Alcon 8065480120Recalls & reported problems
Alcon Laboratories, Inc. · Microsurgical Instrument VISCOAT CANNULA 27GA THREADED HUB · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00380654801209), received between Dec 1, 2022 and Sep 21, 2024 — classified as 1 injury, 3 malfunctions.
The most frequently reported specific device problem is “Complete Blockage” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Complete Blockage1
- Fitting Problem1
- Obstruction of Flow1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Corneal Clouding/Hazing1
- Corneal Edema1
- Insufficient Information1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 21, 2024Obstruction of Flow; Obstruction of Flow
A PHYSICIAN REPORTED THAT AN OPHTHALMIC PLUNGER WAS PRESSED BUT COULD NOT BE PUSHED AND NO CHEMICAL SOLUTION CAME OUT BEFORE SURGERY. DETAILS OF PROCEDURE AND PATIENT HARM WAS NOT REPORTED.
Patient problems: Insufficient Information
MAUDE report 20275140 ↗MalfunctionOct 3, 2023Fitting Problem; Fitting Problem
A CUSTOMER REPORTED THAT DURING THE SURGERY AN OPHTHALMIC OPERATING SOFT TIP CANNULA WAS DIFFICULTY ENTERING THROUGH THE VALVED TROCAR. THERE WAS NO DETAILS OF PROCEDURE AND PATIENT DETAILS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17860900 ↗MalfunctionJan 27, 2023Complete Blockage; Complete Blockage
A CUSTOMER REPORTED THAT DURING CATARACT SURGERY CANNULA WAS BLOCKED THE PROCEDURE WAS COMPLETED ON THE SAME DAY WITHOUT ANY PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16252565 ↗InjuryDec 1, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A LITERATURE ARTICLE REVEALED THAT WHILE TREATING A PATIENT BEFORE ENTERING THE ANTERIOR CHAMBER, OPHTHALMIC VISCOSURGICAL DEVICE WAS ACCIDENTALLY INJECTED INTO THE CORNEAL STROMA, LEAVING A 4MM OPACITY SUPERONASAL WITHIN 4 MM OF THE CENTRAL CORNEA, ON THE FIRST POSTOPERATIVE DAY VISION IMPROVED AND THERE WAS MILD SUPERIOR CORNEAL EDEMA, BY WEEKS AFTER SURGERY THE VISUAL ACUITY IMPROVED. THE CANNULA USED TO INJECT VISCOELASTIC MAY HAD CONTRIBUTED TO THE REPORTED EVENT. NO FURTHER INFORMATION EXPECTED DUE TO UNLIKELIHOOD.
Patient problems: Corneal Clouding/Hazing; Corneal Edema
MAUDE report 15898932 ↗
Other Cannula, ophthalmic devices
- iTrack Advance iTrack-ADSNova Eye, Inc. · Cannula, Ophthalmic53 reports
- iTrack 250ANova Eye, Inc. · Cannula, Ophthalmic1 recall2 reports
- Vortex Surgical Inc VS0200.25Vortex Surgical, Inc. · Cannula, Ophthalmic1 recall0 reports
- Vortex Surgical Inc VS0275.27Vortex Surgical, Inc. · Cannula, Ophthalmic1 recall0 reports
- Vortex Surgical Inc VS0220.25Vortex Surgical, Inc. · Cannula, Ophthalmic1 recall0 reports
- Visitec® 585278Beaver-Visitec International, Inc. · Cannula, Ophthalmic1 recall0 reports
- Vortex Surgical Inc VS0205.23Vortex Surgical, Inc. · Cannula, Ophthalmic1 recall0 reports
- Vortex Surgical Inc VS0250.25Vortex Surgical, Inc. · Cannula, Ophthalmic1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page