Ballard* Closed Suction System 93825Recalls & reported problems
Avanos Medical, Inc. · BALLARD* Closed Suction Catheter, Y-Adapter, Neonatal/Pediatric · Class 1
All models of Ballard* Closed Suction System (30)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00609038938257), received between Feb 3, 2022 and Apr 3, 2026 — classified as 1 injury, 5 malfunctions.
The most frequently reported specific device problem is “Break” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Break4
- Material Integrity Problem1
- Suction Failure1
Patient problems
- Decreased Peak Expiratory Flow rate2
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Bacterial Infection1
- Foreign Body In Patient1
- Low Oxygen Saturation1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 3, 2026Break
IT WAS REPORTED THAT THE PATIENT HAD JUST COMPLETED CARE, AND THE MOTHER REQUESTED TO HOLD THE INFANT. THE RT AND NURSE PREPARED TO TRANSFER THE PATIENT WITH THE MOTHER TO A CHAIR. DURING THE PREPARATION, THE RT NOTED A LEAK; THE MOTHER AND GRANDMOTHER STATED THEY HAD HEARD A SIMILAR SOUND ON PREVIOUS DAYS, BUT THAT NO ISSUE HAD BEEN IDENTIFIED. THE PATIENT WAS TRANSFERRED SAFELY WITH THE MOTHER TO THE CHAIR, AT WHICH TIME THE LEAK BECAME LOUDER. AFTER SECURING THE PATIENT AND VENTILATOR TUBING TO THE MOTHER AND CHAIR, THE RT IDENTIFIED THAT THE Y CONNECTOR CONNECTING THE VENTILATOR TUBING AND SUCTION BALLARD TO THE ETT WAS COMPLETELY BROKEN, WITH A PORTION LODGED IN THE PROXIMAL END OF THE ETT. THE PATIENT REMAINED STABLE THROUGHOUT THE EVENT. THE RT MANUALLY STABILIZED THE BROKEN COMPONENTS AND NOTIFIED THE PRACTITIONER, WHO ARRIVED PROMPTLY. THE RT SECURELY HELD THE ETT WHILE THE PRACTITIONER USED MEDICAL FORCEPS TO SAFELY REMOVE THE BROKEN PIECE. THE PATIENT TOLERATED THE PROCEDURE WELL AND REMAINED STABLE THROUGHOUT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24779338 ↗InjuryFeb 14, 2023Material Integrity Problem; Material Integrity Problem
ADDITIONAL INFORMATION RECEIVED 19JAN2023 REPORTED, MID-SHIFT ON (B)(6) 2023, THE REGISTERED NURSE (RN) FOUND THE PLASTIC SLEEVE TO THE CLOSED SUCTION CATHETER (CSC) ¿OPEN NEARLY END TO END¿. THEY WERE UNSURE IF IT HAD BEEN THAT WAY BEFORE AS THE TEAR WAS ONLY VISIBLE ON ONE SIDE; THE PATIENT HAD BEEN SUCTIONED AT LEAST HOURLY FOR MOST OF THE DAY; THE CSC HAD BEEN IN USE FOR POSSIBLY 5 DAYS. THE PATIENT WAS EVALUATED FOR SEPSIS, A TRACH ASPIRATE (TA) WAS PERFORMED AND FOUND TO HAVE GRAM POSITIVE COCCI FOR WHICH THE INFANT WAS STARTED ON ANTIBIOTICS. A CHEST X-RAY (CXR) REVEALED AREAS OF ATELECTASIS THAT MAY OR MAY NOT HAVE BEEN ASSOCIATED WITH A PNEUMONIA; A PERIPHERAL BLOOD CULTURE WAS POSITIVE FOR ENTEROCOCCUS FECALIS, (CONSIDERED AN ABSOLUTE PATHOGEN); ARTERIAL BLOOD WAS NEGATIVE FOR ANY MICROBES. IT WAS ADDITIONALLY REPORTED, THERE WAS NO WAY TO DEFINITIVELY ASSOCIATE POTENTIAL CENTRAL LINE-ASSOCIATED BLOODSTREAM INFECTION (CLABSI) WITH (TA) EXCEPT SAME GRAMS STAINED DESCRIPTION FOR ORGANISM. ADDITIONAL INFORMATION RECEIVED 06FEB2023 CLARIFIED, THE TA WAS NEGATIVE, PERFORMED ON (B)(6) 2023; THE BLOOD CULTURE WAS POSITIVE.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Bacterial Infection
MAUDE report 16375824 ↗MalfunctionJan 31, 2023Break; Break
AVANOS MEDICAL RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING TWO DIFFERENT EVENTS. THIS IS THE SECOND OF TWO REPORTS. REFER TO 8030647-2023-00011 FOR THE FIRST EVENT. IT WAS REPORTED "A BREAK IN THE PLASTIC SHEATH COVERING [THE] INLINE BALLARD SUCTION CATHETER RESULT[ED] IN LOSS OF VENTILATOR PRESSURE TO THE INFANT." THERE WAS NO REPORTED INJURY. ADDITIONAL INFORMATION RECEIVED 11-JAN-2023 STATED THE CLOSED SUCTION CATHETER (CSC) WAS IN USE "LESS THAN 3 DAYS" PRIOR TO THE REPORTED INCIDENT OCCURRING.
Patient problems: Decreased Peak Expiratory Flow rate
MAUDE report 16274672 ↗MalfunctionJan 31, 2023Break; Break
AVANOS MEDICAL RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING TWO DIFFERENT EVENTS. THIS IS THE FIRST OF TWO REPORTS. REFER TO 8030647-2023-00012 FOR THE SECOND EVENT. IT WAS REPORTED "A BREAK IN THE PLASTIC SHEATH COVERING [THE] INLINE BALLARD SUCTION CATHETER RESULT[ED] IN LOSS OF VENTILATOR PRESSURE TO THE INFANT." THERE WAS NO REPORTED INJURY. ADDITIONAL INFORMATION RECEIVED 11-JAN-2023 STATED THE CLOSED SUCTION CATHETER (CSC) WAS NOT ALTERED IN ANYWAY PRIOR TO THE REPORTED INCIDENT OCCURRING.
Patient problems: Decreased Peak Expiratory Flow rate
MAUDE report 16274666 ↗MalfunctionJun 20, 2022Break; Break
IT WAS REPORTED, THE INFANT IN THE NEONATAL INTENSIVE CARE UNIT (NICU) WAS INTUBATED WITH THE 7FR IN-LINE SUCTION CATHETER, PART OF THE ADAPTER FOR THE SUCTION BROKE OFF AND BECAME STUCK IN THE INFANT¿S ENDOTRACHEAL TUBE; IT WAS REMOVED WITH A HEMOSTAT CLAMP. THERE WAS NO REPORTED INJURY. ADDITIONAL INFORMATION RECEIVED 02JUN2022 REPORTED THAT THE CATHETER WAS IN PLACE BETWEEN 12-24 HOURS [PRIOR TO THE EVENT]. THERE WAS NO REPORTED INJURY.
Patient problems: Foreign Body In Patient
MAUDE report 14749402 ↗MalfunctionFeb 3, 2022Suction Failure; Suction Failure
IT WAS REPORTED THE CLOSED SUCTION CATHETER WAS NOTED TO BE LEAKING AIR WHEN SUCTIONING. THE PATIENT EXPERIENCED DECREASED OXYGENATION AND HEART RATE LEADING TO FURTHER UNSPECIFIED MEDICAL INTERVENTIONS.
Patient problems: Low Oxygen Saturation
MAUDE report 13446415 ↗
FDA clearance and classification
The FDA regulates product code BSY (catheters, suction, tracheobronchial) under 21 CFR 868.6810 as a Class I device. 21 CFR 868.6810 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Ballard* Closed Suction System 93825
Has the Ballard* Closed Suction System 93825 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00609038938257), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Ballard* Closed Suction System 93825?
The FDA's MAUDE database lists 6 adverse event reports for this device, received between Feb 3, 2022 and Apr 3, 2026. In those reports, the most common specific device problems are “Break” (4), “Material Integrity Problem” (1) and “Suction Failure” (1); the most common patient problems are “Decreased Peak Expiratory Flow rate” (2), “Bacterial Infection” (1) and “Foreign Body In Patient” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Ballard* Closed Suction System 93825?
None of the reports are classified as deaths, 1 as an injury and 5 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Ballard* Closed Suction System 93825 FDA approved?
Devices of this type (product code BSY) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Avanos Medical, Inc.
Who makes the Ballard* Closed Suction System 93825, and is it still sold?
The FDA's device database lists Avanos Medical, Inc. as the company responsible for it (brand Ballard* Closed Suction System, model 93825). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other CATHETERS, SUCTION, TRACHEOBRONCHIAL devices
- Ballard* Closed Suction System 93826Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall70 reports
- Ballard* Closed Suction System 92431Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL78 reports
- Ballard* Turbo-Cleaning Closed Suction System 98965Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall15 reports
- Medline DYNCPDS14Medline Industries, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall15 reports
- Ballard* Turbo-Cleaning Closed Suction System 98263Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall11 reports
- Ballard* Closed Suction System for Adults 98310Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall1 death9 reports
- Medline DYNCPTP14TMedline Industries, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall5 reports
- Medline DYNCPTP14Medline Industries, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall4 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page