Skip to content

Clareon PanOptix Pro PXCWT3 (REF PXCWT3.210)Recalls & reported problems

Alcon Laboratories, Inc. · CLAREON PANOPTIX PRO TORICUV · Class 3 · Implant

All models of Clareon PanOptix Pro (222)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00380658433987), received between Jun 18, 2025 and Jun 18, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Dislodged or Dislocated1

Patient problems

  • Blurred Vision1
  • Conjunctivitis1
  • Corneal Edema1
  • Eye Pain1
  • Inflammation1
  • Intraocular Pressure Increased1
  • Red Eye(s)1
  • Toxic Anterior Segment Syndrome (TASS)1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 18, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated

    A NURSE REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE PATIENT HAD TASS (TOXIC ANTERIOR SEGMENT SYNDROME) ONE DAY POST OP, WITH INFLAMMATION CONFINED TO THE ANTERIOR CHAMBER. UNSPECIFIED TOPICAL STEROIDS WERE STARTED AND FOLLOW UP HAS BEEN SCHEDULED. ADDITIONAL INFORMATION HAS BEEN REQUESTED, RECEIVED AND STATED TASS ONSET WAS SEEN A POST-OP DAY 1. CULTURES WERE NOT DONE. CONJUNCTIVAL INFLAMMATION, AQUEOUS CELLS AND AQUEOUS FIBRIN WERE PRESENT. POST OP DAY 6, THE PATIENT HAD EYE PAIN, TRACE CORNEAL EDEMA AND SCLERAL REDNESS. MEDICATION ADJUSTMENTS WERE MADE, NOTED POTENTIAL FOR SURGICAL INTERVENTION OF LENS ROTATION DUE TO BLURRY VISION FROM 031 DEGREE TO 180 DEGREE. INFLAMMATION & FIBRIN IMPROVING. (B)(6) 2025 VISIT VISUAL ACUITY 20/40, INTRAOCULAR PRESSURE WAS NOTED AS INCREASED AND TREATED TOPICALLY WITH UNSPECIFIED MEDICATION. ADDITIONALLY, SURGEON STATED THERE WAS NOTHING OUT OF THE ORDINARY OR SIGNIFICANT TO BE NOTED AS FAR AS THE SURGICAL PROCESS WAS CONCERNED. ALL STERILIZATION RECORDS WERE SUFFICIENT AND WITHIN PARAMETERS. NO BREAKS IN PROCESS OR POLICY WERE NOTED. SO FAR THIS REMAINS AN ISOLATED INSTANCE.

    Patient problems: Blurred Vision; Conjunctivitis; Corneal Edema; Eye Pain; Inflammation; Intraocular Pressure Increased; Red Eye(s); Toxic Anterior Segment Syndrome (TASS)

    MAUDE report 22283244 ↗

Other Lens, Multifocal Intraocular devices

All Lens, Multifocal Intraocular devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page