Ballard* Multi-Access Port Closed Suction System 10136Recalls & reported problems
Avanos Medical, Inc. · BALLARD* Multi-Access Port Catheter, Double Swivel Y, WET PAK* · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00609038101361), received between May 6, 2021 and May 6, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Disconnection” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Disconnection1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 6, 2021Disconnection; Disconnection
PER INFORMATION PROVIDED IN FDA USER FACILITY REPORT (B)(4) RECEIVED ON APR 14, 2021, "HALYARD MULTI-ACCESS PORT REPEATEDLY POPPED OFF WHEN CONNECTED TO RUSCH 2.5MM ENDOTRACHEAL TUBE (ET). HOSPITAL STAFF REPORT THAT THE MULTI-ACCESS CATHETER USED INDICATED THAT IT WAS APPROPRIATE FOR 2.5MM ENDOTRACHEAL TUBE ACCORDING TO PACKAGING. PATIENT WAS REINTUBATED USING A DIFFERENT ET TUBE (SHILEY 2.5MM) AND THE MULTI-ACTION CATHETER DID NOT POP OFF." "THE ORIGINAL INTENDED PROCEDURE WAS ADMINISTRATION OF MEDICATION INTO THE ET TUBE." NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11787664 ↗
Other CATHETERS, SUCTION, TRACHEOBRONCHIAL devices
- Ballard* Closed Suction System 93826Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall70 reports
- Ballard* Closed Suction System 92431Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL78 reports
- Medline DYNCPDS14Medline Industries, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall16 reports
- Ballard* Turbo-Cleaning Closed Suction System 98965Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall16 reports
- Ballard* Turbo-Cleaning Closed Suction System 98263Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall11 reports
- Ballard* Closed Suction System for Adults 98310Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall1 death9 reports
- Medline DYNCPTP14TMedline Industries, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall6 reports
- Medline DYNCPTP14Medline Industries, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall4 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page