AcrySof™ IQ PanOptix™ Toric UV IOL TFAT40 (REF TFAT40.285)Recalls & reported problems
Alcon Laboratories, Inc. · AcrySof® IQ PanOptix® Toric Trifocal intraocular lenses (IOLs) are ultraviolet absorbing foldable multifocal IOLs · Class 3 · Implant
All models of AcrySof IQ PanOptix Toric UV IOL (120)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00380652419406), received between Sep 8, 2021 and Sep 8, 2021 — classified as 1 injury.
The most frequently reported specific device problem is “Contamination” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Contamination1
Patient problems
- Visual Impairment1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 8, 2021Contamination; Contamination
A FACILITY REPRESENTATIVE REPORTED FOLLOWING THE INTRAOCULAR LENS (IOL) IMPLANTATION, THE PATIENT HAD EXPERIENCED CLOUDY VISION AND THERE WERE DEPOSITS ON POSTERIOR SURFACE OF IOL. THE PATIENT IS ALSO SCHEDULED FOR A PLANNED EXPLANT. ADDITIONAL INFORMATION WAS RECEIVED THAT THE LENS WAS EXPLANTED IN A SECONDARY PROCEDURE WITH NO HARM TO THE PATIENT. THE PATIENT WAS NOT HOSPITALIZED AS A RESULT OF THE EVENT AND THE PROGNOSIS WAS GOOD. THE SURGERY WAS COMPLETED BY USING A REPLACEMENT LENS.
Patient problems: Visual Impairment
MAUDE report 12437858 ↗
Other Lens, multifocal intraocular devices
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular144 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular1 recall66 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular113 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular112 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular110 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular107 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular104 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular93 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page