Clareon CNW0T6 (UDI 00380652411004)Recalls & reported problems
Alcon Laboratories, Inc. · CLAREON BLF TORIC · Class 3 · Implant
All models of Clareon (1142)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00380652411004), received between Jul 17, 2023 and Jul 17, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Malposition of Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Malposition of Device1
Patient problems
- Visual Disturbances1
- Visual Impairment1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJul 17, 2023Malposition of Device; Malposition of Device
A PHYSICIAN REPORTED THAT DURING THE CATARACT SURGERY WITH INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, LENS WAS INSERTED WITH THE WRONG AXIS DURING INSERTION AND SURGERY WAS PERFORMED AGAIN AFTER THE SURGERY. AFTER THE FIRST SURGERY, THE PATIENT REPORTED DIFFICULTY IN SEEING, AND WHEN THE DOCTOR CHECKED, IT WAS FOUND THAT THE PATIENT'S ASTIGMATISM HAD INCREASED. WHEN CHECKED, DOCTOR FOUND THAT THE AXIS AT THE TIME OF INSERTION WAS MISALIGNED, AND DOCTOR CORRECTED IT TO THE CORRECT AXIS. AFTER THAT, THE PATIENT DID NOT COMPLAIN.
Patient problems: Visual Disturbances; Visual Impairment
MAUDE report 17332341 ↗
Other intraocular lens devices
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens146 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens145 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens144 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens139 reports
- TECNIS SIMPLICITY DIB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens1 recall81 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens129 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens127 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens126 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page