New Image 11703Recalls & reported problems
Hollister Incorporated · 2-Piece Ostomy Skin Barrier, Soft Convex, CeraPlus · Class 1
All models of New Image (19)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00610075069088), received between Nov 7, 2024 and Feb 4, 2025 — classified as 2 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Rash2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryFeb 4, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT SKIN IRRITATION DEVELOPED UNDER THE BARRIER OF THE HOLLISTER NEW IMAGE SOFT CONVEX OSTOMY BARRIER. IT WAS REPORTED THAT IT HAD BEEN GOING ON FOR SEVERAL MONTHS, NOT SPECIFIC TO ANY PARTICULAR LOT OF PRODUCT, AND HADN'T BEEN CLEARING UP. IT WAS FURTHER REPORTED THAT THEY DIDN'T REALIZE IT WAS FROM EFFLUENT SEEPING UNDER THE BARRIER IRRITATING THE SKIN. IT WAS REPORTED THAT THE END USER WENT TO A DERMATOLOGIST A FEW TIMES AND HE WAS PRESCRIBED A LIQUID TO USE UNDER THE BARRIER ON THE SKIN. IT WAS REPORTED THAT THE DERMATOLOGIST SAID THE SEEPING WAS PROBABLY FROM THE BARRIER NOT ADHERING WELL DUE TO THE PRESENCE OF A HERNIA AND SUGGESTED THEY TRY AN OSTOMY BELT. IT WAS REPORTED THAT THE LIQUID ON THE SKIN IS HELPING, AND THE SKIN IS NOW HEALING.
Patient problems: Rash
MAUDE report 21306702 ↗InjuryNov 7, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT SKIN IRRITATION DEVELOPED UNDER THE BARRIER OF THE HOLLISTER NEW IMAGE SOFT CONVEX OSTOMY BARRIER. IT WAS REPORTED THAT IT HAD BEEN GOING ON FOR A MONTH, NOT SPECIFIC TO ANY PARTICULAR LOT OF PRODUCT, AND HADN'T BEEN CLEARING UP. IT WAS FURTHER REPORTED THAT IT WAS DETERMINED TO BE A YEAST INFECTION AND NYSTATIN POWDER WAS PRESCRIBED FOR USE UNDER THE BARRIER. IT WENT ON TO REPORT THAT THE NYSTATIN POWDER TREATMENT BEGAN YESTERDAY, AND HE HAS NOT YET SEEN ANY IMPROVEMENT.
Patient problems: Rash
MAUDE report 20635810 ↗
Other COLLECTOR, OSTOMY devices
- New Image 11704Hollister Incorporated · COLLECTOR, OSTOMY4 reports
- New Image 14803Hollister Incorporated · COLLECTOR, OSTOMY3 reports
- New Image 11504Hollister Incorporated · COLLECTOR, OSTOMY2 reports
- New Image 14603Hollister Incorporated · COLLECTOR, OSTOMY2 reports
- New Image 11203Hollister Incorporated · COLLECTOR, OSTOMY2 reports
- Premier 8331Hollister Incorporated · COLLECTOR, OSTOMY2 reports
- Premier 8512Hollister Incorporated · COLLECTOR, OSTOMY1 report
- Premier 88400Hollister Incorporated · COLLECTOR, OSTOMY1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page