N/A 7756195Recalls & reported problems
Medtronic Sofamor Danek, Inc. · INSTRUMENT 7756195 SCRWDRVR 2.5MM HEX TH · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00613994207999), received between Jun 21, 2018 and Jun 21, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Device Slipped” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device Slipped1
Patient problems
- Bone Fracture(s)1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJun 21, 2018Device Slipped; Device Slipped
PRE-OPERATIVE DIAGNOSIS: CERVICAL SPONDYLOTIC MYELOPATHY DUE TO SYMPTOMATIC RECURRENCE. TYPE OF PROCEDURE: POSTERIOR CERVICAL DECOMPRESSION AND FUSION WITH DURAL SUTURE. IT WAS REPORTED THAT INTRA-OPERATIVELY WHEN THE PEDICAL SCREW WAS INSERTED IN C7 THROUGH CT NAVIGATION IT WAS OBSERVED WITH THE HELP OF C-ARM THAT IT WAS PENETRATING THE END PLATE OF CRANIAL SIDE AT C7 AND DEVIATED FROM PEDICAL SCREW. DUE TO WHICH THE SCREW DRIVER SLID AND TOUCHED THE DURA AND INJURY OF THE DURA OCCURRED. THEREAFTER ADDITIONAL SURGERY DURAL SUTURE WAS PERFORMED, SO THE SCREW WAS REMOVED. WHILE INSERTING THE SCREW AFTER DECOMPRESSION. A CRACK OCCURRED IN THE ARCH OF VERTEBRA. DUE TO WHICH THE SCREW WAS NOT INSERTED. THE SURGERY WAS DELAYED BY LESS THAN 60 MINUTE DUE TO THIS EVENT. BOTH THE IMPLANTS DID NOT COME IN CONTACT WITH THE PATIENT. NO BREAKAGE OF IMPLANTS OCCURRED DUE TO REPORTED EVENT. NO FRAGMENTS OF INSTRUMENTS WERE REMAINED IN PATIENT. PATIENT COMPLICATIONS WERE UNKNOWN WITH THE AVAILABLE INFORMATION. THE TIP OF THE DRIVER DID NOT FIT WITH THE SCREW AND SLIPPED DUE TO WHICH DURA INJURED AND DURAL SUTURE WAS PERFORMED.
Patient problems: Bone Fracture(s)
MAUDE report 7624947 ↗
Other SCREWDRIVER devices
- DELTA XTEND 2307-92-003Depuy (Ireland) · SCREWDRIVER751 reports
- EXPEDIUM 279712400Medos International Sàrl · SCREWDRIVER551 reports
- NA 314.467Synthes GmbH · SCREWDRIVER498 reports
- N/A 5584111Medtronic Sofamor Danek, Inc. · SCREWDRIVER492 reports
- QUICKSET 2274-47-000Depuy (Ireland) · SCREWDRIVER487 reports
- NA 03.130.010Synthes GmbH · SCREWDRIVER1 recall422 reports
- QUICKSET 2274-63-000Depuy (Ireland) · SCREWDRIVER404 reports
- EVOS 71175072Smith & Nephew, Inc. · SCREWDRIVER336 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page