ACRYSOF® SA60WF (REF SA60WF.255)Recalls & reported problems

Alcon Laboratories, Inc. · AcrySof(R) ASPHERIC IOL, SINGLE-PIECE ACRYLICFOLDABLE POSTERIOR CHAMBER LENS,UV-ABSORBING, 13.0mm LENGTH, 6.0mm ANTERIORASYMMETRIC BICONVEX OPTIC, PLANAR HAPTICS. · Class 3 · Implant

All models of ACRYSOF (353)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00380652332774), received between Nov 11, 2021 and Jul 7, 2025 — classified as 1 injury, 6 malfunctions.

The most frequently reported specific device problem is “Defective Device” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Defective Device2
  • Scratched Material2
  • Appropriate Device Problem Term/Code Not Available1
  • Break1
  • Crack1
  • Failure to Eject1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Insufficient Information2
  • Eye Injury1
  • Inflammation1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 7, 2025Break; Break

    A NURSE REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE HAPTIC WAS BROKEN BEFORE IMPLANTATION. THE PROCEDURE WAS COMPLETED ON THE SAME DAY USING ANOTHER UNSPECIFIED LENS. THERE WAS NO IMPACT ON PATIENT. ADDITIONAL INFORMATION HAS BEEN REQUESTED. THERE ARE TWO MEDICAL DEVICE REPORTS ASSOCIATED WITH THIS REPORT. THIS IS 1 OF 2.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22412959 ↗
  • InjuryAug 6, 2024Scratched Material; Scratched Material

    A HEALTH CARE PROFESSIONAL REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, NURSE LOAD IOL INTO CARTRIDGE AND INJECTOR BUT DID NOT OBSERVED LENS BEFORE. THEN PASS TO SURGEON FOR IMPLANTATION. THIS WAS COMMON PRACTICE OF THE SITE AND NO PRIOR EVENT LIKE THIS. SURGEON NOTICED VACUOLE-LIKE AND SCRATCH MARK ON THE LENS AFTER LOADING INTO PATIENT¿S EYES AND HAD TO CUT THE LENS TO EXTRACT IT OUT IN THE SAME OPERATION. BUT HAD TO WIDEN THE CUT MARK TO REMOVE THE PIECES OF LENS OUT. A NEW IOL REPLACED IN THE SAME OPERATION BUT TOOK LONGER TIME TO FINISH AND AS A RESULT WOUND WAS WIDEN THAN USUAL HAD TO STITCH THE WOUND CLOSE. PATIENT HAD INFLAMMATION AND ANTIBIOTICS WAS GIVEN AFTER THE SURGERY AND DOES NOT REQUIRE ADDITIONAL HOSPITAL STAY. THERE ARE THREE MEDICAL DEVICE REPORTS ASSOCIATED WITH THIS REPORT. THIS IS 1 OF 3.

    Patient problems: Eye Injury; Inflammation

    MAUDE report 19919179 ↗
  • MalfunctionFeb 9, 2024Defective Device; Defective Device

    AN OTHER HEALTH CARE PROFESSIONAL REPORTED THE LENS AS DEFECTIVE. ADDITIONAL INFORMATION WAS REQUESTED, BUT NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: Insufficient Information

    MAUDE report 18674979 ↗
  • MalfunctionSep 27, 2023Scratched Material; Scratched Material

    A HEALTHCARE PROFESSIONAL REPORTED THAT, DURING INTRAOCULAR LENS IMPLANTATION SURGERY, THE BODY OF THE LENS HAD SCRATCH APPROXIMATELY 1-2MM FROM THE EDGE. THE LENS WAS IMPLANTED INTO THE PATIENT'S EYE AND THE SURGEON DID NOT REMOVE THE IMPLANTED LENS.

    Patient problems: Insufficient Information

    MAUDE report 17823729 ↗
  • MalfunctionJan 2, 2023Crack; Crack

    A PHYSICIAN REPORTED THAT DURING A CATARACT EXTRACTION WITH INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, A LINE WAS ONLY DETECTED UNDER THE MICROSCOPE AFTER THE IMPLANTATION OF IOL. THE IOL WAS NOT EXPLANTED. THERE WAS NO PATIENT HARM. ADDITIONAL INFORMATION HAS BEEN REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16082312 ↗
  • MalfunctionApr 25, 2022Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    A FACILITY REPRESENTATIVE REPORTED THAT DURING A CATARACT EXTRACTION WITH INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE LENS DID NOT LOAD PROPERLY. ADDITIONAL INFORMATION RECEIVED ON 31MAR2022, STATED THAT THERE IS A PATIENT CONTACT AND A POSSIBLE INJECTOR ISSUE. THE REPLACEMENT IOL WAS USED AND THERE WAS NO PATIENT HARM, THE ISSUE WAS RESOLVED, AND PATIENT WAS NO HOSPITALIZED. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14191634 ↗
  • MalfunctionNov 11, 2021Defective Device; Failure to Eject; Defective Device; Failure to Eject

    A NURSE REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE LENS DID NOT LOAD PROPERLY. ADDITIONAL INFORMATION WAS PROVIDED STATED THAT LENS WAS STUCK IN THE CARTRIDGE AND POSSIBLE INJECTOR ISSUE, IT WAS UNSURE IF IT WAS THE LENS, CARTRIDGE OR THE INJECTOR WAS BEING USED THERE WAS NO PATIENT HARM AND THE SURGEON PROGNOSIS WAS GOOD. THE PATIENT WAS NOT HOSPITALIZED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12796628 ↗

Other intraocular lens devices

All intraocular lens devices →