BD Phoenix™ NID 448007Recalls & reported problems
Becton, Dickinson And Company · BD Phoenix™ NID · Class 1
Data updated Nov 27, 2026 from official FDA records · Editorial policy
Quick summary
This BD Phoenix NID panel, used to identify gram-negative bacteria, has 133 reports, most describing incorrect, inadequate or imprecise results. The reports mention 1 injury and no deaths, and no recalls name this device. Reports rose to 42 in the last 12 months from 16 in the previous 12.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 134
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 134 adverse event reports that list this exact device (DI 00382904480073), received between Mar 27, 2021 and Sep 29, 2026 — classified as 1 injury, 133 malfunctions.
The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (131 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Incorrect, Inadequate or Imprecise Result or Readings131
- False Positive Result2
- Incorrect Measurement1
Patient problems
- No Clinical Signs, Symptoms or Conditions134
Recent adverse event reports
The 25 most recent of 134 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 29, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50941221 ↗MalfunctionSep 29, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50938975 ↗MalfunctionSep 17, 2026Incorrect, Inadequate or Imprecise Result or Readings
It was reported while using the BD Phoenix¿ NID a patient isolate (Escherichia coli) was misidentified as Pantoae agglomerans. The user verified the final result using MALDI. No health impact or consequence reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50809420 ↗MalfunctionSep 15, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50776507 ↗MalfunctionSep 15, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50776502 ↗MalfunctionSep 15, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50773772 ↗MalfunctionAug 28, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50503524 ↗MalfunctionAug 28, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50497115 ↗MalfunctionAug 26, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50460946 ↗MalfunctionAug 26, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50456696 ↗MalfunctionAug 24, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50408867 ↗MalfunctionAug 21, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50379905 ↗MalfunctionAug 21, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50379899 ↗MalfunctionAug 12, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50220930 ↗MalfunctionAug 11, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50214126 ↗MalfunctionAug 11, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50213121 ↗MalfunctionAug 11, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50207425 ↗MalfunctionJul 30, 2026Incorrect, Inadequate or Imprecise Result or Readings
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50084464 ↗MalfunctionMay 27, 2026Incorrect, Inadequate or Imprecise Result or Readings
IT WAS REPORTED WHILE USING THE BD PHOENIX¿ NID A PATIENT URINE ISOLATE (ESCHERICHIA COLI) WAS MISIDENTIFIED AS PASTEURELLA AEROGENES. THE USER VERIFIED THE FINAL RESULT USING MALDI. NO HEALTH IMPACT OR CONSEQUENCE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25300815 ↗MalfunctionMay 21, 2026Incorrect, Inadequate or Imprecise Result or Readings
IT WAS REPORTED WHILE USING THE BD PHOENIX¿ NID A PATIENT ISOLATE (ESCHERICHIA COLI) WAS MISIDENTIFIED AS CITROBACTER KOSERI AND CITROBACTER FARMERI WHEN REPEAT TESTING WAS PERFORMED WITH AN AFFILIATED LABORATORY. NO INFORMATION COULD BE PROVIDED ON PATIENT IMPACT, BUT THE USER STATED THAT THE COLONY MORPHOLOGY WAS SIMILAR TO ESCHERICHIA COLI. THIS IS REPORT 2 OF 2.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25242695 ↗MalfunctionMay 21, 2026Incorrect, Inadequate or Imprecise Result or Readings
IT WAS REPORTED WHILE USING THE BD PHOENIX¿ NID A PATIENT ISOLATE (ESCHERICHIA COLI) WAS MISIDENTIFIED AS CITROBACTER KOSERI AND CITROBACTER FARMERI WHEN REPEAT TESTING WAS PERFORMED WITH AN AFFILIATED LABORATORY. NO INFORMATION COULD BE PROVIDED ON PATIENT IMPACT, BUT THE USER STATED THAT THE COLONY MORPHOLOGY WAS SIMILAR TO ESCHERICHIA COLI.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25240705 ↗MalfunctionApr 30, 2026Incorrect, Inadequate or Imprecise Result or Readings
IT WAS REPORTED WHILE USING THE BD PHOENIX¿ NID A PATIENT ISOLATE (ACINETOBACTER BAUMANNII) WAS MISIDENTIFIED AS MORAXELLA (FORMERLY BRANHAMELLA) CATARRHALIS. THE USER VERIFIED THE FINAL RESULT USING BACTERIAL CULTURE. NO HEALTH IMPACT OR CONSEQUENCE REPORTED. THIS IS REPORT 16 OF 17.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25051159 ↗MalfunctionApr 30, 2026Incorrect, Inadequate or Imprecise Result or Readings
IT WAS REPORTED WHILE USING THE BD PHOENIX¿ NID A PATIENT ISOLATE (ACINETOBACTER BAUMANNII) WAS MISIDENTIFIED AS MORAXELLA (FORMERLY BRANHAMELLA) CATARRHALIS. THE USER VERIFIED THE FINAL RESULT USING BACTERIAL CULTURE. NO HEALTH IMPACT OR CONSEQUENCE REPORTED. THIS IS REPORT 17 OF 17.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25051145 ↗MalfunctionApr 30, 2026Incorrect, Inadequate or Imprecise Result or Readings
IT WAS REPORTED WHILE USING THE BD PHOENIX¿ NID A PATIENT ISOLATE (ACINETOBACTER BAUMANNII) WAS MISIDENTIFIED AS MORAXELLA (FORMERLY BRANHAMELLA) CATARRHALIS. THE USER VERIFIED THE FINAL RESULT USING BACTERIAL CULTURE. NO HEALTH IMPACT OR CONSEQUENCE REPORTED. THIS IS REPORT 14 OF 17.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25051137 ↗MalfunctionApr 30, 2026Incorrect, Inadequate or Imprecise Result or Readings
IT WAS REPORTED WHILE USING THE BD PHOENIX¿ NID A PATIENT ISOLATE (ACINETOBACTER BAUMANNII) WAS MISIDENTIFIED AS MORAXELLA (FORMERLY BRANHAMELLA) CATARRHALIS. THE USER VERIFIED THE FINAL RESULT USING BACTERIAL CULTURE. NO HEALTH IMPACT OR CONSEQUENCE REPORTED. THIS IS REPORT 15 OF 17.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25051136 ↗
FDA clearance and classification
The FDA regulates product code LQM (gram negative identification panel) under 21 CFR 866.2660 as a Class I device. 21 CFR 866.2660 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Common questions about the BD Phoenix™ NID 448007
Has the BD Phoenix™ NID 448007 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00382904480073), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the BD Phoenix™ NID 448007?
The FDA's MAUDE database lists 134 adverse event reports for this device, received between Mar 27, 2021 and Sep 29, 2026. In those reports, the most common specific device problems are “Incorrect, Inadequate or Imprecise Result or Readings” (131), “False Positive Result” (2) and “Incorrect Measurement” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the BD Phoenix™ NID 448007?
None of the reports are classified as deaths, 1 as an injury and 133 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the BD Phoenix™ NID 448007 FDA approved?
Devices of this type (product code LQM) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Becton, Dickinson And Company.
Who makes the BD Phoenix™ NID 448007, and is it still sold?
The FDA's device database lists Becton, Dickinson And Company as the company responsible for it (brand BD Phoenix™ NID, model 448007). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other GRAM NEGATIVE IDENTIFICATION PANEL devices
- VITEK® 2 GNBiomerieux , Inc. · Gram negative identification panel1 recall144 reports
- BD BBL™ Crystal™ E/NF 245000Becton, Dickinson And Company · GRAM NEGATIVE IDENTIFICATION PANEL1 report
- MicroScan B1017-411Beckman Coulter, Inc. · Gram Negative Identification Panel1 report
- MicroScan B1010-41ABeckman Coulter, Inc. · Gram Negative Identification Panel1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page