Alinity 08P0721Recalls & reported problems
Abbott GmbH · Alinity i HIV Ag/Ab Combo Reagent Kit 200 Tests · Class 2
All models of Alinity (37)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00380740121754), received between Apr 25, 2023 and Sep 10, 2025 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “False Negative Result” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- False Negative Result1
- False Positive Result1
Patient problems
- Insufficient Information1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjurySep 10, 2025False Positive Result; False Positive Result
THE CUSTOMER REPORTED FALSE REACTIVE ALINITY I HIV AG/AB COMBO RESULTS WERE GENERATED FOR A 64-YEAR-OLD MALE PATIENT WHO WAS IN SURGERY READY AND WAITING TO RECEIVE A HEART TRANSPLANT. THE PATIENT DID NOT RECEIVE THE HEART TRANSPLANT DUE TO THEIR REACTIVE HIV RESULTS. THE PATIENT REMAINED ADMITTED IN THE HOSPITAL AND LATER RECEIVED ANOTHER DONATED HEART APPROXIMATELY 2 DAYS LATER.
Patient problems: Insufficient Information
MAUDE report 23017089 ↗MalfunctionApr 25, 2023False Negative Result; False Negative Result
THE CUSTOMER OBSERVED A FALSE NONREACTIVE ALINITY I HIV AG/AB COMBO RESULT FOR ONE PATIENT. THE ALINITY I HIV AG/AB COMBO RESULT WAS NONREACTIVE FOR SID (B)(6), AND A VIRAL LOAD WAS ALSO ORDERED. THE VIRAL LOAD RESULT WAS ¿DETECTED, 60000 COPIES/ML¿. THE DOCTOR THEN ASKED TO RETEST THE HIV SAMPLE ON THE ALINITY AND THE RETEST RESULT WAS ALSO NONREACTIVE. THE PATIENT HAD ANOTHER SPECIMEN COLLECTED 2 DAYS LATER AND RESULTED 7.55 S/CO. NO IMPACT TO PATIENT MANAGEMENT WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16809679 ↗
FDA clearance and classification
The device record lists FDA submission BP090080; its details are not in the openFDA clearance files we use.
The FDA regulates product code MZF (test, hiv detection) under 21 CFR 866.3956 as a Class II device. 21 CFR 866.3956 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Alinity 08P0721
Has the Alinity 08P0721 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00380740121754), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Alinity 08P0721?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between Apr 25, 2023 and Sep 10, 2025. In those reports, the most common specific device problems are “False Negative Result” (1) and “False Positive Result” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Alinity 08P0721?
None of the reports are classified as deaths, 1 as an injury and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the Alinity 08P0721, and is it still sold?
The FDA's device database lists Abbott GmbH as the company responsible for it (brand Alinity, model 08P0721). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Test, HIV detection devices
- Determine™ HIV–1/2 Ag/Ab Combo 7D2648Alere Scarborough, Inc. · Test, Hiv Detection405 reports
- Alere Determine™ HIV–1/2 Ag/Ab Combo 7D2648Alere Scarborough, Inc. · Test, Hiv Detection238 reports
- Elecsys HIV Duo 08836973190Roche Diagnostics GmbH · Test, HIV detection103 reports
- ARCHITECT 2P36-01Abbott GmbH · Test, hiv detection1 recall0 reports
- Alere Determine™ HIV–1/2 Ag/Ab Combo 7D2649Alere Scarborough, Inc. · Test, Hiv Detection27 reports
- cobas® HIV-1 09040803190Roche Molecular Systems, Inc. · Test, HIV detection24 reports
- VITROS 6842781Ortho Clinical Diagnostics · Test, hiv detection16 reports
- RealTime 6L18-90Abbott Molecular Inc. · Test, hiv detection12 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page