Skip to content

Clareon CNA0T4 (REF CNA0T4.060)Recalls & reported problems

Alcon Laboratories, Inc. · CLAREON TORIC AUTONOME · Class 3 · Implant

All models of Clareon (1142)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00380652399074), received between Apr 29, 2025 and Jul 28, 2025 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Device Damaged by Another Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 2 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Damaged by Another Device1
  • Failure to Advance1
  • Failure to Prime1
  • Inaccurate Delivery1
  • Material Discolored1

Patient problems

  • Insufficient Information2
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 28, 2025Failure to Prime; Failure to Advance; Device Damaged by Another Device; Failure to Prime; Failure to Advance; Device Damaged by Another Device

    A HEALTH CARE PROFESSIONAL REPORTED THAT, DURING THE INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE THE PLUNGER MOVED OVER TOP OF THE OPTIC AND LENS DIDN'T FOLD OR DELIVER. THE IOL WAS DAMAGED AND DISCARDED. THERE WAS NO PATIENT CONTACT. NO FURTHER INFORMATION EXPECTED AS REPORTER UNWILLING TO PROVIDE ADDITIONAL INFORMATION.

    Patient problems: Insufficient Information

    MAUDE report 22631759 ↗
  • MalfunctionJul 23, 2025Inaccurate Delivery; Inaccurate Delivery

    A HEALTHCARE PROFESSIONAL REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANTATION PROCEDURE, THE LENS WAS INITIALLY DELIVERED UPSIDE DOWN. IT WAS SUBSEQUENTLY FLIPPED INTO POSITION AND REMAINS IN SITU. ADDITIONAL INFORMATION WAS RECEIVED INDICATING THAT THE INTRAOCULAR LENS (IOL), WHICH WAS INITIALLY IMPLANTED UPSIDE DOWN, WAS REPOSITIONED BY FLIPPING IT IN SITU AND ROTATING IT INTO THE CORRECT POSITION.

    Patient problems: Insufficient Information

    MAUDE report 22577044 ↗
  • MalfunctionApr 29, 2025Material Discolored; Material Discolored

    A PHYSICIAN REPORTED THAT AFTER IMPLANTATION OF LENS DURING THE INTRAOCULAR LENS (IOL) IMPLANTATION PROCEDURE, THE IOL LOOKED BLUE IMMEDIATELY. THE SURGERY WAS COMPLETED WITHOUT PRODUCT REPLACEMENT. IT WAS UNKNOWN WHETHER THESE FINDINGS DISAPPEARED OR CONTINUED. THE LENS REMAINED IMPLANTED. THERE HAVE BEEN NO REPORTED HEALTH PROBLEMS OR HARM TO THE PATIENT. ADDITIONAL INFORMATION WAS REQUESTED, BUT NO FURTHER INFORMATION IS AVAILABLE. THERE ARE 224 MEDICAL DEVICE REPORTS ASSOCIATED WITH THIS EVENT. THIS IS 134 OF 224.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21927214 ↗

Other Intraocular Lens devices

All Intraocular Lens devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page