AVANOS 44573Recalls & reported problems

Avanos Medical, Inc. · MIC* Gastric-Jejunal Feeding Tube Kit with ENFit® Connector - Endoscopic/Radiologic Placement · Class 2 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00350770445731), received between Oct 8, 2020 and Feb 27, 2026 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak1
  • Leak/Splash1
  • Material Split, Cut or Torn1

Patient problems

  • Insufficient Information1
  • No Clinical Signs, Symptoms or Conditions1
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 27, 2026Fluid/Blood Leak

    IT WAS REPORTED THERE WAS AN "OBSTRUCTION AND BREAKAGE OF THE JEJUNAL EXTENSION NEAR THE BALLOON DURING INFUSION OF THE MIXTURE INTO THE GASTRIC LUMEN.¿ ADDITIONAL INFORMATION CLARIFICATION RECEIVED 09-FEB-2026 NOTED THE USER "REPORTS OBSTRUCTION OF THE JEJUNAL EXTENSION, CAUSING RUPTURE OF THE JEJUNAL EXTENSION ITSELF AND THEREFORE LEAKAGE OF FLUID INTO THE GASTRIC LUMEN." NO ADDITIONAL INFORMATION WAS PROVIDED. THERE WAS NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24472228 ↗
  • MalfunctionDec 14, 2023Leak/Splash; Leak/Splash

    IT WAS REPORTED, THE JEJUNAL LUMEN WAS LEAKING INTERNALLY (APPROXIMATELY 3CM FROM THE BALLOON). IT WAS CONFIRMED VIA TUBOGRAM. PATIENT REQUIRED MULTIPLE SHORT INTERNAL TUBE EXCHANGES DUE TO SMALL ISSUE. TUBE EXCHANGED FOR A NEW ONE. NO INJURY REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 18327695 ↗
  • MalfunctionOct 8, 2020Material Split, Cut or Torn; Material Split, Cut or Torn

    IT WAS REPORTED THAT THERE IS A, "HOLE IN THE TUBE JUST UNDER FEED PORTS. ALSO 1 MONTH REPORTS OF MEDS [MEDICATION] GIVEN VIA JEJ, JEJUNAL PORT, APPEARING IN GASTRIC TUBE, AND GASTRIC DRAINAGE BAG." NO PATIENT INJURY WAS REPORTED. ADDITIONAL INFORMATION RECEIVED 21-SEP-2020 INDICATED THE FEEDING TUBE WAS REPLACED IN INTERVENTIONAL RADIOLOGY. THERE WAS NO HARM TO THE PATIENT. ADDITIONAL INFORMATION RECEIVED 24-SEP-2020 IN THE FORM OF AN EVALUATION REPORT FROM THE DISTRIBUTOR INDICATED THE PRODUCT WAS IN USE FOR APPROXIMATELY 5 MONTHS. THE BALLOON WAS INFLATED USING 10ML OF COOLED, BOILED WATER. ACCORDING TO THE DISTRIBUTOR, NO OBVIOUS SIGNS OF MOLDING DEFORMITY OR MANUFACTURING MATERIAL WEAKNESS WERE IDENTIFIED. NO SIGN OF A LEAK FROM THE JEJUNAL LUMEN INTO THE GASTRIC LUMEN WAS IDENTIFIED. A TEAR WAS IDENTIFIED AT THE CONNECTION BETWEEN THE TUBING SECTION, AND THE FEED PORT SECTION OF THE DEVICE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10648286 ↗

Other Tubes, gastrointestinal (and accessories) devices

All Tubes, gastrointestinal (and accessories) devices →