Ballard* Closed Suction System 98388Recalls & reported problems
Avanos Medical, Inc. · BALLARD* Closed Suction Catheter, Elbow, Neonatal/Pediatric · Class 1
All models of Ballard* Closed Suction System (30)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00609038983882), received between Oct 24, 2024 and Oct 24, 2024 — classified as 2 injuries.
The most frequently reported specific device problem is “Gas/Air Leak” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Gas/Air Leak2
Patient problems
- Low Oxygen Saturation2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryOct 24, 2024Gas/Air Leak; Gas/Air Leak
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING THE SAME PATIENT. THIS IS THE SECOND OF TWO REPORTS. REFER TO 8030647-2024-00076 FOR THE FIRST REPORT. A MEMBER OF THE NURSING TEAM REPORTED, DURING THE NIGHT SHIFT, A ROUTINE CLOSE SUCTION CHANGE [WAS] UNDERTAKEN USING BALLARD CLOSED SUCTION (ELBOW) SIZE 6FR FOR THE FIRST TIME AND THE BABY¿S TRANSCUTANEOUS PARTIAL PRESSURE OF CO2 (TCPCO2) INCREASED CONSIDERABLY WITH EPISODES OF DESATURATION AND REQUIRED INCREASED OXYGEN. DURING [THE] DAY SHIFT A NEW BALLARD CLOSED SUCTION (ELBOW) SIZE 6FR WAS TRAILED AGAIN ON THE SAME BABY, AND IT WAS NOTED A SUDDEN DRASTIC INCREASE [OF] TCPCO2 AND DESATURATION; [THE] BABY [AGAIN] REQUIRED AN INCREASE IN OXYGEN. THE DECISION WAS MADE TO DO A CAPILLARY BLOOD GAS WHICH SHOWED A CORRELATION IN THE INCREASE OF THE PC02 [THE] BABY REQUIRED AND INCREASE IN VENTILATION PRESSURES. ON REVIEW OF [THE] BLOOD GAS THE BALLARD CLOSED SUCTION (ELBOW) SIZE 6FR WAS REMOVED AND A AN 8 FR BALLARD CLOSED SUCTION (Y-ADAPTER) WAS ATTACHED; [THE] BABY¿S TCPCO2 READING STABILIZED, AND A BLOOD GAS WAS REPEATED WHICH REFLECTED THE IMPR
Patient problems: Low Oxygen Saturation
MAUDE report 20529695 ↗InjuryOct 24, 2024Gas/Air Leak; Gas/Air Leak
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING THE SAME PATIENT. THIS IS THE FIRST OF TWO REPORTS. REFER TO 8030647-2024-00077 FOR THE SECOND REPORT. A MEMBER OF THE NURSING TEAM REPORTED, DURING THE NIGHT SHIFT, A ROUTINE CLOSE SUCTION CHANGE [WAS] UNDERTAKEN USING BALLARD CLOSED SUCTION (ELBOW) SIZE 6FR FOR THE FIRST TIME AND THE BABY¿S TRANSCUTANEOUS PARTIAL PRESSURE OF CO2 (TCPCO2) INCREASED CONSIDERABLY WITH EPISODES OF DESATURATION AND REQUIRED INCREASED OXYGEN. DURING [THE] DAY SHIFT A NEW BALLARD CLOSED SUCTION (ELBOW) SIZE 6FR WAS TRAILED AGAIN ON THE SAME BABY, AND IT WAS NOTED A SUDDEN DRASTIC INCREASE [OF] TCPCO2 AND DESATURATION; [THE] BABY [AGAIN] REQUIRED AN INCREASE IN OXYGEN. THE DECISION WAS MADE TO DO A CAPILLARY BLOOD GAS WHICH SHOWED A CORRELATION IN THE INCREASE OF THE PC02 [THE] BABY REQUIRED AND INCREASE IN VENTILATION PRESSURES. ON REVIEW OF [THE] BLOOD GAS THE BALLARD CLOSED SUCTION (ELBOW) SIZE 6FR WAS REMOVED AND A AN 8 FR BALLARD CLOSED SUCTION (Y-ADAPTER) WAS ATTACHED; [THE] BABY¿S TCPCO2 READING STABILIZED, AND A BLOOD GAS WAS REPEATED WHICH REFLECTED THE IMPR
Patient problems: Low Oxygen Saturation
MAUDE report 20527869 ↗
Other CATHETERS, SUCTION, TRACHEOBRONCHIAL devices
- Ballard* Closed Suction System 93826Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall70 reports
- Ballard* Closed Suction System 92431Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL78 reports
- Medline DYNCPDS14Medline Industries, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall16 reports
- Ballard* Turbo-Cleaning Closed Suction System 98965Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall16 reports
- Ballard* Turbo-Cleaning Closed Suction System 98263Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall11 reports
- Ballard* Closed Suction System for Adults 98310Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall1 death9 reports
- Medline DYNCPTP14TMedline Industries, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall6 reports
- Medline DYNCPTP14Medline Industries, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall4 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page