CORPAK ENTERIC FEEDING TUBE W/GUIDE TIP 50-4602Recalls & reported problems
Avanos Medical, Inc. · CORFLO* Nasointestinal Endoscopically Placed Feeding Tube with ENFit® Connector · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00350770461946), received between Jul 17, 2023 and Mar 17, 2026 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
- Detachment of Device or Device Component1
- Malposition of Device1
- Material Split, Cut or Torn1
- Unintended Movement1
Patient problems
- Foreign Body In Patient3
- Insufficient Information1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 17, 2026Detachment of Device or Device Component
IT WAS REPORTED "A SMALL BOWEL FEEDING TUBE WAS PLACED AND WHEN THE PATIENT ARRIVED HOME, THEY WERE UNABLE TO FLUSH THE TUBE AND ULTIMATELY FOUND A SMALL WIRE STICKING OUT OF ONE OF THE PORTS. THEY PULLED IT OUT AND BROUGHT IT BACK WITH THEM. PATIENT WAS SEDATED AGAIN, THE OLD TUBE WAS REMOVED, AND A NEW TUBE WAS PLACED. THE WIRE WITH THE INITIAL TUBE WAS FOUND TO BE THE SHEATH OF THE AVANOS GUIDEWIRE. THIS SHEATH IS MEANT TO REMAIN ON THE GUIDE WIRE ADDING ADDITIONAL RIGIDITY, KEEPING THE GUIDEWIRE INTACT, AND PREVENTING BENDING OF THE WIRE." THERE WAS NO REPORTED INJURY.
Patient problems: Foreign Body In Patient
MAUDE report 24621320 ↗MalfunctionNov 7, 2024Break; Break
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING THE SAME PATIENT. THIS IS THE SECOND OF TWO REPORTS. REFER TO 9611594-2024-00236 FOR THE FIRST REPORT. IT WAS REPORTED, ¿TUBE HAS BLOWN OUT AT A WEAK POINT IN DEVICE.¿
Patient problems: Insufficient Information
MAUDE report 20629205 ↗MalfunctionNov 7, 2024Break; Malposition of Device; Break; Malposition of Device
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING THE SAME PATIENT. THIS IS THE FIRST OF TWO REPORTS. REFER TO 9611594-2024-00237 FOR THE SECOND REPORT. IT WAS REPORTED, EVIDENCE OF DEVICE IN WRONG POSITION. UPON INVESTIGATION UNDER GENERAL ANESTHESIA, TUBE FOUND TO BE IN TWO SEPARATE SECTIONS. BROKEN SECTION REMOVED (B)(6) 2024.
Patient problems: Foreign Body In Patient
MAUDE report 20629201 ↗MalfunctionJul 17, 2023Unintended Movement; Material Split, Cut or Torn; Unintended Movement; Material Split, Cut or Torn
IT WAS REPORTED, THE NASOJEJUNAL TUBE RUPTURED AFTER TWO MONTHS. THE PATIENT CONTACTED THE DEPARTMENT ON (B)(6) 2023 AND AN X-RAY CONFIRMED THE RUPTURE. THE LOWER END OF THE TUBE WAS IN THE STOMACH INSTEAD OF THE INTESTINES. ENDOSCOPIC INSERTION OF ANOTHER TUBE WAS PERFORMED WITH RADIOLOGICAL CONTROL OF CORRECT POSITIONING WITH OPACIFICATION. THE PATIENT'S STATUS WAS REPORTED TO BE ¿CORRECT". NO INJURY REPORTED.
Patient problems: Foreign Body In Patient
MAUDE report 17333284 ↗
Other Tubes, gastrointestinal (and accessories) devices
- Bard® DigniShield® Stool Management System SMS002C. R. Bard, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)2 deaths525 reports
- CORTRAK* 2 ENTERAL ACCESS SYSTEM 20-0950Avanos Medical, Inc. · Tubes, gastrointestinal (and accessories)1 recall22 deaths134 reports
- Bard Tri-Funnel Replacement Gastrostomy Tube 000720Bard Access Systems, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)1 death170 reports
- EndoVive Safety PEG Kit M00566470Boston Scientific Corporation · TUBES, GASTROINTESTINAL (AND ACCESSORIES)1 recall1 death111 reports
- Kangaroo 8884711253Cardinal Health, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)152 reports
- NutraGlide Nasal Feeding Tube ENFT-06090-IApplied Medical Technology, Inc. · Tubes, Gastrointestinal (And Accessories)2 recalls0 reports
- NutraGlide Nasal Feeding Tube ENFT-05090-IApplied Medical Technology, Inc. · Tubes, Gastrointestinal (And Accessories)2 recalls0 reports
- Kangaroo 8884711253ECardinal Health, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)100 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page