- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00380655095690), received between Oct 27, 2021 and Aug 22, 2025 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
- Appropriate Device Problem Term/Code Not Available1
- Failure to Advance1
- Failure to Deliver1
- Failure to Fold1
Patient problems
- Insufficient Information2
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 22, 2025Failure to Deliver; Failure to Deliver
A FACILITY REPRESENTATIVE REPORTED DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE LENS DID NOT DEPLOY WHEN USED. ADDITIONAL INFORMATION WAS REQUESTED.
Patient problems: Insufficient Information
MAUDE report 22872905 ↗MalfunctionJan 30, 2024Break; Break
A NON HEALTHCARE PROFESSIONAL REPORTED THAT DURING THE INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE THE LENS WAS BROKEN UPON INSERTION. THE LENS WAS REMOVED AND REPLACED WITH NEW LENS DURING THE INITIAL PROCEDURE. THERE WAS NO PATIENT HARM REPORTED. ADDITIONAL INFORMATION HAS BEEN REQUESTED
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18605859 ↗MalfunctionFeb 9, 2023Break; Failure to Advance; Break; Failure to Advance
AN OPHTHALMOLOGIST REPORTED THAT DURING A CATARACT EXTRACTION WITH AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THIS EVENT OCCURRED HALF WAY LOADING INTO THE EYE, BUT GOT STUCK BEFORE FULL INSERTION. THE IOL AND NOZZLE HAVE CONTACT WITH PATIENT, THE NOZZLE AND LEADING HAPTIC WAS INSIDE THE AC, THEY PULL IT OUT SHORTLY CAUSE THE LENS COULD NOT DISLODGE. HAPTIC BROKEN DURING LENS DIALLING IN THE COMPANY INJECTOR. SURGERY WAS COMPLETED WITH ANOTHER COMPANY LENS. ADDITIONAL INFORMATION WAS REQUESTED, BUT NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: Insufficient Information
MAUDE report 16333053 ↗MalfunctionOct 27, 2021Failure to Fold; Appropriate Device Problem Term/Code Not Available; Failure to Fold; Appropriate Device Problem Term/Code Not Available
A NURSE REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE LENS WOULD NOT LOAD AND FOLD PROPERLY. THERE WAS NO PATIENT HARM AND PATIENT WAS NOT HOSPITALIZED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12706675 ↗
Other intraocular lens devices
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens146 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens145 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens144 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens139 reports
- TECNIS SIMPLICITY DIB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens1 recall81 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens129 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens127 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens126 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page