AcrySof™ IQ Vivity™ DFT015 (REF DFT015.145)Recalls & reported problems
Alcon Laboratories, Inc. · Sterile UV and Blue Light Filtering Acrylic Foldable Aspheric Wavefront-Shaping Posterior Chamber Intraocular Lens · Class 3 · Implant
All models of AcrySof IQ Vivity (225)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 10
- Deaths reported
- 0
- Injuries reported
- 8
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00380652421126), received between Nov 30, 2021 and Aug 23, 2024 — classified as 8 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Crack” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem7
- Crack1
- Insufficient Device Problem Information1
- Scratched Material1
Patient problems
- Blurred Vision4
- Insufficient Information3
- Visual Disturbances3
- Visual Impairment3
- Eye Pain2
- Headache2
- Dry Eye(s)1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
InjuryAug 23, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
UPON FURTHER REVIEW OF THE COMPLAINT, THE PATIENT HAD EXPERIENCED BLURRY VISION, GLARE, PAIN AND HEADACHES AFTER LENS IMPLANTATION. THE PATIENT WAS UNHAPPY AFTER IMPLANTATION. HOWEVER, THE LENS WAS NOT EXPLANTED.
Patient problems: Blurred Vision; Eye Pain; Headache; Visual Disturbances
MAUDE report 20053597 ↗InjuryAug 22, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ADDITIONAL INFORMATION HAS BEEN RECEIVED AND STATED THAT LENS WAS NOT EXPLANTED AND NO PLAN TO EXPLANT.
Patient problems: Blurred Vision; Eye Pain; Headache; Visual Disturbances
MAUDE report 20037193 ↗InjuryJul 3, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A NON-HEALTH CARE PROFESSIONAL REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, PATIENT STATES SINCE THEY TOOK THE PATCH OFF SHE SEES A BLURRED, SMUDGE ON THE PERIPHERY OF HER VISION. WHEN PATIENT LOOKS STRAIGHT IT IS PRETTY CLEAR, BUT WHEN PATIENT LOOKS LEFT OR RIGHT SHE SEES THE SMUDGE SPOT. PATIENT SURGEON SAW HER AT ONE DAY POST OP AND TOLD HER EVERYTHING WAS FINE BUT HER EYES WERE DRY AND TO USE ARTIFICIAL TEARS. ADDITIONAL INFORMATION WAS REQUESTED.
Patient problems: Dry Eye(s); Visual Disturbances
MAUDE report 19664019 ↗InjuryDec 30, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A PHYSICIAN REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE PATIENT VISION WAS AT ADDITION +2 AND .75 CYL. ADDITIONAL INFORMATION RECEIVED AND STATED THAT, THE PATIENT IS NOT SATISFIED NEAR VISION.
Patient problems: Blurred Vision; Visual Impairment
MAUDE report 16076678 ↗MalfunctionOct 14, 2022Crack; Crack
A NON-HEALTHCARE PROFESSIONAL REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, LENS WAS CRACKED, NOTICED UPON INSERTION. LENS WAS REMOVED AND REPLACED WITH THE BACKUP LENS DURING INITIAL PROCEDURE. ADDITIONAL INFORMATION WAS REQUESTED AND INDICATED THAT THAT THE SURGICAL INTERVENTION REQUIRED AS A RESULT OF THIS EVENT WAS TO REMOVE THE LENS AND REPLACED WITH UNDAMAGED LENS. NO PATIENT HARM WAS REPORTED. PATIENT WAS NOT HOSPITALIZED AS A RESULT OF THIS EVENT. DOCTOR¿S PROGNOSIS WAS INDICATED AS ¿NO HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15605433 ↗MalfunctionSep 28, 2022Scratched Material; Scratched Material
A FACILITY REPRESENTATIVE REPORTED A SCRATCH ON THE LENS. ADDITIONAL INFORMATION WAS RECEIVED STATING THEY FOUND A SCRATCH ON THE IMPLANT AFTER THE LENS WAS INSERTED.
Patient problems: Insufficient Information
MAUDE report 15500974 ↗InjuryJul 29, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A NURSE REPORTED FOLLOWING AN INTRAOCULAR LENS IMPLANT PROCEDURE, THE PATIENT EXPERIENCED POOR QUALITY OF VISION. THE LENS WAS LATER EXCHANGED IN A SECONDARY PROCEDURE. ADDITIONAL INFORMATION HAS BEEN REQUESTED.
Patient problems: Visual Impairment
MAUDE report 15130533 ↗InjuryJun 23, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A PHYSICIAN REPORTED FOLLOWING AN INTRAOCULAR LENS IMPLANT PROCEDURE, THE PATIENT EXPERIENCED MYOPIC SURPRISE AND WAS NOT HAPPY WITH THE NEAR VISION. THE LENS WAS EXCHANGED IN A SECONDARY PROCEDURE. ADDITIONAL INFORMATION HAS BEEN REQUESTED.
Patient problems: Blurred Vision; Visual Impairment
MAUDE report 14787013 ↗InjuryMay 27, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE FACILITY REPORTED THAT, FOLLOWING INTRAOCULAR LENS IMPLANT PROCEDURE, THE LENS WAS EXCHANGED DUE TO MECHANICAL COMPLICATION. ADDITIONAL INFORMATION WAS REQUESTED.
Patient problems: Insufficient Information
MAUDE report 14523237 ↗InjuryNov 30, 2021Insufficient Device Problem Information; Insufficient Device Problem Information
A CLINIC MANAGER REPORTED THAT APPROXIMATELY TWO MONTHS FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE LENS WAS REMOVED. ADDITIONAL INFORMATION WAS REQUESTED.
Patient problems: Insufficient Information
MAUDE report 12897124 ↗
FDA clearance and classification
The FDA regulates product code POE (extended depth of focus intraocular lens) under 21 CFR 886.3600 as a Class III device. 21 CFR 886.3600 ↗
Devices of this type need premarket approval (PMA), the FDA's most demanding review, usually with clinical data.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
FDA definition of this device type: Intended to be implanted to replace the natural lens of an eye.
Common questions about the AcrySof™ IQ Vivity™ DFT015
Has the AcrySof™ IQ Vivity™ DFT015 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00380652421126), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the AcrySof™ IQ Vivity™ DFT015?
The FDA's MAUDE database lists 10 adverse event reports for this device, received between Nov 30, 2021 and Aug 23, 2024. In those reports, the most common specific device problems are “Crack” (1) and “Scratched Material” (1); the most common patient problems are “Blurred Vision” (4), “Visual Disturbances” (3) and “Visual Impairment” (3). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the AcrySof™ IQ Vivity™ DFT015?
None of the reports are classified as deaths, 8 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the AcrySof™ IQ Vivity™ DFT015 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the AcrySof™ IQ Vivity™ DFT015, and is it still sold?
The FDA's device database lists Alcon Laboratories, Inc. as the company responsible for it (brand AcrySof™ IQ Vivity™, model DFT015). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Extended depth of focus intraocular lens devices
- TECNIS IOL ZXR00Johnson & Johnson Surgical Vision, Inc. · Extended depth of focus intraocular lens101 reports
- TECNIS IOL ZXR00Johnson & Johnson Surgical Vision, Inc. · Extended depth of focus intraocular lens1 recall49 reports
- TECNIS IOL ZXR00Johnson & Johnson Surgical Vision, Inc. · Extended depth of focus intraocular lens93 reports
- TECNIS IOL ZXR00Johnson & Johnson Surgical Vision, Inc. · Extended depth of focus intraocular lens89 reports
- TECNIS IOL ZXR00Johnson & Johnson Surgical Vision, Inc. · Extended depth of focus intraocular lens87 reports
- TECNIS IOL ZXR00Johnson & Johnson Surgical Vision, Inc. · Extended depth of focus intraocular lens75 reports
- TECNIS IOL ZXR00Johnson & Johnson Surgical Vision, Inc. · Extended depth of focus intraocular lens73 reports
- TECNIS IOL ZXR00Johnson & Johnson Surgical Vision, Inc. · Extended depth of focus intraocular lens71 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page