Skip to content

Clareon CNW0T7 (UDI 00380652411622)Recalls & reported problems

Alcon Laboratories, Inc. · CLAREON BLF TORIC · Class 3 · Implant

All models of Clareon (1142)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00380652411622), received between Aug 24, 2023 and Jan 13, 2026 — classified as 2 injuries.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2

Patient problems

  • Blurred Vision2
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Visual Disturbances1
  • Visual Impairment1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 13, 2026Adverse Event Without Identified Device or Use Problem

    A NURSE REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, PATIENT HAD BLURRED VISION NOT GETTING BETTER, SHADOWS AROUND LETTERS, SIGNS AND DIFFERENT OBJECTS. PATIENT COULD NOT SEE LEAVES ON TREES AND IOL OVER-CORRECTED ASTIGMATISM. PLANNED TO REPLACE WITH AN UNKNOWN ADVANCED TECHNOLOGY INTRAOCULAR LENS (ATIOL).

    Patient problems: Blurred Vision; Visual Disturbances; Visual Impairment

    MAUDE report 24053451 ↗
  • InjuryAug 24, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A PHYSICIAN REPORTED THAT AFTER IMPLANTATION OF INTRAOCULAR LENS, THE PATIENT'S VISUAL ACUITY WAS MEASURED IN JUNE AFTER SURGERY, THE VISUAL ACUITY WAS NOT GOOD. NON-INFLAMMATORY CELLS WERE ADHERED ON FRONT OF IOL OVER ALMOST THE ENTIRE CIRCUMFERENCE OF THE IOL. YAG CAPSULOTOMY WAS PERFORMED. ADDITIONAL INFORMATION WAS REQUESTED AND RECEIVED STATING THE PATIENT HAD RESIDUAL ASTIGMATISM THOUGH TORIC IOL WAS IMPLANTED. THE PHYSICIAN CONSIDERED THAT THIS SYMPTOM WAS FROM LENS EPITHELIAL CELLS AFTER RECEIVING THE INFORMATION THAT THIS CASES WERE SIMILAR TO LENS EPITHELIAL CELL ON-GROWTH (LECOG). IN ADDITIONAL, THE PHYSICIAN SUSPECTED THAT THIS SYMPTOM MIGHT BE RELATED WITH TRABECULECTOMY 30 YEARS AGO (INFLAMMATORY RESPONSE). THERE ARE TWO MEDICAL DEVICE REPORTS ASSOCIATED WITH THIS PATIENT. THIS REPORT IS ASSOCIATED WITH THE RIGHT EYE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Blurred Vision

    MAUDE report 17610538 ↗

Other intraocular lens devices

All intraocular lens devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page