Skip to content

N/A 8960-7Recalls & reported problems

Salter Labs · NebuTech® HDN® Nebulizer with inhalation and exhalation valve, universal mask adaptor, mouthpiece, 7’ (2.1 m) supply tube · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00607411890420), received between Oct 31, 2025 and Oct 31, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Loose or Intermittent Connection” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Loose or Intermittent Connection1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 31, 2025Loose or Intermittent Connection; Loose or Intermittent Connection

    IT WAS REPORTED: THE POP OFF VALVE HAD A LOOSE FIT AND DID NOT STAY IN PLACE WHEN IN USE DURING THE NEBULIZER TREATMENT. THERE WAS NO REPORTED INJURY. ADDITIONAL INFORMATION RECEIVED 21OCT2025 REPORTED, THE ISSUE WAS DISCOVERED DURING SETUP OF THE NEBULIZER, IMMEDIATELY PRIOR TO PLACING THE DEVICE ON THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23440705 ↗

Other NEBULIZER (DIRECT PATIENT INTERFACE) devices

All NEBULIZER (DIRECT PATIENT INTERFACE) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page