Clareon CCW0T4 (UDI 00380652432870)Recalls & reported problems

Alcon Laboratories, Inc. · CLAREON TORIC UVA · Class 3 · Implant

All models of Clareon (1142)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00380652432870), received between Oct 30, 2023 and Aug 12, 2026 — classified as 3 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Defective Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Defective Device1
  • Material Deformation1
  • Scratched Material1

Patient problems

  • Insufficient Information3
  • Visual Impairment3
  • Blurred Vision1
  • Visual Disturbances1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 12, 2026Material Deformation

    Patient problems: Insufficient Information

    MAUDE report 50221885 ↗
  • InjuryJul 30, 2026Adverse Event Without Identified Device or Use Problem

    A non-health care professional reported that following an intraocular lens (IOL) implantation procedure, the patient ended more myopic than predicted. Subsequently the lens was removed and replaced with an unspecified advanced technology intraocular lens (ATIOL) in a secondary procedure. The clinical reason for explant was refractive surprise due to duanes syndrome.Additional information has been requested but is not available at the time of this report.

    Patient problems: Visual Impairment

    MAUDE report 50086130 ↗
  • InjuryJan 30, 2026Adverse Event Without Identified Device or Use Problem

    A NON-HEALTHCARE PROFESSIONAL REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE PATIENT EXPERIENCED WITH SEVERE POSITIVE DYSPHOTOPSIA. THE LENS WAS EXCHANGED FOR ANOTHER LENS MODEL 03 MONTHS 28 DAYS FOLLOWING THE INITIAL PROCEDURE. CLINICAL REASON FOR EXPLANT WAS MENTIONED AS REFRACTIVE SURPRISE. ADDITIONAL INFORMATION WAS REQUESTED. A QUESTIONNAIRE WAS RECEIVED.

    Patient problems: Visual Disturbances; Visual Impairment

    MAUDE report 24222174 ↗
  • MalfunctionJan 3, 2025Scratched Material; Scratched Material

    A NON-HEALTHCARE PROFESSIONAL REPORTED DURING INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, SIGNIFICANT SCRATCHES LARGE AND CRACK LIKE. SEASONED TECH WAS IN THE ROOM AND LENSES WERE LOADED JUST BEFORE IMPLANTATION. ADDITIONAL INFORMATION HAS BEEN REQUESTED. THERE ARE SIX MEDICAL DEVICE REPORTS ASSOCIATED WITH THIS COMPLIANT. THIS REPORT IS 3 OF 6.

    Patient problems: Insufficient Information

    MAUDE report 21066470 ↗
  • MalfunctionOct 23, 2024Defective Device; Defective Device

    A NON-HEALTHCARE PROFESSIONAL REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, PHYSICIAN NOTED IT WAS DEFECTIVE NOT MALUABLE. SUBSEQUENTLY THE LENS WAS REMOVED DURING INITIAL PROCEDURE. ADDITIONAL INFORMATION HAS BEEN REQUESTED.

    Patient problems: Insufficient Information

    MAUDE report 20516812 ↗
  • InjuryOct 30, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A FACILITY REPRESENTATIVE REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE PATIENT EXPERIENCED BLURRED VISION, CLINICAL REASON FOR EXPLANT BEING MECHANICAL COMPLICATION OF IOL WITH REFRACTIVE SURPRISE. THE IOL WAS EXPLANTED AND EXCHANGED FOR AN UNKNOWN ATIOL FOLLOWING THE INITIAL IMPLANT PROCEDURE. ADDITIONAL INFORMATION HAS BEEN REQUESTED.

    Patient problems: Blurred Vision; Visual Impairment

    MAUDE report 18028812 ↗

Other intraocular lens devices

All intraocular lens devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page