AcrySof™ IQ PanOptix™ UV IOL TFAT00 (REF TFAT00.120)Recalls & reported problems

Alcon Laboratories, Inc. · The AcrySof® IQ PanOptix® UV Absorbing Trifocal intraocular lenses (IOLs) are ultraviolet absorbing foldable multifocal IOLs · Class 3 · Implant

All models of AcrySof IQ PanOptix UV IOL (28)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00380652429559), received between Dec 8, 2022 and May 19, 2026 — classified as 3 injuries.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3

Patient problems

  • Visual Impairment2
  • Blurred Vision1
  • UGH (Uveitis Glaucoma Hyphema) Syndrome1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 19, 2026Adverse Event Without Identified Device or Use Problem

    A NON-HEALTH CARE PROFESSIONAL REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THERE WAS A TEAR IN THE POSTERIOR CAPSULE (PC). HOWEVER, THE SURGEON OPTED TO CONTINUE ON COURSE AND IMPLANT THE COMPANY IOL INTO THE SULCUS. FOLLOWING THE PROCEDURE, THE PATIENT DEVELOPED UVEITIS GLAUCOMA HYPHEMA (UGH) SYNDROME DUE TO THE SINGLE PIECE IOL BEING IN THE SULCUS. THE IOL WAS EXCHANGED FOR UNSPECIFIED 3-PIECE MONOFOCAL IOL IN A SECONDARY PROCEDURE. ADDITIONAL INFORMATION HAS BEEN REQUESTED, RECEIVED AND STATED IN THE SURGEON¿S OPINION, PRODUCT DID NOT CAUSE THE EVENT, IT WAS THE LOCATION OF THE PRODUCT IN THE SULCUS THAT WAS THE ISSUE. IT WAS MENTIONED IF THERE WOULD NOT HAVE BEEN A PC TEAR/BAG BREAK, THIS WOULDN'T BE AN ISSUE, BUT THE SURGEON HAD NO CHOICE BUT TO PLACE IN SULCUS, THAT WAS THE ISSUE. THE LENS WAS EXCHANGED WITH NON-COMPANY LENS. THERE WAS NO FURTHER IMPACT TO THE PATIENT AND HEALING WELL WITH IOL IN GOOD POSITION.

    Patient problems: UGH (Uveitis Glaucoma Hyphema) Syndrome

    MAUDE report 25216001 ↗
  • InjuryDec 12, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A NURSE REPORTED FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE PATIENT EXPERIENCED DYSPHOTOPSIA. THE LENS WAS EXPLANTED AND REPLACED WITH MONOFOCAL LENS IN A SECONDARY PROCEDURE. THE CLINICAL REASON FOR THE EXPLANT WAS DYSPHOTOPSIA. ADDITIONAL INFORMATION WAS REQUESTED, BUT FURTHER NO INFORMATION WAS AVAILABLE.

    Patient problems: Visual Impairment

    MAUDE report 15959609 ↗
  • InjuryDec 8, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A NON-HEALTHCARE PROFESSIONAL REPORTED FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE PATIENT EXPERIENCED BLURRY VISION AT ALL DISTANCES. THE LENS WAS EXPLANTED IN A SECONDARY PROCEDURE. ADDITIONAL INFORMATION WAS REQUESTED AND RECEIVED STATING THE PATIENT'S CYLINDRICAL VALUE INCREASED POST SURGERY.

    Patient problems: Blurred Vision; Visual Impairment

    MAUDE report 15939397 ↗

Other Lens, multifocal intraocular devices

All Lens, multifocal intraocular devices →