ACRYSOF® Monoflex® MA50BM (REF MA50BM.220)Recalls & reported problems

Alcon Laboratories, Inc. · AcrySof(R) SOFT ACRYLIC MULTIPIECE STERILEPCL (IOL/PC), 13.0mm LENGTH, 6.5mm BICONVEXOPTIC, 10-DEGREE Monoflex(TM*) HAPTICS. *REG. U.S. PAT. & TM OFF. · Class 3 · Implant

All models of ACRYSOF Monoflex (94)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00380650698575), received between May 26, 2022 and Dec 4, 2025 — classified as 5 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Scratched Material2
  • Crack1
  • Defective Device1
  • Device Difficult to Setup or Prepare1
  • Failure to Deliver1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Insufficient Information2

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 4, 2025Break; Failure to Deliver; Break; Failure to Deliver

    A PHARMACIST REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE SURGEON MADE SEVERAL INJECTION ATTEMPTS. HOWEVER, THE IMPLANT BECAME STUCK INSIDE THE CARTRIDGE, AND ONE OF THE HAPTICS BROKE. THE PROCEDURE WAS COMPLETED WITH SAME MODEL AND DIOPTER COMPANY LENS. ADDITIONAL INFORMATION HAS BEEN REQUESTED, RECEIVED AND STATED THE ISSUE OCCURRED DURING THE PROGRESSION OF IMPLANT IN THE CARTRIDGE. LENS/INJECTOR TOUCHED THE PATIENT'S EYE.

    Patient problems: Insufficient Information

    MAUDE report 23716509 ↗
  • MalfunctionNov 3, 2025Scratched Material; Scratched Material

    A HEALTH CARE PROFESSIONAL REPORTED THAT DURING CATARACT SURGERY WITH IOL IMPLANTATION SURGEON NOTICED THAT THE INTRAOCULAR LENS WAS SCRATCHED. ADDITIONAL INFORMATION HAS BEEN RECEIVED STATED THAT THE IOL HAS BEEN REMOVED AND REPLACED DURING INITIAL PROCEDURE. SURGERY WAS COMPLETED ON THE SAME DAY WITHOUT ANY HARM TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23449952 ↗
  • MalfunctionMay 8, 2024Break; Device Difficult to Setup or Prepare; Scratched Material; Break; Device Difficult to Setup or Prepare; Scratched Material

    A FACILITY REPRESENTATIVE REPORTED DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE INTRAOCULAR LENS WAS DAMAGED UPON INSERTION, AND LENS WAS REMOVED DURING INITIAL PROCEDURE. THE PROCEDURE WAS COMPLETED WITH ANOTHER LENS. ADDITIONAL INFORMATION HAS BEEN RECEIVED AND STATED THAT INTRAOCULAR LENS WAS DAMAGED UPON INSERTION. THE HAPTIC GOT CRACKED OFF AND THE LENS WAS ACCIDENTALLY SCRATCHED. THE DAMAGE WAS NOTICED UPON INSERTION AND THE LENS HAD TO BE REMOVED WITH A LENS CUTTER. THE EVENT WAS CAUSED BY FAILURE TO PROPERLY LOAD LENS IN CARTRIDGE. NO PATIENT HARM WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19268316 ↗
  • MalfunctionAug 3, 2022Defective Device; Defective Device

    A NON-HEALTH PROFESSIONAL REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE LENS WAS NOTED DEFECTIVE. ADDITIONAL INFORMATION HAS BEEN REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15157145 ↗
  • MalfunctionMay 26, 2022Crack; Crack

    A HEALTHCARE PROFESSIONAL REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE IOL HAD PRE-EXISTING DEFECTS AT THE HAPTIC-OPTIC JUNCTION. NOTICED A GRAY-COLORED CRACK WITHIN THE OPTIC CLOSE TO THE HAPTIC. THEY APPEARED TO BE MANUFACTURING DEFECTS AND DID NOT APPEAR TO BE DEFECTS RELATED TO IOL LOADING OR INSERTION. THE IOL WAS REPLACED WITH ANOTHER LENS DURING THE INITIAL PROCEDURE WITH NO PATIENT HARM. THE IOL WAS CUT INTO 3 PIECES DURING EXPLANATION, THE GREEN ARROW POINTS TO THE VERTICAL GRAY-COLORED CRACK WITHIN THE OPTIC CLOSE TO THE HAPTIC-OPTIC JUNCTION ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: Insufficient Information