Clareon PanOptix Pro PXCAT0 (REF PXCAT0.185)Recalls & reported problems

Alcon Laboratories, Inc. · CL PANOPTIX PRO ATME UVA · Class 3 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00380658490317), received between Jul 17, 2025 and Apr 24, 2026 — classified as 4 injuries.

The most frequently reported specific device problem is “Material Deformation” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Material Deformation1

Patient problems

  • Blurred Vision2
  • Eye Injury1
  • Hyphema1
  • Insufficient Information1
  • Iritis1
  • Red Eye(s)1
  • Visual Impairment1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 24, 2026Adverse Event Without Identified Device or Use Problem

    A FACILITY REPRESENTATIVE REPORTED THAT FOLLOWING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, THE PATIENT EXPERIENCED BLURRED VISION AFTER LENS IMPLANTED AND CLINICAL REASON FOR EXPLANT BEING DOCTOR SUGGESTED TO DO AN EXCHANGE WITH AN LRI. THE IOL WAS EXPLANTED AND EXCHANGED FOR A NON COMPANY LENS FOLLOWING THE INITIAL IMPLANT PROCEDURE. THERE WAS NO FURTHER IMPACT TO THE PATIENT. ADDITIONAL INFORMATION HAS BEEN REQUESTED BUT IS NOT AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Blurred Vision

    MAUDE report 24979962 ↗
  • InjuryFeb 16, 2026Adverse Event Without Identified Device or Use Problem

    A NON-HEALTHCARE PROFESSIONAL REPORTED THAT FOLLOWING THE INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE THE PATIENT WAS DISSATISFIED. THE LENS WAS EXPLANTED IN A SECONDARY PROCEDURE. ADDITIONAL INFORMATION HAD BEEN REQUESTED. THERE ARE TWO MEDICAL REPORTS ASSOCIATED WITH THIS PATIENT. THIS FILE IS FOR RIGHT EYE.

    Patient problems: Insufficient Information

    MAUDE report 24343687 ↗
  • InjuryDec 2, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ADDITIONAL INFORMATION RECEIVED AND REPORTED THAT THE IOL WAS EXCHANGED FOR THE DIFFERENT LENS MODEL BUT HALF A DIOPTER MORE POWER INDICATING THE CORRECT LENS POWER WAS NOT IMPLANTED INITIALLY. THERE IS NO REPORTED DEFECT OR FAULT WITH THE IOL. THE PATIENT'S ISSUES WAS RESOLVED AND THERE WAS NO FURTHER IMPACT TO THE PATIENT. IN SURGEON¿S PROGNOSIS PATIENT CONDITION WAS GOOD.

    Patient problems: Blurred Vision; Visual Impairment

    MAUDE report 23690457 ↗
  • InjuryJul 17, 2025Material Deformation; Material Deformation

    A PHYSICIAN REPORTED THAT DURING INTRAOCULAR LENS IMPLANTATION SURGERY, THE SURGEON NOTICED THAT THE PATIENT HAD SOME FLOPPINESS TO THE IRIS AND IT WAS NOT DILATED WIDELY. BECAUSE OF THIS SURGEON COULD NOT INSERT THE TIP AS FAR INTO THE EYE AND SO MUCH PRESSURE WAS NEEDED TO KEEP THE TIP FROM BACKING OUT, THERE WAS SOME CHAMBER SHALLOWING AND THE INJECTION OF THE LENS TRAUMATIZED THE IRIS, SO THE PATIENT HAD AN IRIS DEFECT AND HYPHEMA. SCHEDULED PROCEDURE WAS COMPLETED THE SAME DAY AND THE LENS LEFT IMPLANTED. IN THE SURGEON¿S OPINION, CARTRIDGE TIP WAS TOO SHORT AND CANNOT BE INSERTED FAR ENOUGH INTO THE AC (ANTERIOR CHAMBER) IT CAUSED OR CONTRIBUTED TO THE EVENT. IN THE SURGEON¿S PROGNOSIS, THE PATIENT WAS SEEING WELL, BUT HAVE IRIS DEFECT AND IT WAS PERMANENT.

    Patient problems: Eye Injury; Hyphema; Iritis; Red Eye(s)

    MAUDE report 22531606 ↗

Other Lens, Multifocal Intraocular devices

All Lens, Multifocal Intraocular devices →