTENSION SETS TO BOTH OUTLETS, I CLAMPED THE JEJUNAL END NEAR THE STRIPE AWAY FROM THE GASTRIC OUTLET. I THEN PLACED IN WATER AND WAS ABLE TO ASPIRATE WATER VIA THE JEJUNAL PORT. THERE IS A LEAK BETWEEN THE GASTRIC AND JEJUNAL TUBES." ADDITIONAL INFORMATION HAS BEEN REQUESTED BUT NOT YET RECEIVED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10445826 ↗MalfunctionMay 19, 2020Material Split, Cut or Torn; Material Split, Cut or Torn
IT WAS REPORTED THAT THE GASTROJEJUNAL (GJ) TUBE WAS PLACED (B)(6) 2020 AND REMOVED (B)(6) 2020. THE CUSTOMER STATED, "GJ TUBE ASPIRATING MILK BACK FROM GASTRIC POT [PORT] WHEN JEJ [JEJUNAL] FED. MUM [MOTHER] REPORTS BEING ABLE TO ASPIRATE FEED BACK FROM GASTRIC PORT. SEEN IN PEG CLINIC AND PLAN TO REMOVE. TUBE REMOVED AND TESTED AND WHEN FLUSHED THROUGH JEJ PORT, FEED COMES OUT GASTRIC HOLE." THE CUSTOMER ALSO STATED "YOU CANNOT SEE ANY SPLIT IN THE TUBE BUT WHEN THE TUBE IS FLUSHED, YOU CAN CLEARLY SEE WATER COME OUT OF THE GASTRIC HOLE WHEN FLUSHED THROUGH THE JEJ PORT." NO PATIENT INJURY WAS REPORTED. THE CUSTOMER PROVIDED A PHOTO OF THE DEVICE ON (B)(6) 2020.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10072320 ↗
FDA clearance and classification
The FDA regulates product code KNT (tubes, gastrointestinal (and accessories)) under 21 CFR 876.5980 as a Class II device. 21 CFR 876.5980 ↗
Devices of this type normally need 510(k) clearance before sale.
Common questions about the AVANOS 44089
Has the AVANOS 44089 been recalled?
Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-2422-2024 (Class II), began on May 31, 2024: The IFU was missing some risk information requested by another country to be contained in the IFU pertaining to potential complications. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.
What problems have been reported with the AVANOS 44089?
The FDA's MAUDE database lists 4 adverse event reports for this device, received between May 19, 2020 and May 7, 2021. In those reports, the most common specific device problems are “Fluid/Blood Leak” (3), “Material Split, Cut or Torn” (3) and “Material Perforation” (1); the most common patient problem is “Vomiting” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the AVANOS 44089?
None of the reports are classified as deaths, 0 as injuries and 4 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the AVANOS 44089 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.
Who makes the AVANOS 44089, and is it still sold?
The FDA's device database lists Avanos Medical, Inc. as the company responsible for it (brand AVANOS, model 44089). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Tubes, gastrointestinal (and accessories) devices
- Bard® DigniShield® Stool Management System SMS002C. R. Bard, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)2 deaths522 reports
- CORTRAK* 2 ENTERAL ACCESS SYSTEM 20-0950Avanos Medical, Inc. · Tubes, gastrointestinal (and accessories)1 recall22 deaths134 reports
- Bard Tri-Funnel Replacement Gastrostomy Tube 000720Bard Access Systems, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)1 death170 reports
- EndoVive Safety PEG Kit M00566470Boston Scientific Corporation · TUBES, GASTROINTESTINAL (AND ACCESSORIES)1 recall1 death111 reports
- Kangaroo 8884711253Cardinal Health, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)152 reports
- Kangaroo 8884711253ECardinal Health, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)101 reports
- NutraGlide Nasal Feeding Tube ENFT-05090-IApplied Medical Technology, Inc. · Tubes, Gastrointestinal (And Accessories)2 recalls0 reports
- NutraGlide Nasal Feeding Tube ENFT-06090-IApplied Medical Technology, Inc. · Tubes, Gastrointestinal (And Accessories)2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026 · each recall links to the FDA recall notice
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page