Clareon PanOptix Pro PXCAT0 (REF PXCAT0.175)Recalls & reported problems

Alcon Laboratories, Inc. · CL PANOPTIX PRO ATME UVA · Class 3 · Implant

All models of Clareon PanOptix Pro (222)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00380658490294), received between Jul 21, 2025 and Jul 3, 2026 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Device Dislodged or Dislocated1
  • Use of Incorrect Control/Treatment Settings1

Patient problems

  • Blurred Vision1
  • Insufficient Information1
  • Visual Disturbances1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 3, 2026Adverse Event Without Identified Device or Use Problem

    A NON-HEALTH CARE PROFESSIONAL REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANTATION PROCEDURE, THE PATIENT EXPERIENCED BLURRY VISION. CLINICAL REASON BEING MENTIONED AS DYSPHOTOPSIA. THE IOL WAS EXPLANTED AND EXCHANGED FOR A NON-COMPANY LENS IN THE SECONDARY IMPLANT PROCEDURE. ADDITIONAL INFORMATION WAS RECEIVED STATING THAT THERE WERE NO FURTHER CONSEQUENCES TO THE PATIENT.

    Patient problems: Visual Disturbances

    MAUDE report 25704830 ↗
  • InjuryMay 29, 2026Adverse Event Without Identified Device or Use Problem

    A NON-HEALTHCARE PROFESSIONAL REPORTED THAT FOLLOWING INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, PATIENT HAD POOR VISUAL QUALITY. THE LENS WAS EXCHANGED FOR AN UNKNOWN MONOFOCAL IOL AFTER THE INITIAL IMPLANT PROCEDURE. ADDITIONAL INFORMATION HAS BEEN REQUESTED.

    Patient problems: Blurred Vision

    MAUDE report 25328618 ↗
  • MalfunctionJul 21, 2025Use of Incorrect Control/Treatment Settings; Device Dislodged or Dislocated; Use of Incorrect Control/Treatment Settings; Device Dislodged or Dislocated

    A FACILITY REPRESENTATIVE REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, EXPLANTED IOL WITH REASON WRONG AXIS. CLINICAL REASON FOR THE EXPLANT IS IOL NOTED TO BE SUBLUXED INFERIORLY. THE LENS WAS REPLACED WITH DIFFERENT MODEL COMPANY LENS. ADDITIONAL INFORMATION WAS RECEIVED STATING AS PER THE SURGEON OPINION PATIENT HAD BEEN A RESTLESS SLEEPER SINCE SURGERY AND REPORT IT IS POSSIBLE, HE ACCIDENTALLY RUBBED OR MANIPULATING EYE HAS CONTRIBUTED TO THE CAUSE OF EVENT. PATIENT SYMPTOMS WERE STILL CONTINUING.

    Patient problems: Insufficient Information

    MAUDE report 22559649 ↗

Other Lens, Multifocal Intraocular devices

All Lens, Multifocal Intraocular devices →