Gentrix® MSPL0507Recalls & reported problems
Acell, Inc. · Gentrix® Surgical Matrix Plus 5 x 7 cm · Class 2 · Implant
All models of Gentrix (13)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00386190001226), received between May 31, 2019 and Jan 2, 2020 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Insufficient Device Problem Information1
- Material Split, Cut or Torn1
Patient problems
- No Consequences Or Impact To Patient1
- No Known Impact Or Consequence To Patient1
- Obstruction/Occlusion1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJan 2, 2020Insufficient Device Problem Information; Insufficient Device Problem Information
ON 12/6/19, ACELL, INC. BECAME AWARE THAT AN ACELL DEVICE WAS EXPLANTED DUE TO A BOWEL OBSTRUCTION. THE ACELL DEVICE WAS IMPLANTED (B)(6) 2019 AND EXPLANTED ON (B)(6) 2019. WE ARE SUBMITTING THIS REPORT NOW, HOWEVER, ADDITIONAL INFORMATION HAS BEEN REQUESTED. AN UPDATE "WLLL" BE PROVIDED UPON RECIEPT OF MORE INFORMATION.
Patient problems: Obstruction/Occlusion
MAUDE report 9538229 ↗MalfunctionMay 31, 2019Material Split, Cut or Torn; Material Split, Cut or Torn
ON (B)(4) 2019, ACELL, INC. BECAME AWARE THAT SUTURE PULL THROUGH OCCURRED WITH AN ACELL DEVICE DURING THE REINFORCEMENT OF A UMBILICAL HERNIA REPAIR. THE DEVICE WAS NOT USED. THE SURGEON DECIDED TO CLOSE THE HERNIA PRIMARILY WHICH RESULTED IN A SURGICAL DELAY (INCREASED SURGERY TIME). THE PATIENT DID NOT EXPERIENCE ANY COMPLICATION DUE TO THE SUTURE PULL THROUGH NOR THE INCREASED SURGERY TIME.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 8659456 ↗
FDA clearance and classification
The FDA regulates product code FTM (mesh, surgical) under 21 CFR 878.3300 as a Class II device. 21 CFR 878.3300 ↗
Devices of this type normally need 510(k) clearance before sale.
Common questions about the Gentrix® MSPL0507
Has the Gentrix® MSPL0507 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00386190001226), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Gentrix® MSPL0507?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between May 31, 2019 and Jan 2, 2020. In those reports, the most common specific device problem is “Material Split, Cut or Torn” (1); the most common patient problem is “Obstruction/Occlusion” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Gentrix® MSPL0507?
None of the reports are classified as deaths, 1 as an injury and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Gentrix® MSPL0507 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Safe: it poses no known hazards in any MRI environment.
Who makes the Gentrix® MSPL0507, and is it still sold?
The FDA's device database lists Acell, Inc. as the company responsible for it (brand Gentrix®, model MSPL0507). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Mesh, surgical devices
- MEDPOR TITAN 81032Stryker Leibinger GmbH & Co. KG · Mesh, surgical1 recall1 report
- Peri-Guard PC1016NSynovis Life Technologies, Inc. · Mesh, surgical1 recall1 report
- SurgiMend® 606-400-009Tei Biosciences Inc. · Mesh, surgical1 recall0 reports
- Peri-Guard PC0814NSynovis Life Technologies, Inc. · Mesh, surgical1 recall0 reports
- SurgiMend® 606-300-008Tei Biosciences Inc. · Mesh, surgical1 recall0 reports
- SurgiMend® 606-001-008Tei Biosciences Inc. · Mesh, surgical1 recall0 reports
- SurgiMend® 606-001-006Tei Biosciences Inc. · Mesh, surgical1 recall0 reports
- SurgiMend® 606-300-022Tei Biosciences Inc. · Mesh, surgical1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page