Clareon™ CCA0T0 (UDI 00380652397452)Recalls & reported problems

Alcon Laboratories, Inc. · STERILE UV Absorbing Hydrophobic Acrylic Foldable Aspheric Posterior Chamber Intraocular Lens with the AutonoMe™ Automated Pre-loaded Delivery System · Class 3 · Implant

All models of Clareon (1142)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00380652397452), received between May 4, 2022 and Feb 16, 2026 — classified as 1 injury, 5 malfunctions.

The most frequently reported specific device problem is “Device Difficult to Setup or Prepare” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Device Difficult to Setup or Prepare1
  • Failure to Deliver1
  • Failure to Fold1
  • Failure to Unfold or Unwrap1
  • Inaccurate Delivery1
  • Unintended Ejection1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Insufficient Information2
  • Blurred Vision1
  • Visual Impairment1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 16, 2026Device Difficult to Setup or Prepare; Failure to Deliver

    A NONHEALTH CARE PROFESSIONAL REPORTED THAT DURING THE INTRAOCULAR LENS (IOL) IMPLANTATION SURGERY, THE TRAILING HAPTIC WAS STUCK TO THE PLUNGER AND IT WOULD NOT ADVANCE FAR ENOUGH TO BE RELEASED INTO THE EYE. ADDITIONAL INFORMATION HAS BEEN REQUESTED BUT IS NOT AVAILABLE AT THE TIME OF THIS REPORT

    Patient problems: Insufficient Information

    MAUDE report 24344836 ↗
  • MalfunctionNov 10, 2025Inaccurate Delivery; Inaccurate Delivery

    A NON-HEALTHCARE PROFESSIONAL REPORTED THAT DURING INTRAOCULAR LENS (IOL) IMPLANTATION, THE DOCTOR ATTEMPTED TO ADVANCE THE IOL, AND THE IMPLANT WAS PUSHED OUT THROUGH THE TIP OF THE INSERTER. THERE WAS PATIENT CONTACT REPORTED IN RIGHT EYE. THE PROCEDURE WAS COMPLETED ON SAME DAY WITH UNSPECIFIED REPLACEMENT LENS AND THERE WAS NO IMPACT TO THE PATIENT ADDITIONAL INFORMATION HAS BEEN REQUESTED HOWEVER NO FURTHER INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23510103 ↗
  • MalfunctionJul 1, 2025Failure to Fold; Failure to Fold

    A FACILITY REPRESENTATIVE REPORTED WITH DESCRIPTION OF LENS LOADING ERROR. ADDITIONAL INFORMATION HAS BEEN REQUESTED.

    Patient problems: Insufficient Information

    MAUDE report 22370797 ↗
  • MalfunctionMay 8, 2025Failure to Unfold or Unwrap; Failure to Unfold or Unwrap

    A FACILITY REPRESENTATIVE REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, TRAILING HAPTIC WAS STUCK TO POSTERIOR SIDE OF OPTIC NOTICED UPON INSERTION IN THE EYE. HAPTIC WAS RELEASED FROM THE OPTIC. LENS REMAINS IMPLANTED. THERE WAS NO PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21986327 ↗
  • MalfunctionApr 21, 2023Unintended Ejection; Unintended Ejection

    A SURGEON REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE LENS ADVANCED TOO EARLY AND BECAME STUCK IN THE INCISION, THE SURGEON REMOVED THE LENS FROM THE WOUND AND USED A NEW LENS. THERE WAS NO PATIENT INJURY. THE INCISION WAS NOT ENLARGED AND NO SUTURE WAS NECESSARY. ADDITIONAL INFORMATION HAS BEEN REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16784055 ↗
  • InjuryMay 4, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A NURSE REPORTED FOLLOWING AN INTRAOCULAR LENS IMPLANT PROCEDURE, THE PATIENT EXPERIENCED UNEXPECTED OUTCOMES, WANTS DISTANT VISION AND LENS POWER ISSUE. THE LENS WAS EXCHANGED IN A SECONDARY PROCEDURE. ADDITIONAL INFORMATION HAS BEEN REQUESTED.

    Patient problems: Blurred Vision; Visual Impairment

    MAUDE report 14275999 ↗

Other intraocular lens devices

All intraocular lens devices →