Alinity 08P0420Recalls & reported problems
Abbott GmbH · Alinity c Microalbumin Reagent Kit 640 Tests · Class 1
All models of Alinity (37)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00380740135201), received between May 3, 2023 and May 3, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Low Test Results” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Low Test Results1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 3, 2023Low Test Results; Low Test Results
THE CUSTOMER REPORTED THAT THE MICROALBUMIN COLLEGE OF AMERICAN PATHOLOGISTS (CAP) SURVEY FAILED ON THE ALINITY C PROCESSING MODULE (B)(6), AS ALL RESULTS ON THE 5 MICROALBUMIN CAP CHALLENGE WERE FALSELY DEPRESSED AND OFF BY 1 DECIMAL PLACE. IT WAS DETERMINED THAT WHEN THE INSTRUMENT WAS FIRST INSTALLED, MG/L WAS USED FOR ALINITY C MICROALBUMIN AND AT SOME POINT IN TIME THE UNIT OF MEASURE CONFIGURATION WAS CHANGED TO MG/DL. THE CUSTOMER COMMUNICATED THAT ABBOTT ASSISTED THE CUSTOMER WITH THIS CONFIGURATION STEP. UPON FURTHER REVIEW, THE ACTUAL UNITS WERE CHANGED FOR THE ASSAY, BUT NOT FOR THE CALIBRATOR. THE CONFIGURATION VALUES WERE ALL UPDATED TO BE SYNCHRONOUS WITH THE MG/DL UNIT OF MEASURE FROM THE MG/L UNIT OF MEASURE. A DATA PULL OF ALL MICROALBUMIN SAMPLES REPORTED SINCE THE ASSAY WENT LIVE IN JANUARY 2023 WAS COMPLETED WITH A TOTAL OF 591 PATIENT SAMPLES. INITIAL REVIEW OF THE DATA DOES NOT INCLUDE DATA FROM JANUARY TO (B)(6) 2023 NOR DOES IT INCLUDE OBJECTIVE VALUES. CUSTOMER NORMAL RANGE UALB IS 0.5-29 MG/DL. THE CORRECTED RESULTS FROM THE REVIEWED DATA IS AS FOLLOWS. IN REVIEWING THE DATA: ABNORMAL TO NORMAL = 110 SPECIMENS, ABNORMAL TO ABNORMAL = 30 SPECIMENS, LESS THA
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16863273 ↗
FDA clearance and classification
The FDA regulates product code JIQ (turbidimetric method, protein or albumin (urinary, non-quant.)) under 21 CFR 862.1645 as a Class I device. 21 CFR 862.1645 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Alinity 08P0420
Has the Alinity 08P0420 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00380740135201), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Alinity 08P0420?
The FDA's MAUDE database lists 1 adverse event report for this device, received on May 3, 2023. That report lists device problem “Low Test Results” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Alinity 08P0420?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Alinity 08P0420 FDA approved?
Devices of this type (product code JIQ) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Abbott GmbH.
Who makes the Alinity 08P0420, and is it still sold?
The FDA's device database lists Abbott GmbH as the company responsible for it (brand Alinity, model 08P0420). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other TURBIDIMETRIC METHOD, PROTEIN OR ALBUMIN (URINARY, NON-QUANT.) devices
- Alinity 08P0424Abbott Ireland · TURBIDIMETRIC METHOD, PROTEIN OR ALBUMIN (URINARY, NON-QUANT.)1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page