AcrySof® IQ PanOptix® Toric Trifocal IOL TFNT40 (REF TFNT40U205)Recalls & reported problems

Alcon Laboratories, Inc. · AcrySof® IQ PanOptix® Toric Trifocal intraocular lenses (IOLs) are ultraviolet absorbing and blue light filtering foldable multifocal IOLs · Class 3 · Implant

All models of AcrySof IQ PanOptix Toric Trifocal IOL (165)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00380652416061), received between Sep 7, 2021 and Oct 29, 2025 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Material Deformation” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Material Deformation1
  • Material Discolored1
  • Material Opacification1

Patient problems

  • Visual Impairment2
  • Visual Disturbances1
  • Vitreous Floaters1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 29, 2025Material Opacification; Material Deformation; Material Opacification; Material Deformation

    A PHYSICIAN REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, PATIENT EXPERIENCED GLISTENINGS AND FEELS LIKE HIS VISION WAS GETTING WORSE. THERE WAS SOME SORT OF HAZINESS OVER THE POSTERIOR ASPECT OF THE LENS. THE PATIENT HAD YAG (YTTRIUM ALUMINUM GARNET) PROCEDURE AND POSSIBLY VITRECTOMY FOR FLOATERS. ADDITIONAL INFORMATION WAS RECEIVED, IN THE SURGEON PROGNOSIS OVERALL OCULAR HEALTH WAS NORMAL. THE GLISTENINGS ON THE POSTERIOR SURFACE OF THE INTRAOCULAR LENS (IOL) SEEM TO BE LIMITING VISION. THERE ARE TWO MEDICAL DEVICE REPORTS ASSOCIATED WITH THIS PATIENT. THIS REPORT IS ASSOCIATED WITH THE RIGHT EYE.

    Patient problems: Visual Impairment; Vitreous Floaters

    MAUDE report 23413679 ↗
  • InjuryMar 5, 2024Material Discolored; Material Discolored

    A NON HEALTHCARE PROFESSIONAL REPORTED THAT, AFTER INTRAOCULAR LENS IMPLANTATION SURGERY, THE PATIENT EXPERIENCED POOR VISION. HENCE THE LENS WAS EXPLANTED AND REPLACED WITH ANOTHER LENS IN A SECONDARY PROCEDURE. THE CLINICAL REASON FOR EXPLANT WAS OTHER MECHANICAL COMPLICATIONS OF LENS, PIGMENT ON LENS. ADDITIONAL INFORMATION WAS RECEIVED STATING THAT, THERE WAS PATIENT HARM. THE DIAGNOSIS OF THE HARM WAS CORNEAL EDEMA SECONDARY TO LENS EXCHANGE. IN THE SURGEON'S OPINION, THE PROGNOSIS IS SUSPECTED VISUAL IMPROVEMENT ONCE CORNEAL EDEMA SUBSIDES.

    Patient problems: Visual Impairment

    MAUDE report 18836136 ↗
  • InjurySep 7, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ADDITIONAL INFORMATION WAS RECEIVED STATING THE PATIENT WAS NOT HOSPITALIZED FOR THE EVENT AND THERE WAS NO PATIENT HARM.

    Patient problems: Visual Disturbances

    MAUDE report 12434408 ↗

Other Lens, multifocal intraocular devices

All Lens, multifocal intraocular devices →