Skip to content

Clareon PanOptix Pro PXCAT0 (REF PXCAT0.190)Recalls & reported problems

Alcon Laboratories, Inc. · CL PANOPTIX PRO ATME UVA · Class 3 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00380658490324), received between Nov 24, 2025 and Sep 1, 2026 — classified as 3 injuries, 1 malfunction.

The most frequently reported specific device problem is “Material Twisted/Bent” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Material Twisted/Bent1

Patient problems

  • Blurred Vision3
  • Visual Disturbances2
  • No Clinical Signs, Symptoms or Conditions1
  • Visual Impairment1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjurySep 1, 2026Adverse Event Without Identified Device or Use Problem

    Patient problems: Blurred Vision; Visual Impairment

    MAUDE report 50543019 ↗
  • InjuryAug 7, 2026Adverse Event Without Identified Device or Use Problem

    A non health professional reported that following surgery, the patient experienced blurry visual acuity (VA), dysphotopsia left eye (OS). The clinical reason for explant was dysphotopsia. The IOL was replaced with an another company lens. As a result, the intraocular lens (IOL) was explanted 4 months, 4 days after the initial implant procedure.There are two medical reports associated with this patient. This file belongs to left eye.Additional information has been requested but is not available at the time of this report.

    Patient problems: Blurred Vision; Visual Disturbances

    MAUDE report 50175750 ↗
  • MalfunctionFeb 12, 2026Material Twisted/Bent

    A NON-HEALTH CARE PROFESSIONAL REPORTED THAT DURING AN INTRAOCULAR LENS (IOL) IMPLANT PROCEDURE, HAPTIC WAS BENT WHILE LOADING. THERE WAS NO PATIENT CONTACT AND THE SURGERY WAS COMPLETED ON THE SAME DAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24322343 ↗
  • InjuryNov 24, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A CONSUMER REPORTED EXPERIENCING LARGE HALOS AROUND HEADLIGHTS BOTH DURING DAY AND NIGHT FOLLOWING THE IMPLANTATION OF AN INTRAOCULAR LENS (IOL). THIS DISTORTION WAS CAUSING UNACCEPTABLE INTERFERENCE WITH SAFE DRIVING, ESPECIALLY AT NIGHT. BASED ON THE ADDITIONAL INFORMATION PROVIDED, THE PATIENT BEGAN EXPERIENCING SYMPTOMS IMMEDIATELY FOLLOWING CATARACT SURGERY. SHE DISCUSSED THESE CONCERNS WITH THE SURGEON, WHO ADVISED THAT THE SYMPTOMS MIGHT IMPROVE AFTER SIX MONTHS. THE PATIENT REPORTED THAT HER DISTANCE VISION WAS NOT PERFECTLY CORRECTED, PROMPTING HER TO CONSULT AN EYE CARE SPECIALIST FOR A NEW PRESCRIPTION. THE NEW GLASSES RESULTED IN EXCELLENT DISTANCE VISION, WHILE HALOS AROUND THE LIGHTS WERE ONLY SLIGHTLY CHANGED. THERE ARE TWO MEDICAL DEVICE REPORTS ASSOCIATED WITH THIS PATIENT. THIS REPORT IS ASSOCIATED WITH THE RIGHT EYE.

    Patient problems: Blurred Vision; Visual Disturbances

    MAUDE report 23630436 ↗

Other Lens, Multifocal Intraocular devices

All Lens, Multifocal Intraocular devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page