AlinIQ 03R89-24Recalls & reported problems
Abbott Srl · AlinIQ AMS · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00380740145125), received between Oct 31, 2022 and Feb 3, 2025 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Computer Software Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Computer Software Problem1
- Data Problem1
- Leak/Splash1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Exposure to Body Fluids1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 3, 2025Data Problem; Data Problem
THE CUSTOMER OBSERVED A RESULT MISMATCH FOR TWO PATIENT SAMPLES BY THE ALINITY CI-SERIES SYSTEM CONTROL MODULE AND THE ALINIQ AMS SOFTWARE. THE CUSTOMER REPORTED THAT AN INCORRECT MICROALBUMIN RESULT FOR SID: (B)(6) WAS RELEASED BY THE ALINITY CI-SERIES SYSTEM CONTROL MODULE INTO THE ALINIQ AMS SOFTWARE FOR A PATIENT. ON (B)(6) 2025, SID: (B)(6) GENERATED A MICROALBUMIN RESULT OF <5.0 MG/L, WHICH WAS RELEASED INTO THE ALINIQ AMS SOFTWARE. THE NEXT SAMPLE, SAMPLE ID: (B)(6), GENERATED A MICROALBUMIN RESULT OF 28.5 MG/L, WHICH WAS RELEASED INTO THE ALINIQ AMS SOFTWARE UNDER SID: (B)(6). CONSEQUENTLY, THE MICROALBUMIN RESULT FOR SID: (B)(6) WAS REPORTED OUT OF THE LAB AS 28.5 MG/L (INCORRECT RESULT) INSTEAD OF <5.0 MG/L (CORRECT RESULT). THE CUSTOMER HAS SINCE AMENDED THE PATIENT REPORT. THE ABBOTT SERVICE TEAM WAS UNABLE TO DETERMINE IF THE ISSUE WAS CAUSED BY THE ALINIQ AMS SOFTWARE OR THE ALINITY CI-SERIES SYSTEM CONTROL MODULE, SO THIS INCIDENT WILL BE REPORTED UNDER BOTH PRODUCTS. THERE WAS NO IMPACT TO PATIENT MANAGEMENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21294803 ↗MalfunctionFeb 20, 2024Computer Software Problem; Computer Software Problem
THE CUSTOMER OBSERVED MISMATCHED RESULTS THAT WERE AUTOMATICALLY VALIDATED ON ALINIQ SOFTWARE VERSION V2.10. THERE WAS A REVERSAL OF RESULTS BETWEEN THE PSA, TOTAL AND PSA, FREE ASSAY. A QPL RESULT OF 1.003 FOR PSA, TOTAL WAS AUTOMATICALLY VALIDATED EVEN THOUGH IT DID NOT CORRESPOND TO ANY RESULTS OUTPUT FROM THE MACHINE. IT WAS DETERMINED THAT THERE WAS AN ERROR IN THE CONFIGURATION RULES THAT WAS IMMEDIATELY IDENTIFIED BY AN ABBOTT EMPLOYEE AND CORRECTED. NO IMPACT TO PATIENT MANAGEMENT WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18737902 ↗MalfunctionOct 31, 2022Leak/Splash; Leak/Splash
THE CUSTOMER OBSERVED AFTER SAMPLES WERE LOADED ON THE ALINITY I PROCESSING MODULE, A REQUEST WAS DENIED. THE TECHNICIAN WAS ON SITE TO TROUBLESHOOT THE AMS CONNECTION. WHILE THE TECHNICIAN WAS ASSISTING THE REMOVAL OF THE SPECIMEN FROM THE ALINITY I TO BE PLACED ON THE COUNTER, THE SPECIMEN TUBE SLIPPED OUT OF THEIR HAND. IT WAS REPORTED THE SERUM SPRINKLED ON THEIR ARM. THE TECHNICIAN WAS WEARING GLOVES AND A MASK AT THE TIME OF THE EVENT. WHILE THE TECHNICIAN WAS RINSING AND DISINFECTING THEIR ARM, THE UNCLOTTED WOUND ON THEIR HAND WAS EXPOSED. THE SAMPLE WAS TESTED USING THE PREOPERATIVE 8-ASSAY PANEL. THE RESULTS WERE: HEPATITIS B FIVE-ASSAY PANEL WAS POSITIVE FOR 1, 3, AND 5 [HBSAG, HBEAG, AND HBCAB], AND NEGATIVE FOR AIDS, HEPATITIS C, AND SYPHILIS. THE TECHNICIAN HAD BLOOD DRAWN AND WAS TESTED USING THE PREOPERATIVE 8-ASSAY PANEL AT THE LABORATORY. THE HEPATITIS B FIVE-ASSAY PANEL WAS POSITIVE FOR 2 AND 5 [HBSAB AND HBCAB], AND NEGATIVE FOR AIDS, HEPATITIS C, AND SYPHILIS. NO ADDITIONAL INFORMATION WAS PROVIDED AT THIS TIME. ADDITIONALLY, IT WAS REPORTED THAT THE AMS COMMUNICATION WAS NORMAL; HOWEVER, LIS DID NOT SEND THE REQUEST TO AMS. THIS RETURNED TO NORMAL AFTER CONTAC
Patient problems: Exposure to Body Fluids
MAUDE report 15698098 ↗
Other Calculator/data processing module, for clinical use devices
- BD Synapsys™ Informatics Solution 444150Becton, Dickinson And Company · Calculator/data processing module, for clinical use5 recalls81 reports
- cobas® infinity central lab 07154003001Roche Diagnostics GmbH · Calculator/data processing module, for clinical use2 recalls31 reports
- BD EpiCenter™ Data Management System 441007Becton, Dickinson And Company · CALCULATOR/DATA PROCESSING MODULE, FOR CLINICAL USE1 recall21 reports
- Expanse Laboratory/Genetics/Microbiology/Anatomical PathologyMedical Information Technology, Inc. · Calculator/Data Processing Module, For Clinical Use1 recall2 reports
- Kaluza C Perpetual LicenseBeckman Coulter, Inc. · Calculator/Data Processing Module, For Clinical Use1 recall0 reports
- Kaluza C 10 User NetworkBeckman Coulter, Inc. · Calculator/Data Processing Module, For Clinical Use1 recall0 reports
- REMISOL Advance 2.4Beckman Coulter, Inc. · Calculator/Data Processing Module, For Clinical Use1 recall0 reports
- BD EpiCenter™ Data Management System 440981Becton, Dickinson And Company · Calculator/data processing module, for clinical use1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page