Clareon CCWTT0 (UDI 00380652413527)Recalls & reported problems
Alcon Laboratories, Inc. · Clareon PanOptix UVA · Class 3 · Implant
All models of Clareon (1142)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 8
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 00380652413527), received between Oct 4, 2023 and Sep 8, 2025 — classified as 8 injuries.
The most frequently reported specific device problem is “Application Program Problem: Power Calculation Error” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem7
- Application Program Problem: Power Calculation Error1
Patient problems
- Blurred Vision4
- Visual Disturbances4
- Visual Impairment2
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
InjurySep 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A NON HEALTH CARE PROFESSIONAL REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE PATIENT WAS BOTHERED BY HALOS. CLINICAL REASON BEING MENTIONED AS DYSPHOTOPSIA. THE IOL WAS EXPLANTED AND EXCHANGED WITH AN UNKNOWN LENS IN THE SECONDARY IMPLANT PROCEDURE. ADDITIONAL INFORMATION HAS BEEN REQUESTED.
Patient problems: Visual Disturbances
MAUDE report 22993733 ↗InjuryAug 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A NON HEALTHCARE PROFESSIONAL REPORTED THAT, AFTER INTRAOCULAR LENS IMPLANTATION SURGERY, THE PATIENT EXPERIENCED STARBURST, GLARE AND HALOS AROUND LIGHT AND IT TAKES AN HOUR OR TWO IN THE MORNING FOR VISION TO COME INTO FOCUS FOR HIM TO READ OR DRIVE. HENCE THE LENS WAS EXPLANTED AND REPLACED WITH NON COMPANY MONOFOCAL LENS IN A SECONDARY PROCEDURE AND THE PATIENT WAS DOING WELL. CLINICAL REASON FOR EXPLANT WAS DUE TO PATIENT'S LIFESTYLE WORK AND DRIVING AT NIGHT SO THE PATIENT CANNOT SUCCESSFULLY NEUROADAPT. THERE WAS NO FURTHER IMPACT TO THE PATIENT. THERE ARE TWO MEDICAL REPORTS ASSOCIATED WITH THIS PATIENT. THIS FILE BELONGS TO LEFT EYE.
Patient problems: Visual Disturbances
MAUDE report 22791693 ↗InjuryAug 12, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A NON HEALTHCARE PROFESSIONAL REPORTED THAT, AFTER INTRAOCULAR LENS IMPLANTATION SURGERY, THE PATIENT EXPERIENCED STARBURST, GLARE AND HALOS AROUND LIGHT AND IT TAKES AN HOUR OR TWO IN THE MORNING FOR VISION TO COME INTO FOCUS FOR HIM TO READ OR DRIVE. THE GLARE, HALOS, AND STARBURSTS WAS A PROBLEM FOR THE PATIENT TO DRIVE AT NIGHT. THERE ARE TWO MEDICAL REPORTS ASSOCIATED WITH THIS PATIENT. THIS FILE BELONGS TO RIGHT EYE.
Patient problems: Visual Disturbances
MAUDE report 22783800 ↗InjuryMay 1, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A NON-HEALTHCARE PROFESSIONAL REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, EXPLANTED LENS WITH PATIENT REASON AND CLINICAL REASON WAS NOT TOLERATING LENS. THE IOL WAS EXCHANGED FOR ADVANCED TECHNOLOGY INTRAOCULAR LENSES (ATIOL) 1 YEAR 2 MONTHS AND 28 DAYS FOLLOWING THE INITIAL IMPLANT PROCEDURE.
Patient problems: Visual Impairment
MAUDE report 21942173 ↗InjuryJan 30, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A NURSE REPORTED THAT AFTER SURGERY THAT THE PATIENT EXPERIENCED HAZE FROM DAY 1, SO THE LENS WAS EXPLANTED IN A SECONDARY PROCEDURE AND KEPT IN A STERILE CUP WITH STERILE SALINE THEN WANTS TO CHECK FOR THE DEFECT. ADDITIONAL INFORMATION HAS BEEN REQUESTED.
Patient problems: Blurred Vision
MAUDE report 21272964 ↗InjuryApr 16, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A NON-HEALTHCARE PROFESSIONAL REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE PATIENT EXPERIENCED WITH FOGGY VISION, HARD SEEING AT ALL RANGES. THE LENS WAS EXCHANGED FOR UNSPECIFIED MONOFOCAL LENS MODEL 4 MONTHS 26 DAYS FOLLOWING THE INITIAL PROCEDURE. CLINICAL REASON FOR EXPLANT WAS MENTIONED AS FAILURE TO ADAPT. THERE ARE TWO MEDICAL DEVICE REPORTS ASSOCIATED WITH THIS PATIENT. THIS REPORT IS ASSOCIATED WITH THE RIGHT EYE. ADDITIONAL INFORMATION HAS BEEN RECEIVED AND STATED THAT PATIENT ISSUES RESOLVED WITH IOL EXCHANGE AND SURGEON PROGNOSIS WAS GOOD. NO PATIENT HARM WAS REPORTED.
Patient problems: Blurred Vision; Visual Impairment
MAUDE report 19116775 ↗InjuryOct 19, 2023Application Program Problem: Power Calculation Error; Application Program Problem: Power Calculation Error
A FACILITY REPRESENTATIVE REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE PATIENT EXPERIENCED BLURRED VISION . THE IOL WAS EXCHANGED FOR ANOTHER LENS MODEL 2 MONTHS FOLLOWING THE INITIAL IMPLANT PROCEDURE. THE CLINICAL REASON FOR EXPLANT MENTIONED AS WRONG POWER LENS. ADDITIONAL INFORMATION HAS BEEN REQUESTED.
Patient problems: Blurred Vision
MAUDE report 17965789 ↗InjuryOct 4, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A NURSE REPORTED THAT AN INTRAOCULAR LENS (IOL) WAS EXPLANTED A MONTH AFTER IMPLANTATION DUE TO PATIENT SEEING DOUBLE VISION AND BLURRY VISION. THE LENS WAS REPLACED WITH A NON COMPANY LENS. ADDITIONAL INFORMATION WAS REQUESTED AND RECEIVED STATING THE PATIENT SEE SHADOWS BEHIND LETTERS (WHEN READING TEXT). THE PATIENT'S SYMPTOMS WERE RESOLVED POST IOL REPLACEMENT.
Patient problems: Blurred Vision; Visual Disturbances
MAUDE report 17866992 ↗
Other intraocular lens devices
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens146 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens145 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens144 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens139 reports
- TECNIS SIMPLICITY DIB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens1 recall81 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens129 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens127 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens126 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page