BD Nexiva™ Closed IV Catheter System 383641Recalls & reported problems

Becton, Dickinson And Company · BD Nexiva™ Closed IV Catheter System 24GA x 0.75IN · Class 2

All models of BD Nexiva Closed IV Catheter System (7)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00382903836413), received between Dec 5, 2024 and May 6, 2026 — classified as 7 malfunctions.

The most frequently reported specific device problem is “Leak/Splash” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 2 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Leak/Splash4
  • Fluid/Blood Leak2
  • Difficult or Delayed Separation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions7

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 6, 2026Fluid/Blood Leak

    DURING USE, THE END CAP DOES NOT SEAL PROPERLY WITH THE CANNULA BODY, CAUSING BLOOD TO LEAK. THERE ARE 10 DEFECTIVE UNITS. TWO DEFECTIVE PRODUCTS CAN BE RETURNED, AND PHOTOGRAPHS ARE AVAILABLE. WE REQUIRE A CLAIM SETTLEMENT, A RESPONSE TO THE COMPLAINT, AND A RECEIPT OF THE COMPLAINT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25104162 ↗
  • MalfunctionApr 16, 2026Fluid/Blood Leak

    DURING USE OF THIS PRODUCT, IT WAS DISCOVERED THAT THE PINCH CLAMP WAS DAMAGED AND FAILED TO SECURE THE TUBING PROPERLY, RESULTING IN BLOOD LEAKAGE; TWO UNITS WERE AFFECTED; PHYSICAL DEVICES CANNOT BE RETURNED, BUT PHOTOGRAPHS ARE AVAILABLE; A GREEN CLAIM IS REQUIRED, ALONG WITH A RESPONSE LETTER TO THE COMPLAINT AND A COMPLAINT ACKNOWLEDGMENT LETTER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24898994 ↗
  • MalfunctionFeb 17, 2026Leak/Splash

    DURING USE, LEAKAGE OCCURRED AT THE CATHETER CONNECTION POINT. TWO DEFECTIVE UNITS WERE IDENTIFIED. ONE DEFECTIVE UNIT MAY BE RETURNED, WITH PHOTOGRAPHIC EVIDENCE PROVIDED. A CLAIM IS REQUIRED, ALONG WITH A COMPLAINT RESPONSE LETTER AND A COMPLAINT RECEIPT CONFIRMATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24366908 ↗
  • MalfunctionSep 12, 2025Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT BD NEXIVA 24GA 0.75IN Y W/ CAP. LEAKAGE. WE HAVE RECEIVED A COMPLAINT FROM OUR DEPARTMENT REGARDING THIS PRODUCT, SPECIFICALLY LOT NUMBER 5085401. DURING USE, IT WAS OBSERVED THAT THE PRODUCT LEAKS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23036890 ↗
  • MalfunctionAug 5, 2025Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT BD NEXIVA 24GA 0.75IN Y W/ CAP LEAKED, THE NEXIVA PRODUCT IS LEAKING WATER AT THE QSITE TIP.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22716990 ↗
  • MalfunctionDec 8, 2024Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT BD NEXIVA W/ CAP LEAKED. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER, TRANSLATED FROM DUTCH TO ENGLISH: LEAKAGE AT SPLIT NEEDLE HOSE. 27 NOV WAS THE DEVICE BEING USED IN/ON PATIENT WHEN THE ISSUE OCCURRED? YES. WAS PATIENT OR USER HARMED? IF YES, PLEASE EXPLAIN NO. WAS THE HCP PRESENT WHEN THE ISSUE OCCURRED? YES. IF LEAKAGE OCCURRED, PLEASE CONFIRM THE FLUID THAT LEAKED. NACL 0.9%. WAS ADDITIONAL MEDICAL INTERVENTION/MEDICATION REQUIRED? IF YES, PLEASE EXPLAIN. NO.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20874769 ↗
  • MalfunctionDec 5, 2024Difficult or Delayed Separation; Difficult or Delayed Separation

    NO ADDITIONAL INFORMATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20858777 ↗

Other Catheter, intravascular, therapeutic, short-term less than 30 days devices