Ballard* Closed Suction System for Adults 98312Recalls & reported problems

Avanos Medical, Inc. · BALLARD* Closed Suction Catheter, Double Swivel Elbow, WET PAK* · Class 1

All models of Ballard* Closed Suction System for Adults (17)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00609038983127), received between Jun 19, 2023 and Jan 30, 2025 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Suction Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Suction Problem2
  • Break1
  • Decoupling1
  • Decrease in Suction1

Patient problems

  • Insufficient Information2
  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 30, 2025Decrease in Suction; Suction Problem; Decrease in Suction; Suction Problem

    IT WAS REPORTED, THE CONDENSATION WAS INCREASED IN THE AIRWAY CIRCUIT PROBE, WITH LOW SUCTION FORCE THE CLOSED SUCTION SYSTEM DID NOT ACHIEVE ADEQUATE BRONCHIAL SWEEP AND REQUIRED MORE THAN 10 ASPIRATIONS TO MOBILIZE SECRETIONS. THE DEVICE WAS REPORTED TO HAVE BEEN IN PLACE FOR LESS THAN 20 HOURS. THERE WAS NO REPORTED INJURY.

    Patient problems: Insufficient Information

    MAUDE report 21277146 ↗
  • MalfunctionOct 15, 2024Break; Break

    IT WAS REPORTED, THE ENDOTRACHEAL TUBE (ETT) BROKE AT THE INLET OF THE PROBE WHICH CAUSED A CIRCUIT LEAK DURING PATIENT USE (THE DEVICE HAD BEEN IN USE FOR LESS THAN 20 HOURS); THERE WAS NO REPORTED INJURY. ADDITIONAL INFORMATION RECEIVED 18SEP2024 REPORTED, THE PATIENT DID NOT PRESENT ANY COMPLICATION ABOUT THE USE OF THE MEDICAL DEVICE, BUT APPROXIMATELY 10 DAYS AFTER THE INCIDENT THE PATIENT DIED FROM A SEVERE ABDOMINAL SEPSIS. NO ADDITIONAL INFORMATION WAS PROVIDED CONCERNING THE PATIENT OR IF THEY HAD ANY EXISTING MEDICAL CONDITION(S).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20450510 ↗
  • MalfunctionFeb 12, 2024Decoupling; Decoupling

    IT WAS REPORTED, THE RESPIRATORY THERAPIST PERFORMED A ROUTINE CHANGE OF THE CLOSED SUCTION SYSTEM ON A TRACHEOSTOMIZED PATIENT, AT THE MOMENT OF CONNECTING THE VIAL FOR INSTILLATION IN ITS CORRESPONDING PORT, IT DETACHED AND UNCOUPLED UNTIL THE INTERNAL SPRING WAS OBSERVED. IT WAS IMMEDIATELY CHANGED, ¿THERE WAS NO DAMAGE OR CLINICAL OR HEMODYNAMIC ALTERATION TO THE PATIENT." THE DEVICE WAS REPORTEDLY IN PLACE FOR LESS THAN 20 HOURS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18687824 ↗
  • MalfunctionJun 19, 2023Suction Problem; Suction Problem

    ADDITIONAL INFORMATION NOTED SUCTION FAILURE OCCURRED DURING INITIAL SET-UP USE AND WAS REPLACED IMMEDIATELY.

    Patient problems: Insufficient Information

    MAUDE report 17159520 ↗