ARCHITECT 2P36-35Recalls & reported problems
Abbott GmbH · ARCHITECT HIV Ag/Ab Combo Reagent Kit · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00380740003906), received between Aug 24, 2020 and Aug 24, 2020 — classified as 1 malfunction.
The most frequently reported specific device problem is “False Positive Result” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- False Positive Result1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 24, 2020False Positive Result; False Positive Result
THE CUSTOMER REPORTED FALSE REACTIVE ARCHITECT (B)(6) AG/AB COMBO ASSAY RESULTS FOR A (B)(6) YEAR OLD MALE, WHO IS CURRENTLY TAKING THE MEDICATION TRUVADA. THE PATIENT DOES NOT DESCRIBE ANY RISK FACTORS AND TESTED NEGATIVE FOR (B)(6) IN (B)(6) 2019. THE CUSTOMER PROVIDED THAT ON (B)(6) 2020 RESULTS FOR THIS PATIENT WERE REACTIVE WITH ARCHITECT AND VIA AN ALTERNATE METHOD. ON (B)(6) 2020 SID (B)(6): INITIAL = 38.30 S/CO, REPEATS 58.45, 60.40 S/CO. ON (B)(6) 2020 THE SAMPLE WAS TESTED ON ANOTHER METHOD, GEENIUS: INITIAL TESTING RESULT WAS (B)(6) INDETERMINATE AND (B)(6) NONREACTIVE (GP41 PRESENT ONLY). REPEAT TESTING RESULTS WERE (B)(6) REACTIVE AND (B)(6) NONREACTIVE (GP41 & GP160 PRESENT). ON (B)(6) 2020 SID (B)(6) RESULTS = 0.22, 0.25, & 0.21 S/CO. ON (B)(6) 2020 (B)(6) INITIAL = 0.22 S/CO, REPEATS = 0.25, 0.21 S/CO AND SID (B)(6) INITIAL = 54.68, REPEAT = 52.46 S/CO. ARCHITECT (B)(6) AG/AB COMBO ASSAY INTERPRETATION RANGE: <1.00 S/CO = NONREACTIVE; => 1.00 S/CO = REACTIVE. THERE WAS NO IMPACT TO PATIENT MANAGEMENT REPORTED
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10446359 ↗
Other Test, hiv detection devices
- Determine™ HIV–1/2 Ag/Ab Combo 7D2648Alere Scarborough, Inc. · Test, Hiv Detection409 reports
- Alere Determine™ HIV–1/2 Ag/Ab Combo 7D2648Alere Scarborough, Inc. · Test, Hiv Detection238 reports
- Elecsys HIV Duo 08836973190Roche Diagnostics GmbH · Test, HIV detection105 reports
- ARCHITECT 2P36-01Abbott GmbH · Test, hiv detection1 recall0 reports
- cobas® HIV-1 09040803190Roche Molecular Systems, Inc. · Test, HIV detection27 reports
- Alere Determine™ HIV–1/2 Ag/Ab Combo 7D2649Alere Scarborough, Inc. · Test, Hiv Detection27 reports
- VITROS 6842781Ortho Clinical Diagnostics · Test, hiv detection16 reports
- RealTime 6L18-90Abbott Molecular Inc. · Test, hiv detection12 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.